Specification

GS36U
36W AC-DC Industrial Adaptor
series
■ Features :
Universal AC input / Full range
No load power consumption<0.3W
Energy efficiency Level Ⅴ
Comply with EISA 2007 and NRCan
2 pole USA plug
ClassⅡ power (without earth pin)
Protections: Short circuit / Overload / Over voltage
Pass LPS
Fully enclosed plastic case
2 years warranty
SPECIFICATION
ORDER NO.
SAFETY MODEL NO.
DC VOLTAGE
OUTPUT
GS36U05-P1J
GS36U09-P1J
GS36U12-P1J
GS36U24-P1J
GS36U48-P1J
GS36U05
GS36U09
GS36U12
GS36U24
GS36U48
9V
12V
24V
48V
Note.2 5V
RATED CURRENT
4.5A
3.5A
3A
1.5A
0.75A
CURRENT RANGE
0 ~ 4.5A
0 ~ 3.5A
0 ~ 3A
0 ~ 1.5A
0 ~ 0.75A
RATED POWER (max.)
22.5W
36W
31.5W
36W
36W
RIPPLE & NOISE (max.) Note.3 90mVp-p
90mVp-p
100mVp-p
180mVp-p
240mVp-p
VOLTAGE TOLERANCE Note.4 ±5.0%
±5.0%
±3.0%
±2.0%
±2.0%
LINE REGULATION
Note.5 ±1.0%
±1.0%
±1.0%
±1.0%
±1.0%
LOAD REGULATION
Note.6 ±5.0%
±5.0%
±3.0%
±2.0%
±2.0%
85.5%
87.5%
SETUP, RISE, HOLD UP TIME 1000ms, 20ms, 50ms/230VAC
VOLTAGE RANGE
90 ~ 264VAC 135 ~ 370VDC
FREQUENCY RANGE
INPUT
76.5%
AC CURRENT
INRUSH CURRENT (max.)
0.7A / 100VAC
84.5%
35A / 115VAC
0.25mA / 240VAC
OVERLOAD
110 ~ 250% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
105 ~ 135% rated output voltage
Protection type : Clamp by zener diode
-20 ~ +50℃ (Refer to "Derating Curve")
20% ~ 90% RH non-condensing
-20 ~ +85℃, 10 ~ 95% RH
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
SAFETY & WITHSTAND VOLTAGE
EMC
ISOLATION RESISTANCE
(Note. 7)
EMC EMISSION
NOTE
81.5%
LEAKAGE CURRENT(max.)
OVER VOLTAGE
CONNECTOR
47 ~ 63Hz
EFFICIENCY (Typ.)
PROTECTION
OTHERS
1000ms, 20ms, 15ms/115VAC at full load
±0.03% / ℃ (0 ~ 40℃)
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
UL60950-1, CSA C22.2, BSMI CNS14336 approved
I/P-O/P:4242VDC
I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH
Compliance to FCC PART 15 / CISPR22 class B, CNS13438 class B
PACKING
PLUG
692.3Khrs min. MIL-HDBK-217F(25℃)
79*54*33mm (L*W*H)
226g ; 60pcs / 15.5kg / CARTON
See page 2 ; Other type available by customer requested
CABLE
See page 2 ; Other type available by customer requested
MTBF
DIMENSION
1.All parameters are specified at 115VAC input, rated load, 25℃ 70% RH ambient.
2.DC voltage: The output voltage set at point measure by plug terminal & 50% load.
3.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor.
4.Tolerance: includes set up tolerance, line regulation, load regulation.
5.Line regulation is measured from low line to high line at rated load.
6.Load regulation is measured from 20% to 100% rated load.
7.The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the
EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”
(as available on http://www.meanwell.com)
File Name:GS36U-SPEC 2015-05-20
GS36U
36W AC-DC Industrial Adaptor
Mechanical Specification
series
Unit:mm
17
UL1185 16AWG 1000±50mm
60±10mm
70±10mm
C"+"
11±0.5mm
ID 2.1 x OD 5.5
NAME PLATE
Plug Assignment
33
79
P1J
OUTPUT
+
54
P/N
CENTER
Derating Curve
Static Characteristics
100
for 12~48V
90
LOAD (%)
LOAD (%)
100
70
for 5~9V
80
70
60
50
40
-20
10
20
30
40
AMBIENT TEMPERATURE (℃)
50
90
95
100
110
120
140
160
180
200
220
240
264
INPUT VOLTAGE (VAC) 60Hz
File Name:GS36U-SPEC 2015-05-20