GS40 series

GS40
40W AC-DC Industrial Adaptor
series
■ Features :
Universal AC input / Full range
No load power consumption<0.3W
Energy efficiency Level Ⅴ
Comply with EISA 2007, NRCan, AU/NZ MEPS and EU ErP
3 pole AC inlet IEC320-C14
Class I power (with earth pin)
Protections: Short circuit / Overload / Over voltage
Pass LPS
Fully enclosed plastic case
LED indicator for power on
2 years warranty
(except for 48V)
SPECIFICATION
ORDER NO.
GS40A05-P1J GS40A07-P1J GS40A09-P1J GS40A12-P1J GS40A15-P1J GS40A18-P1J GS40A24-P1J GS40A48-P1J
SAFETY MODEL NO.
DC VOLTAGE
OUTPUT
GS40A05
Note.2 5V
GS40A18
GS40A24
GS40A48
15V
18V
24V
48V
4.45A
3.34A
2.67A
2.22A
1.67A
0.84A
CURRENT RANGE
0 ~ 5A
0 ~ 5.34A
0 ~ 4.45A
0 ~ 3.34A
0 ~ 2.67A
0 ~ 2.22A
0 ~ 1.67A
0 ~ 0.84A
RATED POWER (max.)
25W
40W
40W
40W
40W
40W
40W
40W
RIPPLE & NOISE (max.) Note.3 100mVp-p
100mVp-p
100mVp-p
100mVp-p
100mVp-p
150mVp-p
180mVp-p
240mVp-p
VOLTAGE TOLERANCE Note.4 ±5.0%
±5.0%
±5.0%
±3.0%
±3.0%
±3.0%
±2.5%
±2.5%
Note.5 ±1.0%
±1.0%
±1.0%
±1.0%
±1.0%
±1.0%
±1.0%
±1.0%
±5.0%
±5.0%
±5.0%
±3.0%
±3.0%
±3.0%
±2.5%
±2.5%
90%
91%
92%
25.2 ~ 32.4V
50.4 ~ 64.8V
SETUP, RISE TIME
Note.6 1000ms, 30ms / 230VAC
HOLD UP TIME (Typ.)
VOLTAGE RANGE
50ms / 230VAC
15ms / 115VAC at full load
Note.7 90 ~ 264VAC 127 ~ 370VDC
1000ms, 30ms / 115VAC at full load
47 ~ 63Hz
EFFICIENCY (Typ.)
80.5%
AC CURRENT (Typ.)
INRUSH CURRENT (max.)
1A / 115VAC
85.5%
85%
89%
89.5%
0.5A / 230VAC
65A / 230VAC
LEAKAGE CURRENT(max.)
0.75mA / 240VAC
OVERLOAD
105 ~ 150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
5.25 ~ 6.75V
7.88 ~ 10.13V 9.45 ~ 12.15V 12.6 ~ 16.2V 15.75 ~ 20.25V 18.9 ~ 24.3V
Protection type : Shut down o/p voltage, re-power on to recover
PROTECTION
OVER VOLTAGE
WORKING TEMP.
-30 ~ +60℃ (Refer to "Derating Curve")
WORKING HUMIDITY
20% ~ 90% RH non-condensing
-40 ~ +85℃, 10 ~ 95% RH
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
WITHSTAND
VOLTAGE
SAFETY &
ISOLATION RESISTANCE
EMC
(Note. 8)
EMC EMISSION
NOTE
GS40A15
12V
5.34A
FREQUENCY RANGE
CONNECTOR
GS40A12
9V
5A
LOAD REGULATION
OTHERS
GS40A09
7.5V
RATED CURRENT
LINE REGULATION
INPUT
GS40A07
±0.03% / ℃ (0 ~ 50℃)
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
UL60950-1, CSA C22.2, TUV EN60950-1, BSMI CNS14336, CCC GB4943, PSE J60950-1(except for 48V) approved
I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
Compliance to EN55022 class B, EN61000-3-2,3, FCC PART 15 / CISPR22 class B, CNS13438 class B, GB9254, GB17625.1
EMC IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11, light industry level, criteria A
MTBF
DIMENSION
711K hrs min. MIL-HDBK-217F(25℃)
125*50*31.5mm (L*W*H)
0.28Kg; 40pcs/12.02Kg/1.05CUFT
PACKING
PLUG
See page 2 ; Other type available by customer requested
CABLE
See page 2 ; Other type available by customer requested
1. All parameters are specified at 230VAC input, rated load, 25℃ 70% RH ambient.
2. DC voltage: The output voltage set at point measure by plug terminal & 50% load.
3. Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor.
4. Tolerance: includes set up tolerance, line regulation, load regulation.
5. Line regulation is measured from low line to high line at rated load.
6. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.
7. Derating may be needed under low input voltages. Pleas check the derating curve for more details.
8. The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the
EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”
(as available on http://www.meanwell.com)
File Name:GS40-SPEC 2015-06-01
GS40
40W AC-DC Industrial Adaptor
Mechanical Specification
Case No. GS60A
series
Unit:mm
UL1185 16AWG 1000±50mm for 5 ~ 15V
UL1185 18AWG 1800±50mm for 18 ~ 48V
125
31.5
POWER LED
70±10mm
50
C"+"
11±0.5mm
ID 2.1 x OD 5.5
Outside
Inside
-V not connected to AC FG
Plug Assignment
Standard plug: P1J
P1J
Derating Curve
P/N
OUTPUT
CENTER
+
Static Characteristics
100
100
90
80
LOAD (%)
LOAD (%)
80
60
40
70
60
50
20
-30
40
0
10
20
30
40
50
AMBIENT TEMPERATURE (℃)
60
70
(HORIZONTAL)
90
95
100
110
120
140
160
180
200
220
240
264
INPUT VOLTAGE (VAC) 60Hz
File Name:GS40-SPEC 2015-06-01