CCFL TRANSFORMER P9101 SERIES Industries • Output power up to 6 Watts • Designed for 40KHz - 100KHz LCD backlight applications • Add Schematic Suffix Letter after the Part No. ( Example: P9101-1A for Schematic A ) • Operating Temperature: -40°C to +85° • RoHS compliant product ELECTRICAL PARAMETERS @25°C Part Number • • DCR Max (Ω) Vpri Volt P9101- Pri OCL Nom (µH) Isec (7-10) Sec (7-10) Max DCR (mA) Max Pri: Fb (Ω) ±5% 1 44 0.22 23 1:67 1:0.19 5 285 0.10 2 44 0.16 20 1:67 1:0.17 11 176 0.10 3 44 0.22 32 1:50 1:0.14 7 165 0.10 4 44 0.16 26 1:50 1:0.17 11 132 0.10 5 31 0.13 18 1:86 1:0.21 11 176 0.10 6 40 0.18 17 1:93 1:0.25 11 176 0.10 7 22 0.13 16 1:100 1:0.25 11 176 0.10 8 20 0.13 13 1:100 1:0.17 11 176 0.10 9 20 0.13 13 1:125 1:0.25 11 291 0.10 Turns Ratio Pri: Sec ±5% Fb DCR Max (Ω) Inductance measured @ 100KHz, 0.1VRMS for both halves Primary ( Example: 1-3, 1-5) Hipot: 1500VRMS, 5 seconds ( Pri and Fb to Sec ); Schematic D is 500VRMS DIMENSIONS SCHEMATIC A SCHEMATIC B Product performance is limited to specified parameters. Data is subject to change without prior notice. 13200 Estrella Ave., Bldg. B Gardena, CA 90248 Tel: 310-325-1043 Fax: 310-325-1044 SCHEMATIC C Dimensions Unless otherwise specified, all tolerances are: inch: .XX : ±0.015 .XXX : ±0.004 mm: X,X : ±0,38 X,XX : ±0,10 www.mpsind.com [email protected]