GS90 90W AC-DC Industrial Adaptor series ■ Features : Universal AC input / Full range Built-in active PFC function No load power consumption<0.5W Energy efficiency Level Ⅴ Comply with EISA 2007, NRCan, AU/NZ MEPS and EU ErP 3 pole AC inlet IEC320-C14 Class I power (with earth pin) Protections: Short circuit / Overload / Over voltage / Over temperature Pass LPS Fully enclosed plastic case LED indicator for power on 2 years warranty (except for 48V) SPECIFICATION ORDER NO. SAFETY MODEL NO. DC VOLTAGE OUTPUT INPUT PROTECTION GS90A24-P1M GS90A48-P1M GS90A24 GS90A48 48V 15V 19V 24V 6.67A 6A 4.74A 3.75A 1.87A CURRENT RANGE 0 ~ 6.67A 0 ~ 6A 0 ~ 4.74A 0 ~ 3.75A 0 ~ 1.87A RATED POWER (max.) 80W 90W 90W 90W 90W RIPPLE & NOISE (max.) Note.3 80mVp-p 100mVp-p 150mVp-p 180mVp-p 240mVp-p VOLTAGE TOLERANCE Note.4 ±5.0% ±5.0% ±4.0% ±3.0% ±2.0% LINE REGULATION Note.5 ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% LOAD REGULATION Note.6 ±5.0% ±5.0% ±4.0% ±3.0% ±2.0% SETUP, RISE TIME Note.7 1000ms, 20ms / 230VAC HOLD UP TIME (Typ.) VOLTAGE RANGE 20ms / 230VAC 20ms / 115VAC at full load Note.8 90 ~ 264VAC 127 ~ 370VDC 89.5% 91% FREQUENCY RANGE 47 ~ 63Hz POWER FACTOR (Typ.) PF>0.91 / 230VAC EFFICIENCY (Typ.) 88% AC CURRENT (Typ.) INRUSH CURRENT (max.) 2A / 115VAC 1000ms, 20ms / 115VAC at full load PF>0.95 / 115VAC at full load 89% 89% 1A / 230VAC 70A / 230VAC LEAKAGE CURRENT(max.) 1mA / 240VAC OVERLOAD 110 ~ 150% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed 105 ~ 135% rated output voltage Protection type : Shut down o/p voltage, re-power on to recover OVER VOLTAGE ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS SAFETY & WITHSTAND VOLTAGE ISOLATION RESISTANCE EMC (Note. 9) EMC EMISSION EMC IMMUNITY NOTE GS90A19-P1M GS90A19 Note.2 12V WORKING TEMP. WORKING HUMIDITY CONNECTOR GS90A15-P1M GS90A15 RATED CURRENT OVER TEMPERATURE OTHERS GS90A12-P1M GS90A12 MTBF DIMENSION Shut down o/p voltage, re-power on to recover -30 ~ +50℃ (Refer to "Derating Curve") 20% ~ 90% RH non-condensing -40 ~ +85℃, 10 ~ 95% RH ±0.03% / ℃ (0~40℃) 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes UL60950-1, CSA C22.2, TUV EN60950-1, BSMI CNS14336, CCC GB4943, PSE J60950-1(except for 48V) approved I/P-O/P: 3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH Compliance to EN55022 class B, EN61000-3-2,3, FCC PART 15 / CISPR22 class B, CNS13438 class B, GB9254, GB17625.1 Compliance to EN61000-4-2,3,4,5,6,8,11, light industry level, criteria A 348.7K hrs min. MIL-HDBK-217F(25℃) 145*60*32mm (L*W*H) 0.45Kg; 30pcs/14.05Kg/1CUFT PACKING PLUG See page 2 ; Other type available by customer requested CABLE See page 2 ; Other type available by customer requested 1. All parameters are specified at 230VAC input, rated load, 25℃ 70% RH ambient. 2. DC voltage: The output voltage set at point measure by plug terminal & 50% load. 3. Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor. 4. Tolerance: includes set up tolerance, line regulation, load regulation. 5. Line regulation is measured from low line to high line at rated load. 6. Load regulation is measured from 10% to 100% rated load. 7. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time. 8. Derating may be needed under low input voltages. Pleas check the derating curve for more details. 9. The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies. (as available on http://www.meanwell.com) File Name:GS90-SPEC 2015-06-01 GS90 90W AC-DC Industrial Adaptor Mechanical Specification Case No. GS90A Unit:mm UL1185 14AWG 1000±50mm for 12 ~ 15V UL1185 16AWG 1200±50mm for 19 ~ 48V 145 32 series 60 70±10mm C"+" 11±0.5mm POWER LED ID 2.5 x OD 5.5 Outside Inside -V not connected to AC FG Plug Assignment Standard plug: P1M P1M Derating Curve P/N OUTPUT CENTER + Static Characteristics 100 100 90 80 LOAD (%) LOAD (%) 80 60 50 40 70 60 50 20 -30 40 0 10 20 30 40 50 AMBIENT TEMPERATURE (℃) 60 (HORIZONTAL) 90 95 100 110 120 140 160 180 200 220 240 264 INPUT VOLTAGE (VAC) 60Hz File Name:GS90-SPEC 2015-06-01