MPD MPA800RX-48ZZ

MPA800R Series
Industrial 800W
Single Output
Power Factor Corrected
AC/DC Power Supplies
Key Features:
• 800W Output Power
• Universal 90-264 VAC Input
• PFC to EN61000-3-2 “D”
• UL, cUL, TUV Approvals
• CE Certified
• FCC Class B Emissions
• 12 - 60 V Output Voltages
• N+1 Current Share Option
• Three Mechanical Options
Low Cost
Industrial
Power!!
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change
h
without
h
notice.
Input
Parameter
Input Voltage Range
Input Frequency
Under Voltage Shutdown
Input Current, Full Load
Inrush Current, Cold Start
Leakage Current (Note 2)
Power Factor Correction
Input Protection
Conditions
Min.
Typ.
Max.
90
264
47
63
See Note 1
200 - 240 VAC
6
230 VAC
70
240 VAC
3.5
Active, Meets EN61000-3-2 Class D
T10A/250V Fuse
Units
VAC
Hz
A
A
mA
Output
Parameter
Output Voltage Adjustment
Output Regulation (Note 3)
Hold Time
Ripple & Noise (20 MHz) (Note 4)
Overload Protection
Over Voltage Protection
Over Temperature Protection
Temperature Coefficient
Transient Recovery Time (Note 5)
Transient Response Deviation
Overshoot/Undershoot
Turn On Delay
Output Short Circuit
Conditions
Min.
Typ.
Max.
±5.0
±1.0
220 VAC, 80% Load
20
See Model Selection Guide
Foldback Mode
110
140
>130% of Rated Output Voltage. Recycle AC Input.
>+85ºC Ambient with Autorecovery
±0.04
2.5
50% Load Change
5
At Turn On/Off
5.0
120 VAC
1
Continuous With Autorecovery
By Trim Pot
Units
%
%
mSec
%
%/ºC
mS
%
%
S
General
Parameter
Isolation Voltage
Switching Frequency
Conditions
Input - Output
Input - FG (Frame Ground)
Primary - Core
Fixed
Min.
3,000
1,500
1,500
Typ.
Max.
Units
VAC
23
kHz
Interface Signals
Power Supply On
Power Good Signal
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T: (781) 344-8226
F: (781) 344-8481
E: [email protected]
W: www.micropowerdirect.com
Current Sharing
Current Monitor
Remote Sense
Remote On/Off
Green LED (LED1) on the PCB
PG on CN3. Goes TTL high 100 to 500 mS after regulation. Goes low at
least 1 mS before the loss of regulation. Will sink 100 mA.
CSH on CN3. Single wired, forced current sharing option. Up to four
units may be connected in parallel within 10% accuracy at full load.
CMN on CN3. A 0.5V to 3.0V output that represents 0% to 100% of the
unit output current
RS + and RS- on CN3. Compensates for up to a 0.5V line drop. (not on
models with current share option)
RSW on CN3. A TTL low signal inhibits the output
Environmental
Parameter
Operating Temperature Range
Output Derating
Storage Temperature Range
Cooling
Operating Humidity
Vibration
Conditions
Min.
Typ.
Max.
Units
Ambient
0
+25
+50
ºC
2.5%/ ºC from +50 ºC to + 70 ºC
-20
+85
ºC
See Model Selection Guide
RH, Non-condensing
90
%
Frequency 5~50 Hz, Acceleration 7.35 m/(S x S) on X, Y & Z Axis
Reliability Specifications
Parameter
MTBF
Safety Standards
EMI Compliance
EMS Immunity Compliance
Conditions
Min.
Typ.
Max.
Units
MIL HDBK 217F, 30ºC, Gnd Benign
150
kHours
UL 60950; CSA C22.2 No. 60950; TUV EN60950; CB Report (IEC 60950)
Compliance to EN55022 (CISPR22) Class B; EN61000-3-2,3
EN6100-4-2,3,4,5,6,8,11; EN55024,; CE Marked (LVD)
Model Selection Guide
Model
Number
MPA800Rx-12zz
MPA800Rx-15zz
MPA800Rx-24zz
MPA800Rx-36zz
MPA800Rx-40zz
MPA800Rx-48zz
Output Voltage
Factory
Range (Note 6)
PreSet
12 VDC 12.0 - 14.0 VDC
15 VDC 15.0 - 19.0 VDC
24 VDC 20.0 - 26.0 VDC
36 VDC 27.0 - 36.0 VDC
40 VDC 37.0 - 47.0 VDC
48 VDC 48.0 - 60.0 VDC
Output Current (Notes 7, 8, 9)
(“U” units) Max.
“E” Units
Min
with 30 CFM
Int. Fan
62.50A
0.0A
62.50A
50.00A
0.0A
50.00A
40.00A
0.0A
40.00A
29.63A
0.0A
29.63A
21.62A
0.0A
21.62A
16.67A
0.0A
16.67A
Notes:
1. If the input voltage drops below 80 VAC ±5 VAC, the unit power will
shut down. When the input voltage rises above 86 VAC , the unit will
recover automatically.
2. Models are available with leakage current specified as low as 750 µA.
Contact the factory for details.
3. Output regulation includes line & load.
4. Ripple & noise is measured from 10 Hz to 20 MHz. Measurement
connection to the unit is made with a 0.1 µF ceramic capacitor & a 22
µF electrolytic capacitor connected in parallel.
Ripple &
Noise
Efficiency
1% p-p
1% p-p
1% p-p
1% p-p
1% p-p
1% p-p
(Note 7)
80%
83%
83%
83%
83%
83%
5. Transient recovery is measured to within a 1% error band for a load step change of 50%
to 100%.
6. The full output range (see table above) is covered in the safety agency certification. Standard models are factory set to the “Preset” voltage. This may be set to other levels within
the range without affecting the agency certification. Contact the factory for details.
7. A minimum load of 1% is required to maintain load regulation and ripple specifications.
8. Output current is given for the factory preset voltage. With the exception of the “12”
(750W) output model, the maximum continuous output power level is 800W with 30
CFM. For more information, contact the factory.
9. Units will provide peak power of 900W for 500 µS. For units capable of longer durations,
contact the factory.
Input Connector CN1:
U-Chassis (U,C)
Howder Terminal Block No. HD-121-3P (3-pin) or
Mating Molex Part No. 09-91-0700 (7 pin, 5 used)
or equivalent.
Enclosed with Fan (E)
Dinkle Terminal Block No. DT-35-A02W-3 (3-pin) or
IEC 320 or equivalent snap-in mounting type.
Output Connector CN2:
Howder Terminal Block No. HD-121-8P (8-pin) or
Mating Molex Part No. 09-91-2000 (20 pin) or
equivalent.
Output Pin Assignment:
Howder
Molex
Pins 1 ~ 4: V+
Pins 1 ~ 10: V+
Pins 5 ~ 8: V-
Pins 11 ~ 20: V-
Logic Signal Connector CN3:
Mating JST XHP-7 or equivalent (CHYAO
SHIUNN JS-2001-07).
Fan driver connector (FAN):
12 VDC / 500 mA is available to drive an
external fan. Mating JST XHP-2 or equivalent (CHYAO SHIUNN JS-2001-02).
Mechanical Dimensions: U-Chassis (U Suffix)
Enclosure With Fan (E Suffix)
U-Chassis Cover (C Suffix)
MicroPower Direct
www.micropowerdirect.com
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: [email protected]