MDCFM-01A Encapsulated DC Surge Suppresion EMC Filter Module Key Features: • 0 to 40 VDC Input • Compact Case • 30 dB Attenuation • -40°C to +85°C Operation Electrical Specifications Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice. Input Parameter Input Voltage Range Nominal Current DCR • Chassis Mount Option General • DIN Rail Mount Option Parameter Frequency Attenuation • Low Cost Conditions See Note 1 See Note 2 Min. 0.0 Typ. Max. 40.0 0.6 600 Conditions Surge EN 61000-4-5 Units VDC A m⍀ Min. Typ. Max. Units 30 dB Criteria B; ±2 kV (2⍀ Internal Res.) Criteria B; ±4 kV (12⍀ Internal Res.) Environmental Parameter Operating Temperature Range Storage Temperature Range Cooling Humidity Physical Conditions Min. Typ. -40 +25 -55 Free Air Convection RH, Non-condensing Ambient Module Chassis (A2) Mount DIN (A4) Mount Case Size Case Material Module Chassis (A2) Mount DIN (A4) Mount Weight Notes: 1. The Max input voltage level of the DC/DC converter must be less than the maximum specified input of the MDCFM-01A. 2. The Max input current of the DC/DC converter must be less than the maximum specified nominal current of the MDCFM-01A. 292 Page Street Suite D Stoughton, MA 02072 USA Units °C °C 95 % See Mechanical Drawing (Page 2) See Mechanical Drawing (Page 2) See Mechanical Drawing (Page 2) Non-Conductive Black Plastic (UL94-V0) 0.53 Oz (15g) 1.24 Oz (35g) 1.95 Oz (55g) Schematic: MDCFM-1A The MDCFM-01 noise suppression modules operate with many MPD standard DC/DC converters. MicroPower Direct Max. +85 +125 When connected to the input, these modules will substantially improve the EMS performance of the converter. When used on the output, they will substantially reduce the converter output noise and ripple. Contact the factory for more information Typical Connection T: (781) 344-8226 F: (781) 344-8481 E: [email protected] W: www.micropowerdirect.com www.micropowerdirect.com www.micropowerdirect.com Mechanical Dimensions Pin Connections Pin 1 2 3 4 Function -VIN +VIN +VOUT -VOUT Mechanical Dimensions: With Chassis Mount Option (A2) The MDCFM-01A is available mounted on an adapter plate for mounting to a chassis or on a DIN rail. Mechanical dimensions for these adapters are shown at right. The photo below shows a product mounted on a similar adapter. Please contact the factory for more information. For the chassis mount option, add suffix “A2” to the model number (i.e. MDCFM-01A-A2) For the DIN rail mount option, add suffix “A4” to the model number (i.e. MDCFM-01A-A4) Pin Connections Mechanical Dimensions: With DIN Rail Option (A4) Pin Function 1 -VIN 2 No Connection 3 +VIN 4 +VOUT 5 -VOUT Connection is the same for A2 & A4 MicroPower Direct We Power Your Success - For Less! 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • Notes: • All dimensions are typical in inches (mm) • Tolerance x.xx = ±0.02 (±0.50) • Wire range for A2 & A4 connection is 24 - 12 AWG FAX: (781) 344-8481 • E-Mail: [email protected]