MPM-40Mx Datasheet - Micropower Direct

MPM-40M Series
Medical Approved, 40W
Single & Dual Output
AC/DC Power Supplies
Key Features:
• 40W Output Power
• EN 60601-1 3RD Edition
• Universal 85-264 VAC Input
• EN 60950 Approved
• Reinforced Insulation
• Meets IEC Safety Class II
• Low Leakage Current
• Single and Dual Outputs
• Meets UL 508
Electrical Specifications
Specifications typical @ +25°C, 230 VAC input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
Parameter
Conditions
Input Voltage Range
Input Frequency
No Load Power Consumption
Output
Parameter
Output Voltage Accuracy
Line Regulation
Ripple & Noise (20 MHz), See Note 3
Hold-Up Time
Temperature Coefficient
Over Voltage Protection
Overshoot
Overload Protection
Over Temperature Protection
Short Circuit Protection, See Note 7
General
Parameter
Isolation Voltage (Reinforced)
Leakage Current
Isolation Resistance
Switching Frequency
Environmental
Parameter
Radiated Emissions
Conducted Emissions
ESD
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T: (781) 344-8226
F: (781) 344-8481
E: [email protected]
W: www.micropowerdirect.com
115 VAC
230 VAC
Inrush Current, See Note 2
Load Regulation, IO = Min to Max
Chassis Mount Models
& DIN Rail Mount
Option Available!
Min.
85
120
47
Conditions
Max.
264
370
440
30
60
Min.
VIN = Min to Max
Single Output
Dual Output
5.0 VDC Output
All Other Outputs
115 VAC, 60 Hz
230 VAC, 50 Hz
See Note 4
Typ.
±2.0
±0.5
±1.0
±2.0
1.5
1.0
25
80
±0.02
120
Conditions
Input to Output
Min.
4,000
500 VDC
1,000
Typ.
A Pk
W
Max.
Units
%
%
%
1.8
1.3
%VP-P of VO
5
%/°C
% of VO
%
% INOM
°C
mS
Max.
80
130
Standard
EN 55014, EN 55024
EN 55022
EN 61000-4-3
EN 61000-4-4
EN 61000-4-5
EN 61000-4-6
EN 61000-4-8
EN 61000-4-11
EN 61000-4-11
Criterea
A
A
A
A
A
A
A
A
B
Units
VAC
VDC
Hz
0.3
See Note 5 105
See Note 6
90
Continuous (Autorecovery)
EN 61000-4-2
RS
EFT
Surge
CS
PFM
Voltage Dips
Interruptions
Environmental
Parameter
Operating Temperature Range
Storage Temperature Range
Cooling, See Note 8
Humidity
Physical
Case Size
Case Material
Reliability Specifications
Parameter
MTBF
Safety Standards
Safety Class
Typ.
Units
VAC rms
µA
M⍀
kHz
Level
Class B
Class B
±8 kV Air
±4 kV Contact
10 V/m
±2 kV
±1 kV
10 Vrms
30 A/M
30% 10 mS
95% 5,000 mS
Conditions
Min.
Typ.
Max.
-40
+25
+80
-40
+95
Free Air Convection (See Derating Curve)
RH, Non-condensing
95
Ambient
Units
°C
°C
%
See Mechanical Diagrams (Pages 3 & 4)
Non-Conductive Plastic Resin (UL94-V0)
Conditions
Min.
Typ.
MIL HDBK 217F, 25°C, Gnd Benign
200
UL 60950, EN 60950
IEC 60536 Class II
www.micropowerdirect.com
Max.
Units
kHours
www.micropowerdirect.com
Model Selection Guide
Model
Number
Output
Input Current
(mA Typ)
Voltage
(VDC)
Current (A)
Min.
(µF, Max)
Efficiency
(%, Typ)
115 VAC
230 VAC
MPM-40MS-05xx
716
429
5.0
8.00
0.00
8,000
81
MPM-40MS-12xx
689
414
12.0
3.33
0.00
3,900
84
MPM-40MS-15xx
680
408
15.0
2.66
0.00
3,900
85
MPM-40MS-24xx
687
413
24.0
1.66
0.00
680
84
MPM-40MD-12xx
687
413
±12.0
±1.66
0.00
1,500
84
MPM-40MD-15xx
680
408
±15.0
±1.33
0.00
1,000
85
Notes:
1. The specified maximum capacitive load is for each output.
2. Inrush current is given for a cold start at 25°C.
3. Ripple and noise is measured with a 0.1 µF/50V MLCC and a
1 µF/50V aluminum electrolytic connected between the +VOUT
and -VOUT pins for single output models or from each output to
common for dual output models.
4. Over voltage protection is provided by a zener diode clamp.
5. Output overload protection is provided by a “hiccup mode” circuit
with auto-recovery. A long-term overload could damage the unit.
6. The unit will shutdown at 90°C. It will recover automatically at
about 67 °C.
7. Output short circuit protection is provided by a “hiccup mode”
circuit. The unit recovers automatically when the fault condition
is removed.
8. Free air (natural) convection is about 20 LFM, it is not equal to
“still” air.
9. Operation at no-load will not damage these units. However, they
may not meet all specifications.
10. It is recommended that an external slow blow fuse also be used
on the input for protection.
Max.
Capacitive
Load
Other outputs may be available
Contact the factory for details at:
[email protected]
Model Number
Derating Curve
Chassis Mount & DIN Rail
All models of the MPM-40Mx series
are available in an encapsulated
package that can be mounted to a
chassis or cabinet and connected with
flying leads. To order the unit in this
package, add a “CM” to the end of the
product number.
This package can also be adapted for
use with a standard DIN rail by installing a simple adapter kit. As illustrated
at right, this DIN rail kit consists of
a base plate, a DIN rail bracket and
the necessary hardware. For the
MPM-40Mx series the DIN rail kit is:
AC-DIN-02.
292 Page Street Ste D Stoughton, MA 02072
• TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: [email protected]
Mechanical Dimensions
www.micropowerdirect.com
Pin Connections
Pin
Single
Dual
1
AC Neutral
AC Neutral
2
AC Line
AC Line
3
+VOUT
+VOUT
5
-VOUT
Common
7
NC
-VOUT
NC = No Connection
Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = ±0.02 (±0.5)
Mechanical Dimensions, Chassis Mount
For the “Chassis Mount” package, add suffix “CM”
to the model number (i.e. MPM-40MS-12CM)
Pin Connections
Pin
Single
Dual
1
AC Neutral
AC Neutral
2
AC Line
AC Line
3
+VOUT
+VOUT
4
NC
NC
5
-VOUT
Common
6
NC
NC
7
NC
-VOUT
NC = No Connection
Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = ±0.02 (±0.5)
MicroPower Direct
•
292 Page Street Ste D Stoughton, MA 02072
• TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: [email protected]
www.micropowerdirect.com
DIN Rail Mounting
All chassis mount MPM-40Mx models are easily
adapted for use with a standard 35 mm DIN rail by
installing a simple adapter kit.
The DIN rail kit consists of a base plate, a DIN rail
bracket and the necessary hardware. Mechanical dimensions for an MPM-40Mx assembly with the DIN rail
option are shown below.
For the MPM-40Mx series the DIN rail kit is: AC-DIN-02.
Mechanical Dimensions, DIN Rail Mount
Pin Connections
Pin
Single
Dual
1
AC Neutral
AC Neutral
2
AC Line
AC Line
3
+VOUT
+VOUT
4
NC
NC
5
-VOUT
Common
6
NC
NC
7
NC
-VOUT
NC = No Connection
Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = ±0.02 (±0.5)
MicroPower Direct
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: [email protected]