GSM60A series

60W AC-DC High Reliability Medical Adaptor
(
GSM60A
series
for 5~9V)
Features
Applications
Universal AC input / Full range
3 pole AC inlet IEC320-C14
Medical safety approved (2 x MOPP between primary to secondary)
Suitable for BF application with appropriate system consideration
Low leakage current <100uA
No load power consumption<0.1W
Energy efficiency level VI(Except 5~9V for Level V)
Comply with EISA 2007/DoE,NRCan, AU/NZ MEPS,
Mobile clinical workstation
Oral irrigator
Portable hemodialysis machine
Breath Machine
Medical computer monitor
EU ErP and meet CoC Version 5
High efficiency up to 91%
Fanless design with -30~+60℃ working temperature
Class I power (with earth pin)
Protections: Short circuit / Overload / Over voltage/ Over temperature
Fully enclosed plastic case
LED indicator for power on
Optional lock type DC plug
100% full load burn-in test
3 years warranty
Description
GSM6 0 A is a highly reliable, 60W desktop style single-output green medical adaptor series.This product is
a class I power unit(with FG),equipped with a standard IEC320-C14 AC inlet and adopting the input range
from 80VAC to 264VAC. The entire series supplies different models with output voltages between 5VDC
and 48VDC that can satisfy the demands for various types of medical electrical devices. The circuitry
design meets the international medical standards (2*MOPP), having an ultra low leakage current (< 100 u A ),
fitting the medical devices in direct electrical contact with the patients
With the efficiency up to 91% and the extremely low no-load power consumption below 0.1W,GSM60A is
compliant with USA EISA 2007/DoE ,Canada NRCan,Australia and New Zealand MEPS ,EU ErP,and
meet Code of Conduct(CoC) Version 5.The supreme feature allows the adaptor to save the energy when
it is either under the operating mode or the standby mode. The entire series utilizes the 94V-0 flame
retardant plastic case.GSM6 0 A is certified for the international medical safety regulations.
Model Encoding
GSM60 A 05 - P1J
DC plug type
{
P1J: Plug for standard model,2.1ψ x5.5ψ x11mm,c+,tuning fork type
Optional plug type available by customer requested
Output voltage
IEC320-C14 AC inlet
Output wattage
Series name
File Name:GSM60 A -SPEC 2015-06-23
GSM60A
60W AC-DC High Reliability Medical Adaptor
series
SPECIFICATION
ORDER NO.
GSM60A05-P1J GSM60A07-P1J GSM60A09-P1J GSM60A12-P1J GSM60A15-P1J GSM60A18-P1J GSM60A24-P1J GSM60A48-P1J
SAFETY MODEL NO.
DC VOLTAGE
OUTPUT
GSM60A05
Note.2 5V
GSM60A18
GSM60A24
GSM60A48
15V
18V
24V
48V
6A
5A
4A
3.33A
2.5A
1.25A
CURRENT RANGE
0.1 ~ 6A
0.1 ~ 6A
0.1 ~ 6A
0.1 ~ 5A
0.1 ~ 4A
0.1 ~ 3.33A
0.1 ~ 2.5A
0.1 ~ 1.25A
RATED POWER (max.)
30W
45W
54W
60W
60W
60W
60W
60W
RIPPLE & NOISE (max.) Note.3 100mVp-p
100mVp-p
100mVp-p
100mVp-p
100mVp-p
150mVp-p
180mVp-p
240mVp-p
VOLTAGE TOLERANCE Note.4 ±5.0%
±5.0%
±5.0%
±3.0%
±3.0%
±3.0%
±3.0%
±2.5%
LINE REGULATION
Note.5 ±1.0%
±1.0%
±1.0%
±1.0%
±1.0%
±1.0%
±1.0%
±1.0%
±5.0%
±5.0%
±5.0%
±3.0%
±3.0%
±3.0%
±3.0%
±2.5%
89%
90%
91%
25.2 ~ 32.4V
50.4 ~ 64.8V
SETUP, RISE TIME
Note.6 1000ms, 30ms / 230VAC
HOLD UP TIME (Typ.)
VOLTAGE RANGE
Note.7 80 ~ 264VAC
50ms / 230VAC
81.5%
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
1.4A / 115VAC
PROTECTION OVER VOLTAGE
OVER TEMPERATURE
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
SAFETY & ISOLATION LEVEL
WITHSTAND VOLTAGE
EMC
(Note. 8)
ISOLATION RESISTANCE
EMC EMISSION
1500ms, 30ms / 115VAC at full load
15ms / 115VAC at full load
113 ~ 370VDC
47 ~ 63Hz
EFFICIENCY (Typ.)
OVERLOAD
NOTE
GSM60A15
12V
6A
LEAKAGE CURRENT(max.)
CONNECTOR
GSM60A12
9V
6A
FREQUENCY RANGE
OTHERS
GSM60A09
7.5V
RATED CURRENT
LOAD REGULATION
INPUT
GSM60A07
86%
87.5%
88%
88.5%
1A / 230VAC
65A / 230VAC
30A/115VAC
Earth leakage current < 100 uA/264VAC , Touch current < 100 uA/264VAC
105 ~ 160% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
5.25 ~ 6.75V
7.88 ~ 10.13V 9.45 ~ 12.15V 12.6 ~ 16.2V 15.75 ~ 20.25V 18.9 ~ 24.3V
Protection type : Shut down o/p voltage, re-power on to recover
Shut down o/p voltage, re-power on to recover
-30 ~ +60℃ (Refer to "Derating Curve")
20% ~ 90% RH non-condensing
-40 ~ +85℃, 10 ~ 95% RH
±0.03% / ℃ (0 ~ 40℃)
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
ANSI/AAMI ES60601-1 , TUV EN60601-1 approved
Primary-Secondary: 2xMOPP, Primary-Earth:1xMOPP
I/P-O/P:4KVAC I/P-FG:2KVAC O/P-FG:SHORT
I/P-O/P, I/P-FG:100M Ohms / 500VDC / 25℃ / 70% RH
Compliance to EN55011(CISPR11) class B, EN61000-3-2,3, FCC PART 15 class B
EMC IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN60601-1-2, EN61204-3 medical level, criteria A
MTBF
DIMENSION
720K hrs min. MIL-HDBK-217F(25℃ )
125*50*31.5mm (L*W*H)
0.32Kg; 40pcs/ 13.8Kg/1.05CUFT
PACKING
PLUG
CABLE
See page 3 ; Other type available by customer requested
See page 3 ; Other type available by customer requested
1. All parameters are specified at 230VAC input, rated load, 25℃ 70% RH ambient.
2. DC voltage: The output voltage set at point measure by plug terminal & 50% load.
3. Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor.
4. Tolerance: includes set up tolerance, line regulation, load regulation.
5. Line regulation is measured from low line to high line at rated load.
6. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.
7. Derating may be needed under low input voltages. Pleas check the derating curve for more details.
8. The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the
EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”
(as available on http://www.meanwell.com)
File Name:GSM60 A -SPEC 2015-06-23
GSM60A
60W AC-DC High Reliability Medical Adaptor
Derating Curve
series
Static Characteristics
100
100
90
80
LOAD (%)
LOAD (%)
70
50
70
60
50
20
40
-30
0
10
20
30
40
50
60
70
(HORIZONTAL)
AMBIENT TEMPERATURE (℃)
80
90
100
110
120
140
160
180
200
220
240
264
INPUT VOLTAGE (VAC) 60Hz
Mechanical Specification
Case No. GS60A
Unit:mm
UL2464 16AWG 1000 ± 50mm for 5 ~ 15V
UL1185 16AWG 1500 ± 50mm for 18 ~ 48V
125
POWER LED
70±10mm
C"+"
11±0.5mm
ID 2.1 x OD 5.5
Outside
Inside
-V connected to AC FG
Plug Assignment
Standard plug: P1J
P1J
P/N
OUTPUT
CENTER
+
Optronal lock type plug:P2S
SWITCHCRAFT S761K plug equivalent
Installation Manual
Please refer to : http://www.meanwell.com/webnet/search/InstallationSearch.html
File Name:GSM60 A -SPEC 2015-06-23