MPA150 Series Compact 1U 150W Single Output Power Factor Corrected AC/DC Power Supplies Key Features: • Compact 1U 150W Supply • PFC to EN61000-3-2 “A” • UL, cUL, TUV Approvals • CE Certified • FCC Class B Emissions • 3 - 56 V Output Voltages • Auto Selectable AC Input • 600W Peak Power • Four Mechanical Options Only 5 x 3.2 x 1.5 in!! Electrical Specifications Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice notice. Input Parameter Input Voltage Range Conditions Autoranging Input Frequency Input Current, Full Load Inrush Current, Cold Start Leakage Current Power Factor Correction Input Protection Min. 90 180 47 Typ. 110 - 120 VAC 4 200 - 240 VAC 2 110 VAC 220 VAC 240 VAC 1.5 Meets EN61000-3-2 Class A T4A/250V Fuse Max. 132 264 63 Units VAC Hz A 35 70 A mA Output Parameter Output Voltage Adjustment Output Regulation (Note 1) Hold Time Ripple & Noise (20 MHz) (Note 2) Overload Protection Over Voltage Protection Over Temperature Protection Temperature Coefficient Transient Recovery Time (Note 3) Transient Response Deviation Overshoot/Undershoot Turn On Delay Output Short Circuit Conditions Min. Typ. Max. ±5.0 ±1.0 110 VAC, 80% Load 20 See Model Selection Guide Foldback with Autorecovery 110 140 >130% of Rated Output Voltage. Recycle AC Input. >+85ºC Ambient with Autorecovery ±0.04 2.5 50% Load Change 5 At Turn On/Off ±5.0 120 VAC 1 Continuous With Autorecovery By Trim Pot Units % % mSec % %/ºC mS % % S General Parameter Isolation Voltage (Note 4) Switching Frequency MicroPower Direct Interface Signals 292 Page Street Suite D Stoughton, MA 02072 USA T: (781) 344-8226 F: (781) 344-8481 E: [email protected] W: www.micropowerdirect.com Power Supply On Power Good Signal Remote On/Off Conditions Input - Output Input - FG (Frame Ground) Primary - Core Fixed Min. 3,000 1,500 1,500 Typ. Max. Units VAC 25 kHz Green LED (LED1) on the PCB PG on CN1. Goes TTL high 100 to 500 mS after regulation. Goes low at least 1 mS before the loss of regulation. Will sink 100 mA. RMSW on CN1. A TTL low signal inhibits the output. Hiccup Mode Environmental Parameter Operating Temperature Range Output Derating Storage Temperature Range Cooling Operating Humidity Conditions Min. Typ. Max. Ambient 0 +25 +50 2.5%/ ºC from +50 ºC to + 70 ºC -20 +85 See Model Selection Guide RH, Non-condensing 90 Units ºC ºC % Reliability Specifications Parameter MTBF Safety Standards EEMI Compliance EMS Immunity Compliance Conditions Min. Typ. Max. Units MIL HDBK 217F, 30ºC, Gnd Benign 100 kHours UL 60950; CSA C22.2 No. 60950; TUV EN60950; CB Report (IEC 60950) Compliance to EN55022 (CISPR22) Class B; EN61000-3-2,3 EN6100-4-2,3,4,5,6,8,11; EN55024,; CE Marked (LVD) Model Selection Guide Model Number MPA150x-03z MPA150x-05z MPA150x-12z MPA150x-18z MPA150x-24z MPA150x-48z Output Voltage Factory Range PreSet 3.3 VDC 3.0 - 4.0 VDC 5 VDC 5.0 - 6.0 VDC 12 VDC 12.0 - 16.0 VDC 18 VDC 17.0 - 23.0 VDC 24 VDC 24.0 - 30.0 VDC 48 VDC 35.0 - 56.0 VDC Max. Output Current (Note 5,6,7) 16 CFM Convection Min. (U/w Air, F) 30.00A 30.00A 12.50A 8.33A 6.25A 3.12A Notes: 1. Output regulation includes line & load. 2. Ripple & noise is measured from 10 Hz to 20 MHz. Measurement connection to the unit is made with a 0.1 µF ceramic capacitor & a 22 µF electrolytic capacitor connected in parallel. 3. Transient recovery is measured to within a 1% error band for a load step change of 50% to 100%. 4. Isolation specifications are production HI-Pot tested for 3 seconds. (U) 20.00A 20.00A 8.33A 5.55A 4.16A 2.08A 0.0A 0.0A 0.0A 0.0A 0.0A 0.0A Ripple & Noise Efficiency 50 mV p-p 50 mV p-p ±1% p-p ±1% p-p ±1% p-p ±1% p-p 70% 75% 80% 83% 83% 83% Input Connector CN3: Mating Molex Part No. 09-91-0500 (5 pin, 3 used) or Howder Terminal Block No. HD-603-3P (3-pin) or equivalent. (Note 7) Output Connector CN2: Mating Molex Part No. 09-91-0600 (6 pin) or Howder Terminal Block No. HD-601-4P (4-pin) or equivalent. Output Pin Assignment: 5. The full output range (see table above) is covered in the safety agency certification. Standard models are factory set to the “Preset” voltage. This may be set to other levels within the range without affecting the agency certification. For more information, contact the factory. 6. Units will provide peak power of 600W for 500 µS. For units capable of longer durations, contact the factory. 7. A 1% minimum load is required to maintain regulation and ripple specifications. Howder Molex Pins 1 ~ 2: V+ Pins 1 ~ 3: V+ Pins 3 ~ 4: V- Pins 4 ~ 6: V- Logic Signal Connector CN1: Mating JST XHP-3 or equivalent (CHYAO SHIUNN JS-2001-03). Fan driver connector (FAN): 12 VDC / 300 mA is available to drive an external fan. Mating JST XHP-2 or equivalent (CHYAO SHIUNN JS-2001-02). Mechanical Dimensions: U-Chassis (U Suffix) U-Chassis Cover (C Suffix) U-Chassis Cover/W Fan (F Suffix) U-Chassis Alternate Cover (B Suffix) MicroPower Direct www.micropowerdirect.com 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: [email protected]