MEANWELL GS90_12

GS90
90W AC-DC Single Output Desktop
series
Features :
Universal AC input / Full range
3 pole AC inlet IEC320-C14
Built-in active PFC function, PF>0.91
Protections: Short circuit / Overload / Over voltage / Over temperature
Fully enclosed plastic case
Approvals: UL / CUL / PSE / TUV / BSMI / CCC / CB / FCC / CE
Class power (with earth pin)
Pass LPS
LED indicator for power on
No load power consumption<0.5W
ErP step2 compliant
NRCan compliant
Meet EISA 2007 (Energy Independence and Security Act)
2 years warranty
(except for 48V)
SPECIFICATION
ORDER NO.
SAFETY MODEL NO.
DC VOLTAGE
OUTPUT
INPUT
GS90A19-P1M
GS90A24-P1M
GS90A48-P1M
GS90A19
GS90A24
GS90A48
15V
19V
24V
48V
6A
4.74A
3.75A
1.87A
0 ~ 6.67A
0 ~ 6A
0 ~ 4.74A
0 ~ 3.75A
0 ~ 1.87A
RATED POWER (max.)
80W
90W
90W
90W
90W
100mVp-p
150mVp-p
180mVp-p
240mVp-p
RIPPLE & NOISE (max.) Note.3 80mVp-p
VOLTAGE TOLERANCE Note.4
5.0%
5.0%
4.0%
3.0%
2.0%
LINE REGULATION
Note.5
1.0%
1.0%
1.0%
1.0%
1.0%
LOAD REGULATION
Note.6
5.0%
5.0%
4.0%
3.0%
2.0%
SETUP, RISE TIME
Note.8 1000ms, 20ms / 230VAC
HOLD UP TIME (Typ.)
VOLTAGE RANGE
Note.9 90 ~ 264VAC
20ms / 230VAC
1000ms, 20ms / 115VAC at full load
20ms / 115VAC at full load
127 ~ 370VDC
FREQUENCY RANGE
47 ~ 63Hz
POWER FACTOR (Typ.)
PF>0.91 / 230VAC
EFFICIENCY (Typ.)
88%
AC CURRENT (Typ.)
INRUSH CURRENT (max.)
2A / 115VAC
PROTECTION OVER VOLTAGE
PF>0.95 / 115VAC at full load
89%
89%
91%
70A / 230VAC
1mA / 240VAC
110 ~ 150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
105 ~ 135% rated output voltage
Protection type : Shut down o/p voltage, re-power on to recover
RTH30 > 100
Protection type : Shut down o/p voltage, re-power on to recover
WORKING TEMP.
WORKING HUMIDITY
-30 ~ +50 (Refer to "Derating Curve")
20% ~ 90% RH non-condensing
SAFETY STANDARDS
SAFETY & WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMC
(Note. 7)
EMC EMISSION
EMC IMMUNITY
89.5%
1A / 230VAC
OVER TEMPERATURE
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
NOTE
GS90A15-P1M
GS90A15
CURRENT RANGE
OVERLOAD
CONNECTOR
GS90A12-P1M
6.67A
LEAKAGE CURRENT(max.)
OTHERS
geprUfre
Sicherheit
GS90A12
Note.2 12V
RATED CURRENT
TUV
Rheinland
Product Safety
-40 ~ +85
, 10 ~ 95% RH
0.03% / (0~50 )
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1, BSMI CNS14336, CCC GB4943, J60950-1(except for 48V) approved
I/P-O/P: 3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55022 class B, EN61000-3-2,3, FCC PART 15 / CISPR22 class B, CNS13438 class B, GB9254 class B, GB17625.1
Compliance to EN61000-4-2,3,4,5,6,8,11, light industry level, criteria A
PACKING
PLUG
348.7Khrs min. MIL-HDBK-217F(25 )
145*60*32mm (L*W*H)
0.45Kg; 30pcs/14.05Kg/1CUFT
Standard type P1M: 2.5 * 5.5 * 11mm, tuning fork type, center positive for stock ; Other type available by customer requested
CABLE
See page 2 ; Other type available by customer requested
MTBF
DIMENSION
1. All parameters are specified at 230VAC input, rated load, 25 70% RH ambient.
2. DC voltage: The output voltage set at point measure by plug terminal & 50% load.
3. Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor.
4. Tolerance: includes set up tolerance, line regulation, load regulation.
5. Line regulation is measured from low line to high line at rated load.
6. Load regulation is measured from 10% to 100% rated load
7. The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the
EMC directives.
8. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.
9. Derating may be needed under low input voltages. Pleas check the derating curve for more details.
File Name:GS90-SPEC 2012-03-06
GS90
90W AC-DC Single Output Desktop
Mechanical Specification
Case No. 978A
Unit:mm
UL1185 14AWG 1000 50mm for 12V ~ 15V
UL1185 16AWG 1200 50mm for 19 ~ 48V
145
32
series
70 10mm
60
C"+"
11 0.5mm
POWER LED
ID 2.5 x OD 5.5
Plug Assignment
Standard plug: P1M
P1M
Derating Curve
P/N
OUTPUT
CENTER
+
Static Characteristics
100
100
90
80
80
70
50
LOAD (%)
LOAD (%)
60
40
20
-30
0
10
20
30
40
50
AMBIENT TEMPERATURE ( )
60
70
(HORIZONTAL)
60
50
40
90
95
100
110
120
140
160
180
200
220
240
264
INPUT VOLTAGE (VAC) 60Hz
File Name:GS90-SPEC 2012-03-06