MPU-800E Datasheet - Micropower Direct

MPU-800E Series
Single Output 800W
Power Factor Corrected
AC/DC Power Supplies
Electrical Specifications
Key Features:
• Compact 800W Supply
• PFC to EN 61000-3-2 “D”
• EN 60950 Approved (UL)
• CE Certified
• FCC Class B Emissions
• Universal AC Input
• Current Share Option
• Compact Case w/End Fan
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
Parameter
Input Voltage Range
Input Frequency
Input Current, Full Load
Conditions
Universal
Inrush Current, Cold Start
Leakage Current
Power Factor Correction
Input Protection
Input Undervoltage Protection
Min.
90
47
Typ.
Max.
264
63
Units
VAC
Hz
A
90 VAC
12.0
110 VAC
35
A
220 VAC
70
264 VAC
2.0
mA
Meets EN 61000-3-2 Class D
T10A/250V Fuse
Under 80 VAC ±5 VAC Unit Shuts Down; Unit Recovers Over 86 VAC
Output
Parameter
Output Voltage Adjustment
Output Regulation, See Note 1
Hold Time
Ripple & Noise (20 MHz), See Note 2
Overload Protection
Over Voltage Protection
Over Temperature Protection
Temperature Coefficient
Transient Recovery Time, See Note 4
Transient Response Deviation
Overshoot/Undershoot
Turn On Delay
Output Short Circuit
Conditions
Min.
By Trim Pot
Typ.
±5.0
±1.0
Max.
120 VAC, 80% Load
20
See Model Selection Guide
Foldback Circuit, Autorecovery
110
140
>130% of Rated Output Voltage. Recycle AC Input.
Autorecovery
+85
±0.04
2.5
50% Load Change
5.0
At Turn On/Off
±5.0
230 VAC
1.0
Continuous With Autorecovery
Units
%
%
mSec
%
ºC
%/ºC
mS
%
%
S
General
Parameter
Isolation Voltage, See Note 5
Switching Frequency
Conditions
Input - Output
Input - FG (Frame Ground)
Primary - Core
Fixed
Min.
3,000
1,500
1,500
Typ.
Max.
Units
VAC
24
kHz
Interface Signals
LED Power Supply On
Current Monitor
Current Share
Remote Sense
Bi-color LED Is Green For Power On; Orange When Protection Enabled
A 0.5 to 3.0V Output That Represents 0% to 100% Output Current
Optional For Sharing Up To Four Units. Contact The Factory For Details
Compensates For Up To A 0.5V Line Drop
Goes TTL high 100 to 500 mS after regulation. Goes low at least 1 mS
before the loss of regulation. Will sink 100 mA.
A TTL low signal inhibits the output. Hiccup mode.
Power Good Signal
MicroPower Direct
Remote On/Off
292 Page Street
Suite D
Stoughton, MA 02072
USA
Environmental
T: (781) 344-8226
F: (781) 344-8481
E: [email protected]
W: www.micropowerdirect.com
Parameter
Operating Temperature Range
Output Derating
Storage Temperature Range
Cooling
Operating Humidity
Conditions
Min.
Typ.
Max.
Units
0
+25
+70
ºC
2.5%/ ºC from +50 ºC to + 70 ºC
-20
+85
ºC
See Model Selection Guide
RH, Non-condensing
90
%
Ambient
Reliability Specifications
Parameter
MTBF
Safety Standards
EMI Compliance
EMS Immunity Compliance
Vibration
Conditions
Min.
Typ.
Max.
Units
MIL HDBK 217F, 30ºC, Gnd Benign
100
kHours
UL 60950, EN 60950
Compliance to EN 55022 (CISPR22) Class B; EN 61000-3-2,3
EN 6100-4-2,3,4,5,6,11; EN 55024, CE Marked (LVD)
Sinusoidal 5~50 Hz, Acceleration ±7.35 m/s2 on X, Y & Z Axis
www.micropowerdirect.com
www.micropowerdirect.com
Model Selection Guide
Model
Number
Output Voltage (VDC)
PreSet
Range
Max.
Output
Power
Output
Current
(Max A)
Ripple
& Noise Efficiency
(%)
(% p-p)
(W)
MPU-800S-12YYEI
12 VDC 12.0 - 15.0
62.50
800
±1%
80%
MPU-800S-24YYEI
24 VDC 22.0 - 30.0
40.00
800
±1%
83%
MPU-800S-48YYEI
48 VDC 48.0 - 56.0
16.67
800
±1%
83%
Models with other output voltage levels
are available (i.e. 15 VDC, 36 VDC, etc)
Contact the factory for details at:
[email protected]
Model Number
Notes:
1. Output regulation includes line & load.
2. Ripple & noise is measured from 10 Hz to 20 MHz. Connection to the unit is made with a 0.1 µF ceramic capacitor & a
22 µF electrolytic capacitor connected in parallel.
3. A 1% minimum load is required to maintain regulation & ripple specifications.
4. Transient recovery is measured to within a 1% error band for a load step change of 50% to 100%.
5. Isolation specifications are production HI-Pot tested for 3 seconds.
6. The full output range (see table) is covered in the safety agency certification. Standard models are factory set to the Preset
voltage, but may be set to other levels within the range without affecting the agency certification. For more information,
contact the factory.
7. Output power is given for the factory preset voltage. The maximum continuous output power level is 800W. All models
provide a peak power level of 900W for a maximum duration of 500 µS. For more information, contact the factory.
8. Each unit includes an input fuse (250V/12A). Since this fuse is not field replaceable, it is recommended that an external
fuse of the same size be used on the input of the power supply for protection.
Mechanical Dimensions
Connections
Input Connector (CN1):
• Terminal Block:
Dinkle DT-35-A02W-03 (3Pin)
M3 Screws, 8.25 mm Centers
• IEC320 or equivalent
Pin
Function
1
2
3
AC-Line
AC-Neutral
Field Ground
Output Connector (CN2):
• Terminal Block:
Howder HD-121-8P: M3.5 Screws
8 pins, 9.5 mm Centers
• Molex Mating Part No:
Molex 09-91-2000 or equivalent
Howder
Logic Signal Connector (CN3):
• Mating Part No:
JST XHP-7 or equivalent
(CHYAO SHIUNN JS-2001-07)
Molex
Pin
Function
Pin
Function
1-4
5-8
-VOUT
+VOUT
1-10
11-20
-VOUT
+VOUT
Pin
Function
1
2
3
4
5
6
7
+ Remote Sense
- Remote Sense
Remote On/Off
Power Good
Common
Current Share
Current Monitor
MicroPower Direct
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
Input IEC320 Connector (Optional)
Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = ±0.02 (±0.50)
FAX: (781) 344-8481
•
E-Mail: [email protected]