GS36U 36W AC-DC Industrial Adaptor series ■ Features : Universal AC input / Full range No load power consumption<0.3W Energy efficiency Level Ⅴ Comply with EISA 2007 and NRCan 2 pole USA plug ClassⅡ power (without earth pin) Protections: Short circuit / Overload / Over voltage Pass LPS Fully enclosed plastic case 2 years warranty SPECIFICATION ORDER NO. SAFETY MODEL NO. DC VOLTAGE OUTPUT GS36U05-P1J GS36U09-P1J GS36U12-P1J GS36U24-P1J GS36U48-P1J GS36U05 GS36U09 GS36U12 GS36U24 GS36U48 9V 12V 24V 48V Note.2 5V RATED CURRENT 4.5A 3.5A 3A 1.5A 0.75A CURRENT RANGE 0 ~ 4.5A 0 ~ 3.5A 0 ~ 3A 0 ~ 1.5A 0 ~ 0.75A RATED POWER (max.) 22.5W 36W 31.5W 36W 36W RIPPLE & NOISE (max.) Note.3 90mVp-p 90mVp-p 100mVp-p 180mVp-p 240mVp-p VOLTAGE TOLERANCE Note.4 ±5.0% ±5.0% ±3.0% ±2.0% ±2.0% LINE REGULATION Note.5 ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% LOAD REGULATION Note.6 ±5.0% ±5.0% ±3.0% ±2.0% ±2.0% 85.5% 87.5% SETUP, RISE, HOLD UP TIME 1000ms, 20ms, 50ms/230VAC VOLTAGE RANGE 90 ~ 264VAC 135 ~ 370VDC FREQUENCY RANGE INPUT 76.5% AC CURRENT INRUSH CURRENT (max.) 0.7A / 100VAC 84.5% 35A / 115VAC 0.25mA / 240VAC OVERLOAD 110 ~ 250% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed 105 ~ 135% rated output voltage Protection type : Clamp by zener diode -20 ~ +50℃ (Refer to "Derating Curve") 20% ~ 90% RH non-condensing -20 ~ +85℃, 10 ~ 95% RH WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS SAFETY & WITHSTAND VOLTAGE EMC ISOLATION RESISTANCE (Note. 7) EMC EMISSION NOTE 81.5% LEAKAGE CURRENT(max.) OVER VOLTAGE CONNECTOR 47 ~ 63Hz EFFICIENCY (Typ.) PROTECTION OTHERS 1000ms, 20ms, 15ms/115VAC at full load ±0.03% / ℃ (0 ~ 40℃) 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes UL60950-1, CSA C22.2, BSMI CNS14336 approved I/P-O/P:4242VDC I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH Compliance to FCC PART 15 / CISPR22 class B, CNS13438 class B PACKING PLUG 692.3Khrs min. MIL-HDBK-217F(25℃) 79*54*33mm (L*W*H) 226g ; 60pcs / 15.5kg / CARTON See page 2 ; Other type available by customer requested CABLE See page 2 ; Other type available by customer requested MTBF DIMENSION 1.All parameters are specified at 115VAC input, rated load, 25℃ 70% RH ambient. 2.DC voltage: The output voltage set at point measure by plug terminal & 50% load. 3.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor. 4.Tolerance: includes set up tolerance, line regulation, load regulation. 5.Line regulation is measured from low line to high line at rated load. 6.Load regulation is measured from 20% to 100% rated load. 7.The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies. (as available on http://www.meanwell.com) File Name:GS36U-SPEC 2015-05-20 GS36U 36W AC-DC Industrial Adaptor Mechanical Specification series Unit:mm 17 UL1185 16AWG 1000±50mm 60±10mm 70±10mm C"+" 11±0.5mm ID 2.1 x OD 5.5 NAME PLATE Plug Assignment 33 79 P1J OUTPUT + 54 P/N CENTER Derating Curve Static Characteristics 100 for 12~48V 90 LOAD (%) LOAD (%) 100 70 for 5~9V 80 70 60 50 40 -20 10 20 30 40 AMBIENT TEMPERATURE (℃) 50 90 95 100 110 120 140 160 180 200 220 240 264 INPUT VOLTAGE (VAC) 60Hz File Name:GS36U-SPEC 2015-05-20