GST40A series

40W AC-DC High Reliability Industrial Adaptor
■ Features
Universal AC input / Full range
3 pole AC inlet IEC320-C14
No load power consumption<0.075W
Energy efficiency Level VI
Comply with EISA 2007/DoE,NRCan,
GST40A
series
■ Applications
Consumer electronic devices
Telecommunication devices
Office facilities
Industrial equipments
AU/NZ MEPS,EU ErP and CoC Version 5
ClassⅠpower (with earth pin)
Protections: Short circuit / Overload / Over voltage
Fully enclosed plastic case
Pass LPS
Fanless design with -30~+70℃ working temperature
LED indicator for power on
3 years warranty
■ Description
GST40A is a highly reliable, 40W desktop style single-output green adaptor series. This product is a classⅠ
power unit (with FG), equipped with a standard IEC320-C14 AC inlet and adopting the input range from
90VAC to 264VAC. The entire series supplies different models with output voltages ranging between 5VDC
and 48VDC that can satisfy the demands for various types of consumer electronic devices.
With the efficiency up to 92% and the extremely low no-load power consumption below 0.075W,GST40A is
compliant with USA EISA 2007/DoE, Canada NRCan, Australia and New Zealand MEPS, EU ErP,and Code
of Conduct (CoC) Version 5. The supreme feature allows the adaptor to save the energy when it is either
under the operating mode or the standby mode. The entire series utilizes the 94V-0 flame retardant plastic
case.GST40A is certified for the international safety regulations.
■ Model Encoding
GST 40 A 05 - P1J
DC plug type
{
P1J: Plug for standard model,2.1ψ x5.5ψ x11mm,c+,tuning fork type
Optional plug type available by customer requested
Output voltage
IEC320-C14 AC inlet
Output wattage
Series name
File Name:GST40A-SPEC 2015-06-12
GST40A
40W AC-DC High Reliability Industrial Adaptor
series
SPECIFICATION
ORDER NO.
GST40A05-P1J GST40A07-P1J GST40A09-P1J GST40A12-P1J GST40A15-P1J GST40A18-P1J GST40A24-P1J GST40A48-P1J
SAFETY MODEL NO.
DC VOLTAGE
OUTPUT
GST40A05
Note.2 5V
GST40A18
GST40A24
GST40A48
15V
18V
24V
48V
4.45A
3.34A
2.67A
2.22A
1.67A
0.84A
CURRENT RANGE
0 ~ 5A
0 ~ 5.34A
0 ~ 4.45A
0 ~ 3.34A
0 ~ 2.67A
0 ~ 2.22A
0 ~ 1.67A
0 ~ 0.84A
RATED POWER (max.)
25W
40W
40W
40W
40W
40W
40W
40W
RIPPLE & NOISE (max.) Note.3 150mVp-p
150mVp-p
150mVp-p
150mVp-p
150mVp-p
150mVp-p
180mVp-p
240mVp-p
VOLTAGE TOLERANCE Note.4 ±5.0%
±5.0%
±5.0%
±3.0%
±3.0%
±3.0%
±2.5%
±2.5%
Note.5 ±1.0%
±1.0%
±1.0%
±1.0%
±1.0%
±1.0%
±1.0%
±1.0%
±5.0%
±5.0%
±5.0%
±3.0%
±3.0%
±3.0%
±2.5%
±2.5%
90%
91%
92%
25.2 ~ 32.4V
50.4 ~ 64.8V
Note.6 1000ms, 50ms / 230VAC
1000ms, 50ms / 115VAC at full load
HOLD UP TIME (Typ.)
VOLTAGE RANGE
50ms / 230VAC
15ms / 115VAC at full load
90 ~ 264VAC 127 ~ 370VDC
FREQUENCY RANGE
47 ~ 63Hz
EFFICIENCY (Typ.)
84.5%
AC CURRENT (Typ.)
INRUSH CURRENT (max.)
1A / 115VAC
87.5%
88.5%
89.5%
90%
0.5A / 230VAC
65A / 230VAC
LEAKAGE CURRENT(max.)
0.75mA / 240VAC
OVERLOAD
105 ~ 150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
5.25 ~ 6.75V
7.88 ~ 10.13V 9.45 ~ 12.15V 12.6 ~ 16.2V 15.75 ~ 20.25V 18.9 ~ 24.3V
Protection type : Shut down o/p voltage, re-power on to recover
PROTECTION
OVER VOLTAGE
WORKING TEMP.
-30 ~ +70℃ (Refer to "Derating Curve")
WORKING HUMIDITY
20% ~ 90% RH non-condensing
-40 ~ +85℃, 10 ~ 95% RH
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
SAFETY & WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMC
(Note. 7)
EMC EMISSION
EMC IMMUNITY
NOTE
GST40A15
12V
5.34A
SETUP, RISE TIME
CONNECTOR
GST40A12
9V
5A
LOAD REGULATION
OTHERS
GST40A09
7.5V
RATED CURRENT
LINE REGULATION
INPUT
GST40A07
MTBF
DIMENSION
±0.03% / ℃ (0~50℃)
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
UL60950-1,CSA C22.2, TUV EN60950-1, BSMI CNS14336, CCC GB4943, PSE J60950-1 approved
I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
Compliance to EN55022 class B, EN61000-3-2,3, FCC PART 15 / CISPR22 class B, CNS13438 class B, GB9254, GB17625.1
Compliance to EN61000-4-2,3,4,5,6,8,11, light industry level, criteria A
736.4K hrs min. MIL-HDBK-217F(25℃)
125*50*31.5mm (L*W*H)
0.28Kg; 40pcs/12.02Kg/1.05CUFT
PACKING
PLUG
See page 3 ; Other type available by customer requested
CABLE
See page 3 ; Other type available by customer requested
1. All parameters are specified at 230VAC input, rated load, 25℃ 70% RH ambient.
2. DC voltage: The output voltage set at point measure by plug terminal & 50% load.
3. Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor.
4. Tolerance: includes set up tolerance, line regulation, load regulation.
5. Line regulation is measured from low line to high line at rated load.
6. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.
7. The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the
EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”
(as available on http://www.meanwell.com)
File Name:GST40A-SPEC 2015-06-12
GST40A
40W AC-DC High Reliability Industrial Adaptor
Derating Curve
series
Static Characteristics
100
100
90
80
80
70
LOAD (%)
LOAD (%)
60
40
20
-30
0
10
20
30
40
50
60
70
(HORIZONTAL)
AMBIENT TEMPERATURE (℃)
60
50
40
90
95
100
110
120
140
160
180
200
220
240
264
INPUT VOLTAGE (VAC) 60Hz
Mechanical Specification
Case No. GS60A
Unit:mm
UL1185 16AWG 1000±50mm for 5 ~ 15V
UL1185 18AWG 1800±50mm for 18 ~ 48V
125
POWER LED
70±10mm
C"+"
11±0.5mm
ID 2.1 x OD 5.5
Outside
Inside
-V not connected to AC FG
Plug Assignment
Standard plug: P1J
P1J
P/N
OUTPUT
CENTER
+
Installation Manual
Please refer to : http://www.meanwell.com/webnet/search/InstallationSearch.html
File Name:GST40A-SPEC 2015-06-12