Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
Parameter
Input Voltage Range
Input Frequency
Input Current, Full Load
Conditions
Universal
Inrush Current, Cold Start
Leakage Current
Power Factor Correction
Input Protection
Min.
90
47
Typ.
90 VAC
6
110 VAC
220 VAC
264 VAC
Meets EN 61000-3-2 Class D
T8A/250V Fuse
Max.
264
63
35
70
1.0
Units
VAC
Hz
A
A
mA
Output
Parameter
Output Voltage Adjustment
Output Regulation, See Note 1
Hold Time
Ripple & Noise (20 MHz), See Note 2
Overload Protection
Over Voltage Protection
Over Temperature Protection
Temperature Coefficient
Transient Recovery Time, See Note 4
Transient Response Deviation
Overshoot/Undershoot
Turn On Delay
Output Short Circuit
Conditions
Min.
By Trim Pot
Typ.
±5.0
±1.0
Max.
120 VAC, 80% Load
20
See Model Selection Guide
Foldback Circuit, Autorecovery
110
140
>130% of Rated Output Voltage. Recycle AC Input.
Autorecovery
+110
±0.04
2.5
50% Load Change
5
At Turn On/Off
±5.0
120 VAC
1
Continuous With Autorecovery
Units
%
%
mSec
%
ºC
%/ºC
mS
%
%
S
General
Parameter
Isolation Voltage, See Note 5
Switching Frequency
Conditions
Input - Output
Input - FG (Frame Ground)
Primary - Core
Fixed
Min.
3,000
1,500
1,500
Typ.
Max.
Units
VAC
23
kHz
Interface Signals
Power Supply On
Green LED on the PCB
An open collector output rated for 15V/5 mA sink current maximum.
Goes high if a fan failure is detected
Goes TTL high 100 to 500 mS after regulation. Goes low at least 1 mS
before the loss of regulation. Will sink 100 mA.
A TTL low signal inhibits the output. Hiccup mode.
Fan Fail
Power Good Signal
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T: (781) 344-8226
F: (781) 344-8481
E: [email protected]
W: www.micropowerdirect.com
Remote On/Off
Environmental
Parameter
Operating Temperature Range
Output Derating
Storage Temperature Range
Cooling
Operating Humidity
Conditions
Min.
Typ.
Max.
Units
0
+25
+70
ºC
2.5%/ ºC from +50 ºC to + 70 ºC
-20
+85
ºC
See Model Selection Guide
RH, Non-condensing
90
%
Ambient
Reliability Specifications
Parameter
MTBF
Safety Standards
EMI Compliance
EMS Immunity Compliance
Vibration
Conditions
Min.
Typ.
Max.
Units
MIL HDBK 217F, 30ºC, Gnd Benign
100
kHours
UL 60950, EN 60950
Compliance to EN 55022 (CISPR22) Class B; EN 61000-3-2,3
EN 6100-4-2,3,4,5,6,11; EN 55024; CE Marked (LVD)
Sinusoidal 5~50 Hz, Acceleration ±7.35 m/s2 on X, Y & Z Axis
www.micropowerdirect.com
www.micropowerdirect.com
Model Selection Guide
Output
Current
Max.
Output Voltage (VDC)
Output
W/ 26.85 CFM Power
PreSet
Range
Model
Number
Ripple
&
Efficiency
Noise
(%)
(Max A)
(W)
(% p-p)
MPU-400S-12YZ 12 VDC
10.0 - 13.8
33.33
400
±1%
85%
MPU-400S-24YZ 24 VDC
21.0 - 26.0
16.67
400
±1%
85%
MPU-400S-48YZ 48 VDC
43.0 - 50.0
8.33
400
±1%
85%
Notes:
1. Output regulation includes line & load.
2. Ripple & noise is measured from 10 Hz to 20 MHz. Connection to the unit is made with a 0.1 µF ceramic capacitor and
a 22 µF electrolytic capacitor connected in parallel.
3. A 1% minimum load is required to maintain regulation and
ripple specifications.
4. Transient recovery is measured to within a 1% error band
for a load step of 50% to 100%.
5. Isolation specifications are production HI-Pot tested for 3
seconds.
6. The full output range (see table) is covered in the safety
agency certification. Standard models are factory set to
the Preset voltage, but may be set to other levels within the
Model Number
range without affecting the agency certification. For more information,
contact the factory.
7. Output power is given for the factory preset voltage. The maximum
continuous output power level is 220W without providing 26.85 CFM
airflow. All models provide a peak power level of 700W for a maximum
duration of 500 µS. For more information, contact the factory.
8. Each unit includes an input fuse (T8A/250V). Since this fuse is not field
replaceable, it is recommended that an external fuse of the same size
be used on the input of the power supply for protection.
Models with other output voltage levels
are available (i.e. 15 VDC, 36 VDC, etc)
Contact the factory for details at:
[email protected]
Mechanical Dimensions (Shown With Terminal Strip)
Connections
Input/Output Connector (CN1):
• Terminal Block:
Howder No. HB-95-7P
7 pins, M3.5 Screw, 9.5 mm Centers
• JST Mating Part No:
VHR5N or equivalent (two pins removed)
VHR10N
Crimp Terminals: SVH41T-P1.1
Pin T Block
1
+VOUT
2
+VOUT
3
-VOUT
4
-VOUT
5 Field Grnd
6 AC-Neutral
7
AC-Line
Pin
1
2
3
4
5
6
7
8
9
10
JST
+VOUT
+VOUT
+VOUT
+VOUT
+VOUT
-VOUT
-VOUT
-VOUT
-VOUT
-VOUT
1
3
5
Field Grnd
AC-Neutral
AC-Line
Logic Signal Connector (CN2):
• JST Mating Part No:
XHP-4 or equivalent
• Mating Pins: JST SXH-002T-PO.6
For AWG 30 to 26
U-Chassis Cover (C Suffix, Shown With JST Connector)
Pin
Function
1
2
3
4
Remote On/Off
Fan Fail
Common
Power Good
Fan Driver Connector (CN3):
• JSTMating Part No:
JST XHP-2 or equivalent
• Mating Pins: JST SXH-002T-PO.6
Pin
Function
1
2
Plus
Minus
MicroPower Direct
Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = ±0.02 (±0.50)
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: [email protected]