GS120 120W AC-DC Industrial Adaptor series ■ Features : Universal AC input / Full range Built-in active PFC function No load power consumption<0.5W Energy efficiency Level Ⅴ Comply with EISA 2007, NRCan, AU/NZ MEPS and EU ErP 3 pole AC inlet IEC320-C14 Class I power (with earth pin) Protections: Short circuit / Overload / Over voltage / Over temperature Fully enclosed plastic case LED indicator for power on 2 years warranty (except for 48V) SPECIFICATION GS120A12-R7B GS120A15-R7B GS120A20-□ □=R7B,P1M GS120A24-□ □=R7B,P1M GS120A48-□ □=R7B,P1M DC VOLTAGE GS120A12 12V GS120A15 15V GS120A20 20V GS120A24 24V GS120A48 48V RATED CURRENT 8.5A 7A 6A 5A 2.5A CURRENT RANGE 0 ~ 8.5A 0 ~ 7A 0 ~ 6A 0 ~ 5A 0 ~ 2.5A RATED POWER (max.) 102W ORDER NO. SAFETY MODEL NO. OUTPUT 105W 120W 120W 120W RIPPLE & NOISE (max.) Note.2 80mVp-p 120mVp-p 150mVp-p 180mVp-p 240mVp-p VOLTAGE TOLERANCE Note.3 ±5.0% ±5.0% ±5.0% ±3.0% ±2.0% LINE REGULATION Note.4 ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±5.0% ±5.0% ±4.0% ±3.0% ±2.0% LOAD REGULATION SETUP, RISE TIME Note.5 2000ms, 30ms / 230VAC HOLD UP TIME (Typ.) VOLTAGE RANGE Note.6 85 ~ 264VAC 20ms / 230VAC FREQUENCY RANGE EFFICIENCY (Typ.) 89% 89% 90% 91% P1M ----- ----- 88.5% 89.5% 90.5% 0.7A / 230VAC 70A / 230VAC 0.75mA / 240VAC OVERLOAD 105 ~ 160% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed 105 ~ 135% rated output voltage Protection type : Shut down o/p voltage, re-power on to recover OVER VOLTAGE ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS SAFETY & WITHSTAND VOLTAGE ISOLATION RESISTANCE EMC (Note. 7) EMC EMISSION NOTE 1.4A / 115VAC LEAKAGE CURRENT(max.) WORKING TEMP. WORKING HUMIDITY CONNECTOR PF>0.99 / 115VAC at full load 87.5% OVER TEMPERATURE OTHERS PF>0.97 / 230VAC R7B AC CURRENT INRUSH CURRENT (max.) PROTECTION 20ms / 115VAC at full load 120 ~ 370VDC 47 ~ 63Hz POWER FACTOR (Typ.) INPUT 2500ms, 30ms / 115VAC at full load Shut down o/p voltage, re-power on to recover -30 ~ +70℃ (Refer to "Derating Curve") 20% ~ 90% RH non-condensing -40 ~ +85℃, 10 ~ 95% RH ±0.03% / ℃ (0 ~ 45℃) 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes UL60950-1, CSA C22.2, TUV EN60950-1, BSMI CNS14336, CCC GB4943, PSE J60950-1(except for 48V) approved I/P-O/P: 3KVAC I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH Compliance to EN55022 class B, EN61000-3-2,3, FCC PART 15 / CISPR22 class B, CNS13438 class B, GB9254, GB17625.1 EMC IMMUNITY Compliance to EN61000-4-2,3,4,5,6,8,11, light industry level, criteria A MTBF DIMENSION PACKING PLUG 400.7K hrs min. MIL-HDBK-217F(25℃) 167*67*35mm (L*W*H) 0.62Kg; 20pcs/13.4Kg/0.9CUFT See page 2 ; Other type available by customer requested CABLE See page 2 ; Other type available by customer requested 1. All parameters are specified at 230VAC input, rated load, 25℃ 70% RH ambient. 2. Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor. 3. Tolerance: includes set up tolerance, line regulation, load regulation. 4. Line regulation is measured from low line to high line at rated load. 5. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time. 6. Derating may be needed under low input voltage. Please check the derating curve for more details. 7. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies. (as available on http://www.meanwell.com) File Name:GS120-SPEC 2015-06-01 GS120 120W AC-DC Industrial Adaptor Mechanical Specification Case No.GS120A 35 series Unit:mm UL2464 18AWGx4C 1200±50mm 167 30±3mm 67 23 14 POWER LED 35 UL2464 16AWGx2C 1200±50mm 167 30±3mm 67 11 Outside C"+" Inside POWER LED Plug Assignment Standard plug (all models) : power DIN 4 pin with Standard plug(For 20V,24V,48V only) lock type, KYCON KPPX-4P equivalent R7B PIN NO. OUTPUT 2 1 3 4 11 P1M 1,4 +V 2,3 -V P/N OUTPUT CENTER + C"+" ID 2.5 x OD 5.5 Outside AC FG Inside -V connected to AC FG -V connected to AC FG Derating Curve Static Characteristics 100 100 230VAC 85 80 60 LOAD (%) LOAD (%) 80 100VAC 50 40 70 60 50 20 -30 40 10 20 30 40 45 50 60 AMBIENT TEMPERATURE (℃) 70 (HORIZONTAL) 85 95 100 110 120 140 160 180 200 220 240 264 INPUT VOLTAGE (VAC) 60Hz File Name:GS120-SPEC 2015-06-01