SGA40U series

40W AC-DC High Reliability Slim Wall-mounted Adaptor
■ Features
Ultra slim
Universal AC input / Full range
2 pole USA plug
No load power consumption< 0.075W
Energy efficiency Level Ⅵ
Comply with EISA 2007/DoE
Class Ⅱ power (without earth pin)
Protections: Short circuit / Overload / Over voltage
Fully enclosed plastic case
Pass LPS
3 years warranty
SGA40U
series
■ Applications
Consumer electronic devices
Telecommunication devices
Office facilities
Industrial equipments
■ Description
SGA40U is a 40W ultra slim wall-mounted style single-output green adaptor series, which is compact and
convenient for carry. SGA40U is a class Ⅱ power unit (without FG) equipped with the standard 2-Pin U.S.
plug, accepting the input range from 90VAC to 264VAC. The whole series provides different models with
output voltages ranging between 5VDC and 48VDC that it can satisfy the demands for various types of
consumer electronic devices.
With the efficiency up to 89% and the extremely low no-load power consumption below 0.075W, SGA40U
is compliant with the latest U.S. energy regulation EISA 2007/DoE(Level Ⅵ). The supreme feature allows
the adaptor to save the energy when it is under either the operating mode or the standby mode. The entire
series is approved for international safety regulations; moreover, it adopts the 94V-0 flame retardant plastic
case that it can effectively prevent users from electric hazards.
■ Model Encoding
SGA 40 U 05 - P1J
{
P1J: Plug for standard model, 2.1ψ×5. 5ψ×11mm,
C+ tuning fork type
DC plug type
Optional plug type available per request
Output voltage
US 2 pin AC plug
Output wattage
Series name
File Name:SGA40U-SPEC 2015-05-05
SGA40U
40W AC-DC High Reliability Slim Wall-mounted Adaptor
series
SPECIFICATION
ORDER NO.
SAFETY MODEL NO.
DC VOLTAGE
OUTPUT
SGA40U05-P1J
SGA40U09-P1J
SGA40U12-P1J
SGA40U15-P1J
SGA40U18-P1J
SGA40U24-P1J
SGA40U48-P1J
SGA40U05
SGA40U09
SGA40U12
SGA40U15
SGA40U18
SGA40U24
SGA40U48
48V
Note.2 5V
9V
12V
15V
18V
24V
RATED CURRENT
5A
4.44A
3.33A
2.66A
2.22A
1.67A
0.84A
CURRENT RANGE
0 ~ 5A
0 ~ 4.44A
0 ~ 3.33A
0 ~ 2.66A
0 ~ 2.22A
0 ~ 1.67A
0 ~ 0.84A
RATED POWER (max.)
25W
40W
40W
40W
40W
40W
40W
RIPPLE & NOISE (max.) Note.3 120mVp-p
120mVp-p
120mVp-p
120mVp-p
120mVp-p
150mVp-p
150mVp-p
VOLTAGE TOLERANCE Note.4 ±5.0%
±5.0%
±3.0%
±2.0%
±2.0%
±2.0%
±2.0%
LINE REGULATION
Note.5 ±1.0%
±1.0%
±1.0%
±1.0%
±1.0%
±1.0%
±1.0%
LOAD REGULATION
Note.6 ±5.0%
±5.0%
±3.0%
±2.0%
±2.0%
±2.0%
±2.0%
88%
89%
SETUP, RISE, HOLD UP TIME 500ms, 100ms, 12ms/230VAC
VOLTAGE RANGE
Note.7 90 ~ 264VAC
FREQUENCY RANGE
INPUT
83%
86%
AC CURRENT
INRUSH CURRENT (max.)
1A / 115VAC
0.5A / 230VAC
40A / 115VAC
LEAKAGE CURRENT(max.)
0.25mA / 240VAC
OVERLOAD
110 ~ 250% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
110 ~ 140% rated output voltage
Protection type : Clamp by zener diode, output short
-20 ~ +50℃ (Refer to "Derating Curve")
20% ~ 90% RH non-condensing
-20 ~ +85℃, 10 ~ 95% RH
OVER VOLTAGE
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
SAFETY & WITHSTAND VOLTAGE
EMC
ISOLATION RESISTANCE
(Note. 8)
EMC EMISSION
LIFE
CONNECTOR
NOTE
47 ~ 63Hz
EFFICIENCY (Typ.)
PROTECTION
OTHERS
500ms, 100ms, 12ms/115VAC at full load
86.5%
86.5%
70A / 230VAC
±0.03% / ℃ (0 ~ 40℃)
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
UL60950-1, CSA C22.2 approved
I/P-O/P:4242VDC
I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH
Compliance to FCC PART15/CISPR22 Class B
3 years : 100% load 40℃, 12hours / day
PACKING
PLUG
400Khrs min. MIL-HDBK-217F(25℃)
75.5*32*47.5mm (L*W*H)
165g ; 60pcs / 13kg / CARTON
See page 3 ; Other type available by customer requested
CABLE
See page 3 ; Other type available by customer requested
MTBF
DIMENSION
87%
1.All parameters are specified at 115VAC input, rated load, 25℃ 70% RH ambient.
2.DC voltage: The output voltage set at point measure by plug terminal & 50% load.
3.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor.
4.Tolerance: includes set up tolerance, line regulation, load regulation.
5.Line regulation is measured from low line to high line at rated load.
6.Load regulation is measured from 10% to 100% rated load.
7.Derating may be needed under low input voltages. Please check the static characteristics for more details.
8.The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the
EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”
(as available on http://www.meanwell.com)
File Name:SGA40U-SPEC 2015-05-05
SGA40U
40W AC-DC High Reliability Slim Wall-mounted Adaptor
Derating Curve
series
Static Characteristics
100
90
LOAD (%)
LOAD (%)
100
70
80
70
60
50
40
-20
10
20
30
40
50
90
Ta (℃)
100
115
120
130
140
160
180
200
220
240
264
INPUT VOLTAGE
Mechanical Specification
Unit:mm
75.5
32
UL1571 14AWG 1000±50mm for 5V
UL1571 16AWG 1000±50mm for 9~15V
UL2468 20AWG 1500±50mm for 18~48V
47.5
11±0.5mm
C"+"
ID 2.1 x OD 5.5
Outside
Inside
Plug Assignment
Standard plug: P1J
P1J
P/N
OUTPUT
CENTER
+
Installation Manual
Please refer to : http://www.meanwell.com/webnet/search/InstallationSearch.html
File Name:SGA40U-SPEC 2015-05-05