MPU-250 Datasheet - Micropower Direct

MPU-250 Series
Single Output 250W
Power Factor Corrected
AC/DC Power Supplies
Electrical Specifications
Key Features:
• Small 250W Supply
• PFC to EN 61000-3-2 “A”
• EN 60950 Approved (UL)
• CE Certified
• FCC Class B Emissions
• 90 to 264 VAC Input
• Small 5” x 3.2” x 1.5” Size
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
Parameter
Conditions
Input Voltage Range
Autoranging
Input Frequency
Input Current, Full Load
Inrush Current, Cold Start
Leakage Current
Power Factor Correction
Input Protection
Min.
90
180
47
Typ.
110 VAC
6
220 VAC
3
110 VAC
220 VAC
264 VAC
Meets EN 61000-3-2 Class A
T8A/250V Fuse
Max.
132
264
63
Units
VAC
Hz
A
35
70
1.0
A
mA
Output
Parameter
Output Voltage Adjustment
Output Regulation
Hold Time
Ripple & Noise (20 MHz) See Note 2
Overload Protection
Over Voltage Protection
Over Temperature Protection
Temperature Coefficient
Transient Recovery Time, See Note 4
Transient Response Deviation
Overshoot/Undershoot
Turn On Delay
Output Short Circuit
Conditions
Min.
Typ.
Max.
By Trim Pot
±5.0
See Note 1
±1.0
110 VAC, 80% Load
20
See Model Selection Guide
Autorecovery
110
140
>130% of Rated Output Voltage. Recycle AC Input.
Autorecovery
+110
±0.04
2.5
50% Load Change
5
At Turn On/Off
±5.0
230 VAC
1
Continuous With Autorecovery
Units
%
%
mSec
%
ºC
%/ºC
mS
%
%
S
General
Parameter
Isolation Voltage, See Note 5
Switching Frequency
Conditions
Input - Output
Input - FG (Frame Ground)
Primary - Core
Fixed
Min.
3,000
1,500
1,500
Typ.
Max.
Units
VAC
25
kHz
Interface Signals
Power Supply On
Green LED on the PCB
Goes TTL high 100 to 500 mS after regulation. Goes low at least 1 mS
before the loss of regulation.
A TTL low signal inhibits the output. Hiccup mode.
Power Good Signal
Remote On/Off
MicroPower Direct
Environmental
292 Page Street
Suite D
Stoughton, MA 02072
USA
Parameter
Operating Temperature Range
Output Derating
Storage Temperature Range
Cooling
Operating Humidity
T: (781) 344-8226
F: (781) 344-8481
E: [email protected]
W: www.micropowerdirect.com
Conditions
Min.
Typ.
Max.
Units
0
+25
+70
ºC
2.5%/ ºC from +50 ºC to + 70 ºC
-20
+85
ºC
See Model Selection Guide
RH, Non-condensing
90
%
Ambient
Reliability Specifications
Parameter
MTBF
Safety Standards
EMI Compliance
EMS Immunity Compliance
Vibration
Conditions
Min.
Typ.
Max.
Units
MIL HDBK 217F, 30ºC, Gnd Benign
100
kHours
UL 60950, EN 60950
Compliance to EN 55022 (CISPR22) Class B; EN 61000-3-2,3
EN 61000-4-2,3,4,5,6,11; EN 55024; CE Marked (LVD)
Sinusoidal 5~50 Hz, Acceleration ±7.35 m/s2 on X, Y & Z Axis
www.micropowerdirect.com
www.micropowerdirect.com
Model Selection Guide
Model
Number
Output Voltage (VDC) Output Current (Max A) Ripple
& Noise Efficiency
(%)
PreSet
Range
Convection 16With
CFM (% p-p)
MPU-250S-12YZ
12 VDC 11.0 - 13.8
11.25
20.83
±1%
83%
MPU-250S-15YZ
15 VDC 14.0 - 15.5
9.00
16.66
±1%
83%
MPU-250S-24YZ
24 VDC 21.0 - 26.0
5.62
10.41
±1%
83%
MPU-250S-36YZ
36 VDC 35.0 - 42.0
3.75
5.21
±1%
83%
Model Number
Notes:
1. Output regulation includes line & load.
2. Ripple & noise is measured from 10 kHz to 20 MHz. Connection to the unit is made with
a 0.1 µF ceramic capacitor & a 22 µF electrolytic capacitor connected in parallel.
3. A 1% minimum load is required to maintain regulation & ripple specifications.
4. Transient recovery is measured to within a 1% error band for a load step of 50% to 100%.
5. Isolation specifications are production HI-Pot tested for 3 seconds.
6. The full output range (see table) is covered in the safety agency certification. Standard
models are factory set to the Preset voltage, but may be set to other levels within the range
without affecting the agency certification. For more information, contact the factory.
7. Output power is given for the factory preset voltage. The maximum continuous output
power level is 135W without providing 16 CFM airflow. All models provide a peak power
level of 600W for a maximum duration of 500 µS. For more information, contact the factory.
8. Each unit includes an input fuse (250V/8A). Since this fuse is not field replaceable, it is
recommended that an external fuse of the same size be used on the input of the power
supply for protection.
Models with other output voltage levels
are available (i.e. 5 VDC, 48 VDC, etc)
Contact the factory for details at:
[email protected]
Mechanical Dimensions
Connections
Input Connector (CN1):
• Terminal Block:
Howder HD-601-3P
3 pins, 6.35 mm Centers
• Molex Mating Part No:
Molex 09-91-0500 or equivalent
(two pins removed)
Pin
Function
1
2
3
AC-Line
AC-Neutral
Field Ground
Output Connector (CN2):
• Terminal Block:
Howder HD-601-4P
4 pins, 6.35 mm Centers
• Molex Mating Part No:
Molex 09-91-0600 or equivalent
Pin
Molex
1
2
3
4
5
6
+VOUT
+VOUT
+VOUT
-VOUT
-VOUT
-VOUT
Pin Howder
1
2
3
4
+VOUT
+VOUT
-VOUT
-VOUT
Logic Signal Connector (CN3):
• Mating Part No:
JST XHP-3 or equivalent
(CHYAO SHIUNN JS-2001-03)
• Mating Pins: JST SXH-002T-PO.6
For AWG 30 to 26
U-Chassis Cover (C Suffix)
Pin
Function
1
2
3
Power Good
Remote On/Off
Common
Fan Driver Connector (CN4):
• Mating Part No:
JST XHP-2 or equivalent
(CHYAO SHIUNN JS-2001-2)
MicroPower Direct
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
Pin
Function
1
2
Minus
Plus
Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = ±0.02 (±0.50)
FAX: (781) 344-8481
•
E-Mail: [email protected]