MDCFM-40U Datasheet

MDCFM-40U
40V-160VDC Input,
Compact EMC
Filter Module
Key Features:
• 40 to 110 VDC Input
• Compact 1” x 2” Case
• Meets EN 50155
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
Parameter
Conditions
• Reverse Polarity Protection
• 1.2 MHour MTBF
No Load Current, See Note 2
• -40°C to +85°C Operation
General
• 98% Efficiency
Parameter
• Low Cost
Max.
Units
160
VDC
MDCFM-40U-10, MDCFM-40U-30
1.0
MDCFM-40U-50
3.0
Conditions
Efficiency
Typ.
40
• Chassis Mount Option
• DIN Rail Mount Option
Min.
Input Voltage Range, See Note 1
Min.
Typ.
MDCFM-40U-10
95
MDCFM-40U-30, MDCFM-40U-50
98
Max Output Voltage
mA
Max.
Units
%
165
Max Output Power
VDC
MDCFM-40U-10
10
MDCFM-40U-30
30
MDCFM-40U-50
50
W
EMI Characteristics (See Note 4)
Parameter
Standard
Radiated Emissions
Level
EN 55022
Conducted Emissions
Class B (150 kHz - 30 MHz)
EN 55022
Class B (30 MHz - 1 GHz)
ESD
EN 61000-4-2
Criteria B; Air ±8 kV, Contact ±6 kV
RS
EN 61000-4-3
Criteria A; 10V/m
EFT
EN 61000-4-4
Surge
EN 61000-4-5
CS
EN 61000-4-6
Vibration
EN 61373
Criteria B; ±4 kV (5 kHz - 100 kHz)
Criteria B; ±2 kV (1.2 µS/50 µS 2⍀)
Criteria B; ±4 kV (1.2 µS/50 µS 12⍀)
Criteria B; 10 Vrms
Sinusoidal 5~150 Hz; 7.5 mm
Amplitude; 10g Acceleration
Environmental
Parameter
Conditions
Operating Temperature Range
Ambient
Storage Temperature Range
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T: (781) 344-8226
F: (781) 344-8481
E: [email protected]
W: www.micropowerdirect.com
Typ.
Max.
Units
-40
+25
+85
°C
+125
°C
95
%
-55
Cooling
Humidity
Min.
Free Air Convection
RH, Non-condensing
Physical
Case Size
Module
See Mechanical Drawing (Page 2)
Chassis (A2) Mount
See Mechanical Drawing (Page 2)
DIN (A4) Mount
Case Material
Weight
See Mechanical Drawing (Page 2)
Non-Conductive Black Plastic (UL94-V0)
Module
1.77 Oz (50g)
Chassis (A2) Mount
2.48 Oz (70g)
DIN (A4) Mount
3.19 Oz (90g)
www.micropowerdirect.com
www.micropowerdirect.com
Model Selection Guide
Input Voltage Range (VDC)
Model
Number
Withstand
Voltage
Max.
Output
Power
Efficiency
(%)
Nominal
Range
MDCFM-40U-10
110
40 - 160
500
10
95%
MDCFM-40U-30
110
40 - 160
500
30
98%
MDCFM-40U-50
110
40 - 160
1,500
50
98%
(VAC)
Notes:
1. The Max input voltage level of the DC/DC converter must be less than the maximum specified input of the MDCFM-40U.
2. The maximum power of the DC/DC converter must be less than the maximum output
power of the MDCFM-40.
3. The -VOUT pin should not be connected to the “ground” input.
(W)
Efficiency vs Input Voltage (Full Load)
Typical Connection
Efficiency vs Output Power (VIN= 110 VDC)
The diagram at right shows a typical connection for a MDCFM-40U series filter
module. Prawing at right i The external capacitors shown in the typical connection diagram below are required to meet specified operation. Recommended
component values are given in the table below.
Component
C1
CY1, CY2
Value
400 µF/200V
1nF/2 kV
The “GND” input should not be connected to the -VIN pin or the -VOUT pin of the
filter. Also, the Y capacitors should be connected as shown, not from the filter
module input to the DC/DC module output.
292 Page Street Ste D Stoughton, MA 02072
• TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: [email protected]
www.micropowerdirect.com
Mechanical Dimensions, MDCFM-40U-10
Pin Connections
Pin
1
2
3
4
5
Function
GND
-VIN
+VIN
+VOUT
-VOUT
Mechanical Dimensions: With Chassis Mount Option (A2)
The MDCFM-40U-10 is available mounted on an adapter plate for mounting to a
chassis or on a DIN rail. Mechanical dimensions for these adapters is shown at right.
The photo below shows a product mounted on a similar adapter. Please contact the
factory for more information.
For the chassis mount option, add suffix “A2” to the
model number (i.e. MDCFM-40U-10-A2)
For the DIN rail mount option, add suffix “A4” to the
model number (i.e. MDCFM-40U-10-A4)
Pin Connections
Pin
1
2
3
4
5
Mechanical Dimensions: With DIN Rail Option (A4)
Function
GND
-VIN
+VIN
+VOUT
-VOUT
Connection is the
same for A2 & A4
Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = ±0.02 (±0.50)
• Wire range for A2 & A4 connection is 24 - 12 AWG
MicroPower Direct
•
292 Page Street Ste D Stoughton, MA 02072
• TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: [email protected]
Mechanical Dimensions, MDCFM-40U-30, MDCFM-40U-50
www.micropowerdirect.com
Pin Connections
Pin
1
2
3
4
5
Function
GND
-VIN
+VIN
+VOUT
-VOUT
Mechanical Dimensions: With Chassis Mount Option (A2)
The MDCFM-40U-30/50 are available mounted on an adapter plate for mounting
to a chassis or on a DIN rail. Mechanical dimensions for these adapters are shown at
right. The photo below shows a product mounted on a similar adapter. Please contact
the factory for more information.
For the chassis mount option, add suffix “A2” to the
model number (i.e. MDCFM-40U-30-A2)
For the DIN rail mount option, add suffix “A4” to the
model number (i.e. MDCFM-40U-50-A4)
Pin Connections
Pin
1
2
3
4
5
Mechanical Dimensions: With DIN Rail Option (A4)
Function
GND
-VIN
+VIN
+VOUT
-VOUT
Connection is the
same for A2 & A4
Notes:
MicroPower Direct
• All dimensions are typical in inches (mm)
• Tolerance x.xx = ±0.02 (±0.50)
• Wire range for A2 & A4 connection is 24 - 12 AWG
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: [email protected]