CURRENT SENSE TRANSFORMERS P4100E5 SERIES • Surface Mount Current Sense Transformers • Peak Current Sensing: 10A and 40% Duty Cycle • Operating Frequency: 50KHz to 1MHz • Operating Temperature: -40°C to +85°C • RoHS Compliant Product • Custom Design Available ELECTRICAL PARAMETERS @25°C Part Number P4100E5- Inductance (Ns) (mH Min) 20 Turns DCR (Ns) (Ω MAX) Current (±2% Max) DCR (8-7) (mΩ MAX) 0.08 1:20 6 0.55 10 30 0.18 1:30 6 0.87 10 40 0.32 1:40 6 1.14 10 50 0.50 1:50 6 1.50 10 60 0.72 1:60 6 1.75 10 (A) 70 0.98 1:70 6 4.75 10 100 2.00 1:100 6 5.50 10 125 3.00 1:125 6 6.50 10 NOTES: • Inductance tested at 15.75KHz, 0.1 Vrms • Hipot: 500Vrms Min DIMENSIONS Product performance is limited to specified parameters. Data is subject to change without prior notice. Tel: 310-325-1043 Fax: 310-325-1044 SCHEMATIC Dimensions Unless otherwise specified, all tolerances are: inch: .XX : ±0.015 .XXX : ±0.004 mm: X,X : ±0,38 X,XX : ±0,10 www.mpsind.com sales@mpsind.com