MPL-03SE Datasheet - Micropower Direct

MPL-03SE Series
Single Output, 3W
Ultra-Miniature SIP
AC/DC Power Supplies
Key Features:
Electrical Specifications
• 3W Output Power
• Universal 85-264 VAC Input
• EN 60950 Approved
• Meets IEC Safety Class II
• Right Angle Pins Available
• Single Regulated Output
• Meets EN 55022 Class A
• >300 kHour MTBF
• Ultra-Miniature “SIP” Case
Specifications typical @ +25°C, 230 VAC input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
Parameter
Conditions
Input Voltage Range
Input Frequency
Input Current
Inrush Current
Min.
Typ.
85
100
47
See Model Selection Guide
115 VAC
20.0
230 VAC
40.0
Max.
264
400
440
Units
VAC
VDC
Hz
Conditions
Min.
Typ.
See Model Selection Guide
Max.
Units
0.5
W
A Pk
Output
Parameter
Output Voltage Accuracy
Standby Power Consumption
3.3 VOUT Model
VIN = MIN to MAX
All Other Models
IOUT = 10% to 3.3 VOUT Model
100% All Other Models
3.3, 5 VOUT Models
All Other Models
115 VAC
230 VAC
Line Regulation
Load Regulation
Ripple & Noise (20 MHz)
Hold-Up Time
Temperature Coefficient
Over Current Protection
Short Circuit Protection
±0.5
±1.5
±1.5
±2.5
70
50
%
%
mV P-P
60
300
msec
±0.02
110
Continuous (Autorecovery)
140
%/°C
%IOUT
General
Parameter
Isolation Voltage
Isolation Resistance
Switching Frequency
EMI Characteristics
Parameter
Radiated Emissions
Conducted Emissions
ESD
RS
EFT
Surge
CS
PFM
Voltage Dips
Conditions
Input to Output
500 VDC
3.3 VOUT Model
All Other Models
Min.
3,000
100
Standard
See Note 2
EN 55022
See Note 2
EN 55022
EN 61000-4-2
See Note 3
EN 61000-4-3
See Note 4
EN 61000-4-4
See Note 4
EN 61000-4-4
See Note 5
EN 61000-4-5
See Note 6
EN 61000-4-6
EN 61000-4-8
EN 61000-4-11
Min.
Typ.
Max.
100
50
Units
VAC
M
kHz
Typ.
Max.
Units
Class A
Class A
Criteria B; ±4 kV Contact
Criteria A; 10V/m
Criteria B; ±2 kV
Criteria B; ±4 kV
Criteria B; ±1 kV /±2 kV
Criteria A; 3 Vrms
Criteria A; 10A/m
Criteria B; 0% - 70%
Environmental
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T: (781) 344-8226
F: (781) 344-8481
E: [email protected]
W: www.micropowerdirect.com
Parameter
Operating Temperature Range
Operating Temperature Range
Storage Temperature Range
Cooling
Humidity
Conditions
Max.
+85
+90
-40
+105
Free Air Convection (See Derating Curve)
RH, Non-condensing
85
Ambient
Surface (Case)
Min.
-40
Typ.
+25
Units
°C
°C
°C
%
Physical
Case Size
Case Material
Weight
Wave Soldering (5 - 10s)
Manual Soldering (3 - 5s)
Solder Temperature
See Mechanical Drawings (Page 4)
Non-Conductive Epoxy (UL94-V0)
0.28 Oz (8g)
255
260
265
°C
350
360
370
Reliability Specifications
Parameter
MTBF
Safety Standards
Safety Class
Conditions
Min.
Typ.
MIL HDBK 217F, 25°C, Gnd Benign
300
EN 60950
IEC 61140 Class II
www.micropowerdirect.com
Max.
Units
kHours
www.micropowerdirect.com
Model Selection Guide
Input
Model
Number
Output
Current (A Max.)
Voltage
Current
(mA Max.)
Maximum
Output
Power
Output
Voltage
Accuracy
Capacitive
Load
(µF, Max)
Efficiency
(%, Typ)
Fuse Rating
Slow-Blow
115 VAC
230 VAC
(VDC)
(W)
(%)
MPL-03S-03E(F)
0.120
0.060
3.3
500
1.65
±3.0
2,300
66
1.0A/250 VAC
MPL-03S-05E(F)
0.120
0.060
5.0
500
2.50
±5.0
470
69
1.0A/250 VAC
MPL-03S-09E(F)
0.120
0.060
9.0
333
3.00
±8.0
150
76
1.0A/250 VAC
MPL-03S-12E(F)
0.120
0.060
12.0
250
3.00
±8.0
100
78
1.0A/250 VAC
MPL-03S-15E(F)
0.120
0.060
15.0
200
3.00
±5.0
100
78
1.0A/250 VAC
MPL-03S-24E(F)
0.120
0.060
24.0
125
3.00
±5.0
100
78
1.0A/250 VAC
Notes:
1. Operation at no load will not damage the units, however, they may not meet all specifications.
2. The External capacitors (C1 & C3) shown in the typical connection diagrams on page 3 are required to meet specified operation.
3. All units will meet EN 55022 (CE/RE) class A with the input circuit shown in the “Typical Connection 1” diagram on page 3. The MPL03SE will meet class B with the additional filtering shown in the
“Typical Connection 2” diagram on page 3. MPD offers filter modules that will save on board space and make the input filter design easier. Contact the factory for more information.
3. To meet the requirements of EN 61000-4-3, (10V/m) external filtering (as shown in the “Typical Connection 2” diagram on page 3) is required. This filtering may be added discretely, or by using a
filter module from MPD. Contact the factory for more information.
4. All units will meet EN 61000-4-4 (±2 kV) with the input circuit shown in the “Typical Connection 1” diagram on page 3. To meet the requirements of EN 61000-4-4 (±4 kV), external components
(as shown in the “Typical Connection 2” diagram on page 3) are required. This filtering may be added discretely, or by using a filter module from MPD. Contact the factory for more information.
5. All units will meet the requirements of EN 61000-4-5 (±1 kV/±2 kV), with the input circuit shown in the “Typical Connection 2” diagram on page 3. This filtering may be added discretely, or by using
a filter module from MPD. Contact the factory for more information.
6. All units will meet the requirements of EN 61000-4-6 (3V rms), with the input circuit shown in the “Typical Connection 2” diagram on page 3. This filtering may be added discretely, or by using a
filter module from MPD. Contact the factory for more information.
7. It is recommended that a fuse be used on the input of a power supply for protection. For the MPL-03SE(F) series, a 1.0A/250 VAC slow blow should be used.
8. The MPL-03SE(F) is available with the pins factory set to a 90° angle (see mechanical diagrams on page 4). To order units with this modification, add an “F” to the model number
(i.e. MPL-03S-12EF).
Derating Curve, Output Power vs Temperature
Derating Curve, Output Power vs Input Voltage
Efficiency vs Input Voltage VAC Input
Efficiency vs Input Voltage VDC Input
292 Page Street Ste D Stoughton, MA 02072
• TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: [email protected]
www.micropowerdirect.com
Typical Connection 1
The diagram above illustrates a typical connection of the MPL-03SE series. With this connection, the unit will meet EN 55022 class A, EN 61000-4-2 (±4kV), EN61000-4-4 (±2kV), EN 61000-4-8 and EN
61000-4-11. Components C1 and C3 are required to meet specified operation limits. The recommended input components are a 5D-9 (NTC), S10K300 (MOV1) and 5 mH (LIN). The recommended output component
values are given in the table below.
Typical Connection 2: With External EMC Components
For applications that require meeting higher EMC standards, the circuit shown above is recommended. Some notes
on this diagram (starting with the input circuit) are:
1. It is recommended that an external fuse be used. The recommended fuse is 1A/250V.
2. The capacitors CX and CYx are “safety” capacitors.
3. Capacitor C1 is a filter component. This capacitor is required to meet specified operation. It should be a high
frequency, low ESR electrolytic capacitor. The recommended value is given in the table below.
4. Capacitors C2 and C3 are output filter components. Capacitor C3 is required to meet specified operation. Low ESR,
high frequency electrolytic capacitors should be used. The recommended values are given in the table below.
5. Recommended values for components are:
Model
Number
MOV
LCM
Cx
LDM
CY2/CY3
6. The output TVS will help protect system circuitry if power supply fails. A recommended value is given in
the table below.
7. Capacitor C4 is ceramic. This capacitor is used to filter high frequency noise. A recommended value is
given in the table below.
8. All of the components within the dotted lines of the input EMC circuit are included in a filter module
available from MPD. Please contact the factory for more information.
External Components
C1
CY1
(Required)
C2
LOUT
S10k300
3.5 mH
0.1 μF/275 VAC
5 mH
1 nF/400 VAC
22 μF/400V
2.2 μH
1 nF/400 VAC
150 μF/35V
MPL-03S-15E
100 μF/35V
MPL-03S-24E
68 μF/35V
TVS
SMBJ7.0A
330 μF/25V
MPL-03S-05E
MPL-03S-09E
C4
120 μF/25V
MPL-03S-03E
MPL-03S-12E
C3
(Required)
0.1 μF/50V
SMBJ12A
SMBJ20A
SMBJ30A
Typical Board Layout: With External EMC Components
The diagram above shows a typical board layout for the MPL-03SE with the recommended EMI components shown in the “Typical Connection 2” diagram. Filter modules are available from MPD. Contact the factory for more information.
To meet safety regulations, the board trace widths should be >3 mm, the distance between traces should be >6 mm, and the distance between traces and ground should be >6 mm. The distance “A” noted on the drawing should
be >6.4 mm.
MicroPower Direct
•
292 Page Street Ste D Stoughton, MA 02072
• TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: [email protected]
www.micropowerdirect.com
Standard Models
Mechanical Dimensions, 3.3V Output Model
Mechanical Dimensions, All Other Models
Right Angle Pin Models
Mechanical Dimensions, 3.3V Output Model
Mechanical Dimensions, All Other Models
Pin Connections
Pin
Function
Pin
Function
1
3
5
AC-Neutral
AC-Line
+VCAP
7
10
12
-VCAP
-VOUT
+VOUT
For the “Right Angle” pins option, add suffix “F” to the
model number (i.e. MPL-03S-12EF)
Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = ±0.02 (±0.50)
MicroPower Direct
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: [email protected]