MDCFM-01A Datasheet

MDCFM-01A
Encapsulated DC
Surge Suppresion
EMC Filter Module
Key Features:
• 0 to 40 VDC Input
• Compact Case
• 30 dB Attenuation
• -40°C to +85°C Operation
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
Parameter
Input Voltage Range
Nominal Current
DCR
• Chassis Mount Option
General
• DIN Rail Mount Option
Parameter
Frequency Attenuation
• Low Cost
Conditions
See Note 1
See Note 2
Min.
0.0
Typ.
Max.
40.0
0.6
600
Conditions
Surge
EN 61000-4-5
Units
VDC
A
m⍀
Min.
Typ.
Max.
Units
30
dB
Criteria B; ±2 kV (2⍀ Internal Res.)
Criteria B; ±4 kV (12⍀ Internal Res.)
Environmental
Parameter
Operating Temperature Range
Storage Temperature Range
Cooling
Humidity
Physical
Conditions
Min.
Typ.
-40
+25
-55
Free Air Convection
RH, Non-condensing
Ambient
Module
Chassis (A2) Mount
DIN (A4) Mount
Case Size
Case Material
Module
Chassis (A2) Mount
DIN (A4) Mount
Weight
Notes:
1. The Max input voltage level of the DC/DC converter must be
less than the maximum specified input of the MDCFM-01A.
2. The Max input current of the DC/DC converter must be
less than the maximum specified nominal current of the
MDCFM-01A.
292 Page Street
Suite D
Stoughton, MA 02072
USA
Units
°C
°C
95
%
See Mechanical Drawing (Page 2)
See Mechanical Drawing (Page 2)
See Mechanical Drawing (Page 2)
Non-Conductive Black Plastic (UL94-V0)
0.53 Oz (15g)
1.24 Oz (35g)
1.95 Oz (55g)
Schematic: MDCFM-1A
The MDCFM-01 noise suppression modules
operate with many MPD standard DC/DC
converters.
MicroPower Direct
Max.
+85
+125
When connected to the input, these modules
will substantially improve the EMS performance of the converter. When used on the
output, they will substantially reduce the
converter output noise and ripple. Contact the
factory for more information
Typical Connection
T: (781) 344-8226
F: (781) 344-8481
E: [email protected]
W: www.micropowerdirect.com
www.micropowerdirect.com
www.micropowerdirect.com
Mechanical Dimensions
Pin Connections
Pin
1
2
3
4
Function
-VIN
+VIN
+VOUT
-VOUT
Mechanical Dimensions: With Chassis Mount Option (A2)
The MDCFM-01A is available mounted on an adapter plate for mounting to a
chassis or on a DIN rail. Mechanical dimensions for these adapters are shown at right.
The photo below shows a product mounted on a similar adapter. Please contact the
factory for more information.
For the chassis mount option, add suffix “A2” to the
model number (i.e. MDCFM-01A-A2)
For the DIN rail mount option, add suffix “A4” to the
model number (i.e. MDCFM-01A-A4)
Pin Connections
Mechanical Dimensions: With DIN Rail Option (A4)
Pin
Function
1
-VIN
2 No Connection
3
+VIN
4
+VOUT
5
-VOUT
Connection is the
same for A2 & A4
MicroPower Direct
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = ±0.02 (±0.50)
• Wire range for A2 & A4 connection is 24 - 12 AWG
FAX: (781) 344-8481
•
E-Mail: [email protected]