GS90 90W AC-DC Single Output Desktop series Features : Universal AC input / Full range 3 pole AC inlet IEC320-C14 Built-in active PFC function, PF>0.91 Protections: Short circuit / Overload / Over voltage / Over temperature Fully enclosed plastic case Approvals: UL / CUL / PSE / TUV / BSMI / CCC / CB / FCC / CE Class power (with earth pin) Pass LPS LED indicator for power on No load power consumption<0.5W ErP step2 compliant NRCan compliant Meet EISA 2007 (Energy Independence and Security Act) 2 years warranty (except for 48V) SPECIFICATION ORDER NO. SAFETY MODEL NO. DC VOLTAGE OUTPUT INPUT GS90A19-P1M GS90A24-P1M GS90A48-P1M GS90A19 GS90A24 GS90A48 15V 19V 24V 48V 6A 4.74A 3.75A 1.87A 0 ~ 6.67A 0 ~ 6A 0 ~ 4.74A 0 ~ 3.75A 0 ~ 1.87A RATED POWER (max.) 80W 90W 90W 90W 90W 100mVp-p 150mVp-p 180mVp-p 240mVp-p RIPPLE & NOISE (max.) Note.3 80mVp-p VOLTAGE TOLERANCE Note.4 5.0% 5.0% 4.0% 3.0% 2.0% LINE REGULATION Note.5 1.0% 1.0% 1.0% 1.0% 1.0% LOAD REGULATION Note.6 5.0% 5.0% 4.0% 3.0% 2.0% SETUP, RISE TIME Note.8 1000ms, 20ms / 230VAC HOLD UP TIME (Typ.) VOLTAGE RANGE Note.9 90 ~ 264VAC 20ms / 230VAC 1000ms, 20ms / 115VAC at full load 20ms / 115VAC at full load 127 ~ 370VDC FREQUENCY RANGE 47 ~ 63Hz POWER FACTOR (Typ.) PF>0.91 / 230VAC EFFICIENCY (Typ.) 88% AC CURRENT (Typ.) INRUSH CURRENT (max.) 2A / 115VAC PROTECTION OVER VOLTAGE PF>0.95 / 115VAC at full load 89% 89% 91% 70A / 230VAC 1mA / 240VAC 110 ~ 150% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed 105 ~ 135% rated output voltage Protection type : Shut down o/p voltage, re-power on to recover RTH30 > 100 Protection type : Shut down o/p voltage, re-power on to recover WORKING TEMP. WORKING HUMIDITY -30 ~ +50 (Refer to "Derating Curve") 20% ~ 90% RH non-condensing SAFETY STANDARDS SAFETY & WITHSTAND VOLTAGE ISOLATION RESISTANCE EMC (Note. 7) EMC EMISSION EMC IMMUNITY 89.5% 1A / 230VAC OVER TEMPERATURE ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION NOTE GS90A15-P1M GS90A15 CURRENT RANGE OVERLOAD CONNECTOR GS90A12-P1M 6.67A LEAKAGE CURRENT(max.) OTHERS geprUfre Sicherheit GS90A12 Note.2 12V RATED CURRENT TUV Rheinland Product Safety -40 ~ +85 , 10 ~ 95% RH 0.03% / (0~50 ) 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes UL60950-1, TUV EN60950-1, BSMI CNS14336, CCC GB4943, J60950-1(except for 48V) approved I/P-O/P: 3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH Compliance to EN55022 class B, EN61000-3-2,3, FCC PART 15 / CISPR22 class B, CNS13438 class B, GB9254 class B, GB17625.1 Compliance to EN61000-4-2,3,4,5,6,8,11, light industry level, criteria A PACKING PLUG 348.7Khrs min. MIL-HDBK-217F(25 ) 145*60*32mm (L*W*H) 0.45Kg; 30pcs/14.05Kg/1CUFT Standard type P1M: 2.5 * 5.5 * 11mm, tuning fork type, center positive for stock ; Other type available by customer requested CABLE See page 2 ; Other type available by customer requested MTBF DIMENSION 1. All parameters are specified at 230VAC input, rated load, 25 70% RH ambient. 2. DC voltage: The output voltage set at point measure by plug terminal & 50% load. 3. Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor. 4. Tolerance: includes set up tolerance, line regulation, load regulation. 5. Line regulation is measured from low line to high line at rated load. 6. Load regulation is measured from 10% to 100% rated load 7. The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the EMC directives. 8. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time. 9. Derating may be needed under low input voltages. Pleas check the derating curve for more details. File Name:GS90-SPEC 2012-03-06 GS90 90W AC-DC Single Output Desktop Mechanical Specification Case No. 978A Unit:mm UL1185 14AWG 1000 50mm for 12V ~ 15V UL1185 16AWG 1200 50mm for 19 ~ 48V 145 32 series 70 10mm 60 C"+" 11 0.5mm POWER LED ID 2.5 x OD 5.5 Plug Assignment Standard plug: P1M P1M Derating Curve P/N OUTPUT CENTER + Static Characteristics 100 100 90 80 80 70 50 LOAD (%) LOAD (%) 60 40 20 -30 0 10 20 30 40 50 AMBIENT TEMPERATURE ( ) 60 70 (HORIZONTAL) 60 50 40 90 95 100 110 120 140 160 180 200 220 240 264 INPUT VOLTAGE (VAC) 60Hz File Name:GS90-SPEC 2012-03-06