GS90 series

GS90
90W AC-DC Industrial Adaptor
series
■ Features :
Universal AC input / Full range
Built-in active PFC function
No load power consumption<0.5W
Energy efficiency Level Ⅴ
Comply with EISA 2007, NRCan, AU/NZ MEPS and EU ErP
3 pole AC inlet IEC320-C14
Class I power (with earth pin)
Protections: Short circuit / Overload / Over voltage / Over temperature
Pass LPS
Fully enclosed plastic case
LED indicator for power on
2 years warranty
(except for 48V)
SPECIFICATION
ORDER NO.
SAFETY MODEL NO.
DC VOLTAGE
OUTPUT
INPUT
PROTECTION
GS90A24-P1M
GS90A48-P1M
GS90A24
GS90A48
48V
15V
19V
24V
6.67A
6A
4.74A
3.75A
1.87A
CURRENT RANGE
0 ~ 6.67A
0 ~ 6A
0 ~ 4.74A
0 ~ 3.75A
0 ~ 1.87A
RATED POWER (max.)
80W
90W
90W
90W
90W
RIPPLE & NOISE (max.) Note.3 80mVp-p
100mVp-p
150mVp-p
180mVp-p
240mVp-p
VOLTAGE TOLERANCE Note.4 ±5.0%
±5.0%
±4.0%
±3.0%
±2.0%
LINE REGULATION
Note.5 ±1.0%
±1.0%
±1.0%
±1.0%
±1.0%
LOAD REGULATION
Note.6 ±5.0%
±5.0%
±4.0%
±3.0%
±2.0%
SETUP, RISE TIME
Note.7 1000ms, 20ms / 230VAC
HOLD UP TIME (Typ.)
VOLTAGE RANGE
20ms / 230VAC
20ms / 115VAC at full load
Note.8 90 ~ 264VAC 127 ~ 370VDC
89.5%
91%
FREQUENCY RANGE
47 ~ 63Hz
POWER FACTOR (Typ.)
PF>0.91 / 230VAC
EFFICIENCY (Typ.)
88%
AC CURRENT (Typ.)
INRUSH CURRENT (max.)
2A / 115VAC
1000ms, 20ms / 115VAC at full load
PF>0.95 / 115VAC at full load
89%
89%
1A / 230VAC
70A / 230VAC
LEAKAGE CURRENT(max.)
1mA / 240VAC
OVERLOAD
110 ~ 150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
105 ~ 135% rated output voltage
Protection type : Shut down o/p voltage, re-power on to recover
OVER VOLTAGE
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
SAFETY & WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMC
(Note. 9)
EMC EMISSION
EMC IMMUNITY
NOTE
GS90A19-P1M
GS90A19
Note.2 12V
WORKING TEMP.
WORKING HUMIDITY
CONNECTOR
GS90A15-P1M
GS90A15
RATED CURRENT
OVER TEMPERATURE
OTHERS
GS90A12-P1M
GS90A12
MTBF
DIMENSION
Shut down o/p voltage, re-power on to recover
-30 ~ +50℃ (Refer to "Derating Curve")
20% ~ 90% RH non-condensing
-40 ~ +85℃, 10 ~ 95% RH
±0.03% / ℃ (0~40℃)
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
UL60950-1, CSA C22.2, TUV EN60950-1, BSMI CNS14336, CCC GB4943, PSE J60950-1(except for 48V) approved
I/P-O/P: 3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
Compliance to EN55022 class B, EN61000-3-2,3, FCC PART 15 / CISPR22 class B, CNS13438 class B, GB9254, GB17625.1
Compliance to EN61000-4-2,3,4,5,6,8,11, light industry level, criteria A
348.7K hrs min. MIL-HDBK-217F(25℃)
145*60*32mm (L*W*H)
0.45Kg; 30pcs/14.05Kg/1CUFT
PACKING
PLUG
See page 2 ; Other type available by customer requested
CABLE
See page 2 ; Other type available by customer requested
1. All parameters are specified at 230VAC input, rated load, 25℃ 70% RH ambient.
2. DC voltage: The output voltage set at point measure by plug terminal & 50% load.
3. Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor.
4. Tolerance: includes set up tolerance, line regulation, load regulation.
5. Line regulation is measured from low line to high line at rated load.
6. Load regulation is measured from 10% to 100% rated load.
7. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.
8. Derating may be needed under low input voltages. Pleas check the derating curve for more details.
9. The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the
EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”
(as available on http://www.meanwell.com)
File Name:GS90-SPEC 2015-06-01
GS90
90W AC-DC Industrial Adaptor
Mechanical Specification
Case No. GS90A
Unit:mm
UL1185 14AWG 1000±50mm for 12 ~ 15V
UL1185 16AWG 1200±50mm for 19 ~ 48V
145
32
series
60
70±10mm
C"+"
11±0.5mm
POWER LED
ID 2.5 x OD 5.5
Outside
Inside
-V not connected to AC FG
Plug Assignment
Standard plug: P1M
P1M
Derating Curve
P/N
OUTPUT
CENTER
+
Static Characteristics
100
100
90
80
LOAD (%)
LOAD (%)
80
60
50
40
70
60
50
20
-30
40
0
10
20
30
40
50
AMBIENT TEMPERATURE (℃)
60
(HORIZONTAL)
90
95
100
110
120
140
160
180
200
220
240
264
INPUT VOLTAGE (VAC) 60Hz
File Name:GS90-SPEC 2015-06-01