GS40 40W AC-DC Industrial Adaptor series ■ Features : Universal AC input / Full range No load power consumption<0.3W Energy efficiency Level Ⅴ Comply with EISA 2007, NRCan, AU/NZ MEPS and EU ErP 3 pole AC inlet IEC320-C14 Class I power (with earth pin) Protections: Short circuit / Overload / Over voltage Pass LPS Fully enclosed plastic case LED indicator for power on 2 years warranty (except for 48V) SPECIFICATION ORDER NO. GS40A05-P1J GS40A07-P1J GS40A09-P1J GS40A12-P1J GS40A15-P1J GS40A18-P1J GS40A24-P1J GS40A48-P1J SAFETY MODEL NO. DC VOLTAGE OUTPUT GS40A05 Note.2 5V GS40A18 GS40A24 GS40A48 15V 18V 24V 48V 4.45A 3.34A 2.67A 2.22A 1.67A 0.84A CURRENT RANGE 0 ~ 5A 0 ~ 5.34A 0 ~ 4.45A 0 ~ 3.34A 0 ~ 2.67A 0 ~ 2.22A 0 ~ 1.67A 0 ~ 0.84A RATED POWER (max.) 25W 40W 40W 40W 40W 40W 40W 40W RIPPLE & NOISE (max.) Note.3 100mVp-p 100mVp-p 100mVp-p 100mVp-p 100mVp-p 150mVp-p 180mVp-p 240mVp-p VOLTAGE TOLERANCE Note.4 ±5.0% ±5.0% ±5.0% ±3.0% ±3.0% ±3.0% ±2.5% ±2.5% Note.5 ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±5.0% ±5.0% ±5.0% ±3.0% ±3.0% ±3.0% ±2.5% ±2.5% 90% 91% 92% 25.2 ~ 32.4V 50.4 ~ 64.8V SETUP, RISE TIME Note.6 1000ms, 30ms / 230VAC HOLD UP TIME (Typ.) VOLTAGE RANGE 50ms / 230VAC 15ms / 115VAC at full load Note.7 90 ~ 264VAC 127 ~ 370VDC 1000ms, 30ms / 115VAC at full load 47 ~ 63Hz EFFICIENCY (Typ.) 80.5% AC CURRENT (Typ.) INRUSH CURRENT (max.) 1A / 115VAC 85.5% 85% 89% 89.5% 0.5A / 230VAC 65A / 230VAC LEAKAGE CURRENT(max.) 0.75mA / 240VAC OVERLOAD 105 ~ 150% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed 5.25 ~ 6.75V 7.88 ~ 10.13V 9.45 ~ 12.15V 12.6 ~ 16.2V 15.75 ~ 20.25V 18.9 ~ 24.3V Protection type : Shut down o/p voltage, re-power on to recover PROTECTION OVER VOLTAGE WORKING TEMP. -30 ~ +60℃ (Refer to "Derating Curve") WORKING HUMIDITY 20% ~ 90% RH non-condensing -40 ~ +85℃, 10 ~ 95% RH ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS WITHSTAND VOLTAGE SAFETY & ISOLATION RESISTANCE EMC (Note. 8) EMC EMISSION NOTE GS40A15 12V 5.34A FREQUENCY RANGE CONNECTOR GS40A12 9V 5A LOAD REGULATION OTHERS GS40A09 7.5V RATED CURRENT LINE REGULATION INPUT GS40A07 ±0.03% / ℃ (0 ~ 50℃) 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes UL60950-1, CSA C22.2, TUV EN60950-1, BSMI CNS14336, CCC GB4943, PSE J60950-1(except for 48V) approved I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH Compliance to EN55022 class B, EN61000-3-2,3, FCC PART 15 / CISPR22 class B, CNS13438 class B, GB9254, GB17625.1 EMC IMMUNITY Compliance to EN61000-4-2,3,4,5,6,8,11, light industry level, criteria A MTBF DIMENSION 711K hrs min. MIL-HDBK-217F(25℃) 125*50*31.5mm (L*W*H) 0.28Kg; 40pcs/12.02Kg/1.05CUFT PACKING PLUG See page 2 ; Other type available by customer requested CABLE See page 2 ; Other type available by customer requested 1. All parameters are specified at 230VAC input, rated load, 25℃ 70% RH ambient. 2. DC voltage: The output voltage set at point measure by plug terminal & 50% load. 3. Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor. 4. Tolerance: includes set up tolerance, line regulation, load regulation. 5. Line regulation is measured from low line to high line at rated load. 6. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time. 7. Derating may be needed under low input voltages. Pleas check the derating curve for more details. 8. The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies. (as available on http://www.meanwell.com) File Name:GS40-SPEC 2015-06-01 GS40 40W AC-DC Industrial Adaptor Mechanical Specification Case No. GS60A series Unit:mm UL1185 16AWG 1000±50mm for 5 ~ 15V UL1185 18AWG 1800±50mm for 18 ~ 48V 125 31.5 POWER LED 70±10mm 50 C"+" 11±0.5mm ID 2.1 x OD 5.5 Outside Inside -V not connected to AC FG Plug Assignment Standard plug: P1J P1J Derating Curve P/N OUTPUT CENTER + Static Characteristics 100 100 90 80 LOAD (%) LOAD (%) 80 60 40 70 60 50 20 -30 40 0 10 20 30 40 50 AMBIENT TEMPERATURE (℃) 60 70 (HORIZONTAL) 90 95 100 110 120 140 160 180 200 220 240 264 INPUT VOLTAGE (VAC) 60Hz File Name:GS40-SPEC 2015-06-01