GST90A series

90W AC-DC High Reliability Industrial Adaptor
■ Features
Universal AC input / Full range
3 pole AC inlet IEC320-C14
Built-in active PFC function
No load power consumption<0.15W
Energy efficiency Level VI
Comply with EISA 2007/DoE,NRCan,
GST90A
series
■ Applications
Consumer electronic devices
Telecommunication devices
Office facilities
Industrial equipments
AU/NZ MEPS,EU ErP and CoC Version 5
ClassⅠpower (with earth pin)
Protections: Short circuit / Overload / Over voltage
/ Over temperature
Fully enclosed plastic case
Fanless design with -30~+70℃ working temperature
LED indicator for power on
3 years warranty
■ Description
GST90A is a highly reliable, 90W desktop style single-output green adaptor series. This product is a classⅠ
power unit (with FG), equipped with a standard IEC320-C14 AC inlet and adopting the input range from
90VAC to 264VAC. The entire series supplies different models with output voltages ranging between 12VDC
and 48VDC that can satisfy the demands for various types of consumer electronic devices.
With the efficiency up to 91% and the extremely low no-load power consumption below 0.15W,GST90A is
compliant with USA EISA 2007/DoE, Canada NRCan, Australia and New Zealand MEPS, EU ErP,and Code of
Conduct (CoC) Version 5. The supreme feature allows the adaptor to save the energy when
it is either under the operating mode or the standby mode. The entire series utilizes the 94V-0 flame retardant
plastic case.GST90A is certified for the international safety regulations.
■ Model Encoding
GST 90 A 12 - P1M
DC plug type
{
P1M: Plug for standard model,2.5ψ x5.5ψ x11mm,c+,tuning fork type
Optional plug type available by customer requested
Output voltage
IEC320-C14 AC inlet
Output wattage
Series name
File Name:GST90A-SPEC 2015-06-12
90W AC-DC High Reliability Industrial Adaptor
GST90A
series
SPECIFICATION
ORDER NO.
SAFETY MODEL NO.
DC VOLTAGE
OUTPUT
NOTE
GST90A48-P1M
GST90A12
GST90A15
GST90A19
GST90A24
GST90A48
15V
19V
24V
48V
1.87A
6A
4.74A
3.75A
CURRENT RANGE
0 ~ 6.67A
0 ~ 6A
0 ~ 4.74A
0 ~ 3.75A
0 ~ 1.87A
RATED POWER (max.)
80W
90W
90W
90W
90W
240mVp-p
RIPPLE & NOISE (max.) Note.3 120mVp-p
150mVp-p
180mVp-p
200mVp-p
VOLTAGE TOLERANCE Note.4 ±5.0%
±5.0%
±4.0%
±3.0%
±2.5%
Note.5 ±1.0%
±1.0%
±1.0%
±1.0%
±1.0%
±5.0%
±5.0%
±4.0%
±3.0%
±2.5%
90%
91%
SETUP, RISE TIME
Note.6 1000ms, 50ms / 230VAC
HOLD UP TIME (Typ.)
VOLTAGE RANGE
Note.7 90 ~ 264VAC
20ms / 230VAC
1000ms, 50ms / 115VAC at full load
20ms / 115VAC at full load
127 ~ 370VDC
FREQUENCY RANGE
47 ~ 63Hz
POWER FACTOR (Typ.)
PF>0.91 / 230VAC
EFFICIENCY (Typ.)
89%
AC CURRENT (Typ.)
INRUSH CURRENT (max.)
1.3A / 115VAC
PF>0.95 / 115VAC at full load
89.5%
90%
0.6A / 230VAC
70A / 230VAC
LEAKAGE CURRENT(max.)
1mA / 240VAC
OVERLOAD
110 ~ 150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
105 ~ 135% rated output voltage
Protection type : Shut down o/p voltage, re-power on to recover
OVER VOLTAGE
OVER TEMPERATURE
Shut down o/p voltage, re-power on to recover
WORKING TEMP.
WORKING HUMIDITY
-30 ~ +70℃ (Refer to "Derating Curve")
20% ~ 90% RH non-condensing
SAFETY STANDARDS
WITHSTAND
VOLTAGE
SAFETY &
ISOLATION
RESISTANCE
EMC
(Note. 8)
EMC EMISSION
CONNECTOR
GST90A24-P1M
6.67A
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
OTHERS
GST90A19-P1M
Note.2 12V
LOAD REGULATION
PROTECTION
GST90A15-P1M
RATED CURRENT
LINE REGULATION
INPUT
GST90A12-P1M
-40 ~ +85℃, 10 ~ 95% RH
±0.03% / ℃ (0~40℃)
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
UL60950-1,CSA C22.2, TUV EN60950-1, BSMI CNS14336, CCC GB4943, PSE J60950-1 approved
I/P-O/P: 3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
Compliance to EN55022 class B, EN61000-3-2,3, FCC PART 15 / CISPR22 class B, CNS13438 class B, GB9254, GB17625.1
EMC IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11, light industry level, criteria A
MTBF
DIMENSION
PACKING
PLUG
348.7K hrs min. MIL-HDBK-217F(25℃)
145*60*32mm (L*W*H)
0.45Kg; 30pcs/14.05Kg/1CUFT
See page 3 ; Other type available by customer requested
CABLE
See page 3 ; Other type available by customer requested
1. All parameters are specified at 230VAC input, rated load, 25℃ 70% RH ambient.
2. DC voltage: The output voltage set at point measure by plug terminal & 50% load.
3. Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor.
4. Tolerance: includes set up tolerance, line regulation, load regulation.
5. Line regulation is measured from low line to high line at rated load.
6. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.
7. Derating may be needed under low input voltages. Pleas check the derating curve for more details.
8. The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the
EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”
(as available on http://www.meanwell.com)
File Name:GST90A-SPEC 2015-06-12
GST90A
90W AC-DC High Reliability Industrial Adaptor
Derating Curve
series
Static Characteristics
100
100
90
80
80
60
70
LOAD (%)
LOAD (%)
50
40
20
-30
0
10
20
30
40
50
60
70
(HORIZONTAL)
AMBIENT TEMPERATURE (℃)
50
40
90
95
100
110
120
140
160
180
200
220
240
264
INPUT VOLTAGE (VAC) 60Hz
Mechanical Specification
Case No. GS90A
Unit:mm
Ul1185 14AWG 1000±50mm for 12 ~ 15V
UL1185 16AWG 1200±50mm for 19 ~ 48V
145
32
60
60
70±10mm
C"+"
11±0.5mm
POWER LED
ID 2.5 x OD 5.5
Outside
Inside
-V not connected to AC FG
Plug Assignment
Standard plug: P1M
P1M
P/N
OUTPUT
CENTER
+
Installation Manual
Please refer to : http://www.meanwell.com/webnet/search/InstallationSearch.html
File Name:GST90A-SPEC 2015-06-12