MPM-40M Series Medical Approved, 40W Single & Dual Output AC/DC Power Supplies Key Features: • 40W Output Power • EN 60601-1 3RD Edition • Universal 85-264 VAC Input • EN 60950 Approved • Reinforced Insulation • Meets IEC Safety Class II • Low Leakage Current • Single and Dual Outputs • Meets UL 508 Electrical Specifications Specifications typical @ +25°C, 230 VAC input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice. Input Parameter Conditions Input Voltage Range Input Frequency No Load Power Consumption Output Parameter Output Voltage Accuracy Line Regulation Ripple & Noise (20 MHz), See Note 3 Hold-Up Time Temperature Coefficient Over Voltage Protection Overshoot Overload Protection Over Temperature Protection Short Circuit Protection, See Note 7 General Parameter Isolation Voltage (Reinforced) Leakage Current Isolation Resistance Switching Frequency Environmental Parameter Radiated Emissions Conducted Emissions ESD MicroPower Direct 292 Page Street Suite D Stoughton, MA 02072 USA T: (781) 344-8226 F: (781) 344-8481 E: [email protected] W: www.micropowerdirect.com 115 VAC 230 VAC Inrush Current, See Note 2 Load Regulation, IO = Min to Max Chassis Mount Models & DIN Rail Mount Option Available! Min. 85 120 47 Conditions Max. 264 370 440 30 60 Min. VIN = Min to Max Single Output Dual Output 5.0 VDC Output All Other Outputs 115 VAC, 60 Hz 230 VAC, 50 Hz See Note 4 Typ. ±2.0 ±0.5 ±1.0 ±2.0 1.5 1.0 25 80 ±0.02 120 Conditions Input to Output Min. 4,000 500 VDC 1,000 Typ. A Pk W Max. Units % % % 1.8 1.3 %VP-P of VO 5 %/°C % of VO % % INOM °C mS Max. 80 130 Standard EN 55014, EN 55024 EN 55022 EN 61000-4-3 EN 61000-4-4 EN 61000-4-5 EN 61000-4-6 EN 61000-4-8 EN 61000-4-11 EN 61000-4-11 Criterea A A A A A A A A B Units VAC VDC Hz 0.3 See Note 5 105 See Note 6 90 Continuous (Autorecovery) EN 61000-4-2 RS EFT Surge CS PFM Voltage Dips Interruptions Environmental Parameter Operating Temperature Range Storage Temperature Range Cooling, See Note 8 Humidity Physical Case Size Case Material Reliability Specifications Parameter MTBF Safety Standards Safety Class Typ. Units VAC rms µA M⍀ kHz Level Class B Class B ±8 kV Air ±4 kV Contact 10 V/m ±2 kV ±1 kV 10 Vrms 30 A/M 30% 10 mS 95% 5,000 mS Conditions Min. Typ. Max. -40 +25 +80 -40 +95 Free Air Convection (See Derating Curve) RH, Non-condensing 95 Ambient Units °C °C % See Mechanical Diagrams (Pages 3 & 4) Non-Conductive Plastic Resin (UL94-V0) Conditions Min. Typ. MIL HDBK 217F, 25°C, Gnd Benign 200 UL 60950, EN 60950 IEC 60536 Class II www.micropowerdirect.com Max. Units kHours www.micropowerdirect.com Model Selection Guide Model Number Output Input Current (mA Typ) Voltage (VDC) Current (A) Min. (µF, Max) Efficiency (%, Typ) 115 VAC 230 VAC MPM-40MS-05xx 716 429 5.0 8.00 0.00 8,000 81 MPM-40MS-12xx 689 414 12.0 3.33 0.00 3,900 84 MPM-40MS-15xx 680 408 15.0 2.66 0.00 3,900 85 MPM-40MS-24xx 687 413 24.0 1.66 0.00 680 84 MPM-40MD-12xx 687 413 ±12.0 ±1.66 0.00 1,500 84 MPM-40MD-15xx 680 408 ±15.0 ±1.33 0.00 1,000 85 Notes: 1. The specified maximum capacitive load is for each output. 2. Inrush current is given for a cold start at 25°C. 3. Ripple and noise is measured with a 0.1 µF/50V MLCC and a 1 µF/50V aluminum electrolytic connected between the +VOUT and -VOUT pins for single output models or from each output to common for dual output models. 4. Over voltage protection is provided by a zener diode clamp. 5. Output overload protection is provided by a “hiccup mode” circuit with auto-recovery. A long-term overload could damage the unit. 6. The unit will shutdown at 90°C. It will recover automatically at about 67 °C. 7. Output short circuit protection is provided by a “hiccup mode” circuit. The unit recovers automatically when the fault condition is removed. 8. Free air (natural) convection is about 20 LFM, it is not equal to “still” air. 9. Operation at no-load will not damage these units. However, they may not meet all specifications. 10. It is recommended that an external slow blow fuse also be used on the input for protection. Max. Capacitive Load Other outputs may be available Contact the factory for details at: [email protected] Model Number Derating Curve Chassis Mount & DIN Rail All models of the MPM-40Mx series are available in an encapsulated package that can be mounted to a chassis or cabinet and connected with flying leads. To order the unit in this package, add a “CM” to the end of the product number. This package can also be adapted for use with a standard DIN rail by installing a simple adapter kit. As illustrated at right, this DIN rail kit consists of a base plate, a DIN rail bracket and the necessary hardware. For the MPM-40Mx series the DIN rail kit is: AC-DIN-02. 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: [email protected] Mechanical Dimensions www.micropowerdirect.com Pin Connections Pin Single Dual 1 AC Neutral AC Neutral 2 AC Line AC Line 3 +VOUT +VOUT 5 -VOUT Common 7 NC -VOUT NC = No Connection Notes: • All dimensions are typical in inches (mm) • Tolerance x.xx = ±0.02 (±0.5) Mechanical Dimensions, Chassis Mount For the “Chassis Mount” package, add suffix “CM” to the model number (i.e. MPM-40MS-12CM) Pin Connections Pin Single Dual 1 AC Neutral AC Neutral 2 AC Line AC Line 3 +VOUT +VOUT 4 NC NC 5 -VOUT Common 6 NC NC 7 NC -VOUT NC = No Connection Notes: • All dimensions are typical in inches (mm) • Tolerance x.xx = ±0.02 (±0.5) MicroPower Direct • 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: [email protected] www.micropowerdirect.com DIN Rail Mounting All chassis mount MPM-40Mx models are easily adapted for use with a standard 35 mm DIN rail by installing a simple adapter kit. The DIN rail kit consists of a base plate, a DIN rail bracket and the necessary hardware. Mechanical dimensions for an MPM-40Mx assembly with the DIN rail option are shown below. For the MPM-40Mx series the DIN rail kit is: AC-DIN-02. Mechanical Dimensions, DIN Rail Mount Pin Connections Pin Single Dual 1 AC Neutral AC Neutral 2 AC Line AC Line 3 +VOUT +VOUT 4 NC NC 5 -VOUT Common 6 NC NC 7 NC -VOUT NC = No Connection Notes: • All dimensions are typical in inches (mm) • Tolerance x.xx = ±0.02 (±0.5) MicroPower Direct We Power Your Success - For Less! 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: [email protected]