MACFM-02B Wide Input, AC Encapsulated EMC Filter Module Key Features: • 85 to 305 VAC Input • Compact Case • 30 dB Attenuation • -40°C to +85°C Operation • Chassis Mount Option • DIN Rail Mount Option • Low Cost Electrical Specifications Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice. Input Parameter Input Voltage Range, See Note 1 Nominal Current, See Note 2 Conditions Min. 85 Typ. Max. 305 1.5 Units VAC A Min. Typ. 2,000 Max. Units VAC dB General Parameter Test Voltage Frequency Attenuation Conducted Emissions Conditions 60 Sec, 1 mA Leakage Current 30 EN 55022 Surge Parameter Operating Temperature Range Storage Temperature Range Cooling Humidity Physical Class B Criteria B; ±2 kV (1.2 µS/50 µS 2⍀) EN 61000-4-5 Criteria B; ±6 kV (1.2 µS/50 µS 12⍀) Conditions Min. Typ. Max. Units Ambient -40 +25 +85 °C -55 +125 °C Free Air Convection RH, Non-condensing 95 % Module Chassis (A2) Mount DIN (A4) Mount Case Size Case Material Module Chassis (A2) Mount DIN (A4) Mount Weight Notes: 1. The Max input voltage level of the power supply must be less than the maximum specified input of the MACFM-02B. 2. The Max input current of the power supply must be less than the maximum specified nominal current of the MACFM-02B. See Mechanical Drawing (Page 2) See Mechanical Drawing (Page 2) See Mechanical Drawing (Page 2) Non-Conductive Black Plastic (UL94-V0) 1.77 Oz (50g) 2.48 Oz (70g) 3.19 Oz (90g) Schematic MACFM-02B filter modules operate with many standard MPD AC/DC power supplies. MicroPower Direct 292 Page Street Suite D Stoughton, MA 02072 USA With these modules, most AC power supplies will meet the surge requirements of EN 61000-4-5 and the EMS requirements of EN 55022. Contact the factory for information on our full range of filter products. Typical Connection T: (781) 344-8226 F: (781) 344-8481 E: [email protected] W: www.micropowerdirect.com www.micropowerdirect.com www.micropowerdirect.com Mechanical Dimensions Pin Connections Pin 1 2 3 4 5 Function GND IN(N) IN(L) OUT(L) OUT(N) Mechanical Dimensions: With Chassis Mount Option (A2) The MACFM-02B is available mounted on an adapter plate for mounting to a chassis or on a DIN rail. Mechanical dimensions for these adapters are shown at right. The photo below shows a product mounted on a similar adapter. Please contact the factory for more information. For the chassis mount option, add suffix “A2” to the model number (i.e. MACFM-02B-A2) For the DIN rail mount option, add suffix “A4” to the model number (i.e. MACFM-02B-A4) Pin Connections Pin 1 2 3 4 5 Mechanical Dimensions: With DIN Rail Option (A4) Function GND IN(N) IN(L) OUT(L) OUT(N) Connection is the same for A2 & A4 MicroPower Direct We Power Your Success - For Less! 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • Notes: • All dimensions are typical in inches (mm) • Tolerance x.xx = ±0.02 (±0.50) • Wire range for A2 & A4 connection is 24 - 12 AWG FAX: (781) 344-8481 • E-Mail: [email protected]