MPU-300F Datasheet - Micropower Direct

MPU-300F Series
Single Output 300W
Power Factor Corrected
AC/DC Power Supplies
Key Features:
Electrical Specifications
• Small 300W Supply
• PFC to EN 61000-3-2 “D”
• EN 60950 Approved (UL)
• CE Certified
• FCC Class B Emissions
• Universal AC Input
• Internal Fan
• Small 5” x 3.2” x 2” Size
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
Parameter
Input Voltage Range
Input Frequency
Input Current, Full Load
Conditions
Universal
Inrush Current, Cold Start
Leakage Current, See Note 1
Power Factor Correction
Input Protection
Min.
90
47
Typ.
90 VAC
5
110 VAC
220 VAC
240 VAC
3.5
Meets EN 61000-3-2 Class D
F5A/350V Fuse
Max.
264
63
35
70
Units
VAC
Hz
A
A
mA
Output
Parameter
Output Regulation, See Note 2
Hold Time
Ripple & Noise (20 MHz) (See Note 3)
Overload Protection
Over Voltage Protection
Over Temperature Protection
Temperature Coefficient
Transient Recovery Time, See Note 4
Transient Response Deviation
Overshoot/Undershoot
Turn On Delay
Output Short Circuit
Conditions
Min.
Typ.
±1.0
Max.
120 VAC, 80% Load
16
See Model Selection Guide
Foldback Circuit, Autorecovery
110
140
>130% of Rated Output Voltage. Recycle AC Input.
Autorecovery
+110
±0.04
2.5
50% Load Change
5
At Turn On/Off
±5.0
120 VAC
1
Continuous With Autorecovery
Units
%
mSec
%
ºC
%/ºC
mS
%
%
S
General
Parameter
Isolation Voltage, See Note 5
Switching Frequency
Interface Signals
Power Supply On
Min.
3,000
1,500
1,500
Typ.
Max.
Units
VAC
24
kHz
Green LED on the PCB
An open collector output rated for 28V/5 mA sink current maximum.
Goes high if a fan failure is detected
Goes TTL high 100 to 500 mS after regulation. Goes low at least 1 mS
before the loss of regulation. Will sink 100 mA.
A TTL low signal inhibits the output. Hiccup mode.
Fan Fail
Power Good Signal
Remote On/Off
MicroPower Direct
Environmental
292 Page Street
Suite D
Stoughton, MA 02072
USA
Parameter
Operating Temperature Range
Output Derating
Storage Temperature Range
Cooling
Operating Humidity
T: (781) 344-8226
F: (781) 344-8481
E: [email protected]
W: www.micropowerdirect.com
Conditions
Input - Output
Input - FG (Frame Ground)
Primary - Core
Fixed
Conditions
Min.
Typ.
Max.
Units
0
+25
+50
ºC
2.5%/ ºC from +50 ºC to + 70 ºC
-20
+85
ºC
See Model Selection Guide
RH, Non-condensing
90
%
Ambient
Reliability Specifications
Parameter
MTBF
Safety Standards
EMI Compliance
EMS Immunity Compliance
Vibration
Conditions
Min.
Typ.
Max.
Units
MIL HDBK 217F, 30ºC, Gnd Benign
100
kHours
UL 1950, EN 60950
Compliance to EN 55022 (CISPR22) Class B; EN 61000-3-2,3
EN 6100-4-2,3,4,5,6,11; EN 55024; CE Marked (LVD)
Sinusoidal 5~50 Hz, Acceleration ±7.35 m/s2 on X, Y & Z Axis
www.micropowerdirect.com
www.micropowerdirect.com
Model Selection Guide
Model
Number
Output Voltage (VDC)
PreSet
Range
Output Current
(Max. A)
Ripple &
Noise
(% p-p)
Efficiency
(%)
MPU-300S-12yF
12 VDC
12.0 - 13.8
25.00
±1%
80%
MPU-300S-15yF
15 VDC
14.0 - 16.0
20.00
±1%
80%
MPU-300S-24yF
24 VDC
23.0 - 28.0
12.50
±1%
80%
MPU-300S-48yF
48 VDC
44.0 - 52.0
6.25
±1%
80%
Models with other output voltage levels
are available (i.e. 5 VDC, 30 VDC, etc)
Contact the factory for details at:
[email protected]
Notes:
1. Output regulation includes line & load.
2. Ripple & noise is measured from 10 Hz to 20 MHz. Connection to the unit is made with 0.1 µF ceramic & 22 µF electrolytic capacitors connected in parallel.
3. Transient recovery is measured to within a 1% error band for a load step change of 50% to 100%.
4. Isolation specifications are production HI-Pot tested for 3 seconds.
5. The full output range (see table) is covered in the safety agency certification. Standard models are factory set to the “Preset” voltage. This may be set to other levels within the range without affecting
the agency certification. For more information, contact the factory.
6. Output power is given for the factory preset voltage. The maximum continuous output power level is 300W. All models provide a peak power level of 600W for a maximum duration of 500 µS. For more
information, contact the factory.
7. Each unit includes an input fuse (350V/5A). Since this fuse is not field replaceable, it is recommended that an external fuse of the same size be used on the input of the power supply for protection.
Model Number
Mechanical Dimensions
Connections
Input Connector (CN1):
• Terminal Block:
Howder HD-601-3P
3 pins, 6.35 mm Centers
• Molex Mating Part No:
Molex 035977-0500 or equivalent
(two pins removed)
Pin
Function
1
2
3
AC-Line
AC-Neutral
Field Ground
Output Connector (CN2):
• Terminal Block (Must be used on 12 VOUT):
Dinkle P-830N
M5 Screws
• Molex Mating Part No:
Molex 035977-0600 or equivalent
Pin
Molex
Pin
Dinkle
1
2
3
4
5
6
-VOUT
-VOUT
-VOUT
+VOUT
+VOUT
+VOUT
1
2
-VOUT
+VOUT
Logic Signal Connector (CN3):
• Mating Part No:
JST XHP-4 or equivalent
(CHYAO SHIUNN JS-21001-4)
• Mating Pins: JST SXH-002T-PO.6
For AWG 30 to 26
MicroPower Direct
Pin
Function
1
2
3
4
Remote On/Off
Fan Fail
Common
Power Good
Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = ±0.02 (±0.50)
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: [email protected]