40W AC-DC High Reliability Industrial Adaptor ■ Features Universal AC input / Full range 3 pole AC inlet IEC320-C14 No load power consumption<0.075W Energy efficiency Level VI Comply with EISA 2007/DoE,NRCan, GST40A series ■ Applications Consumer electronic devices Telecommunication devices Office facilities Industrial equipments AU/NZ MEPS,EU ErP and CoC Version 5 ClassⅠpower (with earth pin) Protections: Short circuit / Overload / Over voltage Fully enclosed plastic case Pass LPS Fanless design with -30~+70℃ working temperature LED indicator for power on 3 years warranty ■ Description GST40A is a highly reliable, 40W desktop style single-output green adaptor series. This product is a classⅠ power unit (with FG), equipped with a standard IEC320-C14 AC inlet and adopting the input range from 90VAC to 264VAC. The entire series supplies different models with output voltages ranging between 5VDC and 48VDC that can satisfy the demands for various types of consumer electronic devices. With the efficiency up to 92% and the extremely low no-load power consumption below 0.075W,GST40A is compliant with USA EISA 2007/DoE, Canada NRCan, Australia and New Zealand MEPS, EU ErP,and Code of Conduct (CoC) Version 5. The supreme feature allows the adaptor to save the energy when it is either under the operating mode or the standby mode. The entire series utilizes the 94V-0 flame retardant plastic case.GST40A is certified for the international safety regulations. ■ Model Encoding GST 40 A 05 - P1J DC plug type { P1J: Plug for standard model,2.1ψ x5.5ψ x11mm,c+,tuning fork type Optional plug type available by customer requested Output voltage IEC320-C14 AC inlet Output wattage Series name File Name:GST40A-SPEC 2015-06-12 GST40A 40W AC-DC High Reliability Industrial Adaptor series SPECIFICATION ORDER NO. GST40A05-P1J GST40A07-P1J GST40A09-P1J GST40A12-P1J GST40A15-P1J GST40A18-P1J GST40A24-P1J GST40A48-P1J SAFETY MODEL NO. DC VOLTAGE OUTPUT GST40A05 Note.2 5V GST40A18 GST40A24 GST40A48 15V 18V 24V 48V 4.45A 3.34A 2.67A 2.22A 1.67A 0.84A CURRENT RANGE 0 ~ 5A 0 ~ 5.34A 0 ~ 4.45A 0 ~ 3.34A 0 ~ 2.67A 0 ~ 2.22A 0 ~ 1.67A 0 ~ 0.84A RATED POWER (max.) 25W 40W 40W 40W 40W 40W 40W 40W RIPPLE & NOISE (max.) Note.3 150mVp-p 150mVp-p 150mVp-p 150mVp-p 150mVp-p 150mVp-p 180mVp-p 240mVp-p VOLTAGE TOLERANCE Note.4 ±5.0% ±5.0% ±5.0% ±3.0% ±3.0% ±3.0% ±2.5% ±2.5% Note.5 ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±5.0% ±5.0% ±5.0% ±3.0% ±3.0% ±3.0% ±2.5% ±2.5% 90% 91% 92% 25.2 ~ 32.4V 50.4 ~ 64.8V Note.6 1000ms, 50ms / 230VAC 1000ms, 50ms / 115VAC at full load HOLD UP TIME (Typ.) VOLTAGE RANGE 50ms / 230VAC 15ms / 115VAC at full load 90 ~ 264VAC 127 ~ 370VDC FREQUENCY RANGE 47 ~ 63Hz EFFICIENCY (Typ.) 84.5% AC CURRENT (Typ.) INRUSH CURRENT (max.) 1A / 115VAC 87.5% 88.5% 89.5% 90% 0.5A / 230VAC 65A / 230VAC LEAKAGE CURRENT(max.) 0.75mA / 240VAC OVERLOAD 105 ~ 150% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed 5.25 ~ 6.75V 7.88 ~ 10.13V 9.45 ~ 12.15V 12.6 ~ 16.2V 15.75 ~ 20.25V 18.9 ~ 24.3V Protection type : Shut down o/p voltage, re-power on to recover PROTECTION OVER VOLTAGE WORKING TEMP. -30 ~ +70℃ (Refer to "Derating Curve") WORKING HUMIDITY 20% ~ 90% RH non-condensing -40 ~ +85℃, 10 ~ 95% RH ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS SAFETY & WITHSTAND VOLTAGE ISOLATION RESISTANCE EMC (Note. 7) EMC EMISSION EMC IMMUNITY NOTE GST40A15 12V 5.34A SETUP, RISE TIME CONNECTOR GST40A12 9V 5A LOAD REGULATION OTHERS GST40A09 7.5V RATED CURRENT LINE REGULATION INPUT GST40A07 MTBF DIMENSION ±0.03% / ℃ (0~50℃) 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes UL60950-1,CSA C22.2, TUV EN60950-1, BSMI CNS14336, CCC GB4943, PSE J60950-1 approved I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH Compliance to EN55022 class B, EN61000-3-2,3, FCC PART 15 / CISPR22 class B, CNS13438 class B, GB9254, GB17625.1 Compliance to EN61000-4-2,3,4,5,6,8,11, light industry level, criteria A 736.4K hrs min. MIL-HDBK-217F(25℃) 125*50*31.5mm (L*W*H) 0.28Kg; 40pcs/12.02Kg/1.05CUFT PACKING PLUG See page 3 ; Other type available by customer requested CABLE See page 3 ; Other type available by customer requested 1. All parameters are specified at 230VAC input, rated load, 25℃ 70% RH ambient. 2. DC voltage: The output voltage set at point measure by plug terminal & 50% load. 3. Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor. 4. Tolerance: includes set up tolerance, line regulation, load regulation. 5. Line regulation is measured from low line to high line at rated load. 6. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time. 7. The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on http://www.meanwell.com) File Name:GST40A-SPEC 2015-06-12 GST40A 40W AC-DC High Reliability Industrial Adaptor Derating Curve series Static Characteristics 100 100 90 80 80 70 LOAD (%) LOAD (%) 60 40 20 -30 0 10 20 30 40 50 60 70 (HORIZONTAL) AMBIENT TEMPERATURE (℃) 60 50 40 90 95 100 110 120 140 160 180 200 220 240 264 INPUT VOLTAGE (VAC) 60Hz Mechanical Specification Case No. GS60A Unit:mm UL1185 16AWG 1000±50mm for 5 ~ 15V UL1185 18AWG 1800±50mm for 18 ~ 48V 125 POWER LED 70±10mm C"+" 11±0.5mm ID 2.1 x OD 5.5 Outside Inside -V not connected to AC FG Plug Assignment Standard plug: P1J P1J P/N OUTPUT CENTER + Installation Manual Please refer to : http://www.meanwell.com/webnet/search/InstallationSearch.html File Name:GST40A-SPEC 2015-06-12