40W AC-DC High Reliability Medical Adaptor ( GSM40A series for 5~9V) Features Applications Universal AC input / Full range 3 pole AC inlet IEC320-C14 Medical safety approved (2 x MOPP between primary to secondary) Suitable for BF application with appropriate system consideration Low leakage current <100uA No load power consumption<0.1W Energy efficiency level VI(Except 5~9V for Level V) Comply with EISA 2007/DoE,NRCan, AU/NZ MEPS, Mobile clinical workstation Oral irrigator Portable hemodialysis machine Breath Machine Medical computer monitor EU ErP and meet CoC Version 5 High efficiency up to 91% Fanless design with -30~+60℃ working temperature Class I power (with earth pin) Protections: Short circuit / Overload / Over voltage Fully enclosed plastic case LED indicator for power on Optional lock type DC plug 100% full load burn-in test 3 years warranty Description GSM40A is a highly reliable, 40W single-output green medical adaptor series.This product is a class I power unit(with FG),equipped with a standard IEC320-C14 AC inlet and adopting the input range from 80VAC to 264VAC. The entire series supplies different models with output voltages between 5VDC and 48VDC that can satisfy the demands for various types of medical electrical devices. The circuitry design meets the international medical standards (2*MOPP), having an ultra low leakage current (<100 u A), fitting the medical devices in direct electrical contact with the patients. With the efficiency up to 91% and the extremely low no-load power consumption below 0.1W,GSM40A is compliant with USA EISA 2007/DoE ,Canada NRCan,Australia and New Zealand MEPS ,EU ErP,and meet Code of Conduct(CoC) Version 5.The supreme feature allows the adaptor to save the energy when it is either under the operating mode or the standby mode. The entire series utilizes the 94V-0 flame retardant plastic case.GSM40A is certified for the international medical safety regulations. Model Encoding GSM 40 A 05 - P1J DC plug type { P1J: Plug for standard model,2.1ψ x5.5ψ x11mm,c+,tuning fork type Optional plug type available by customer requested Output voltage IEC320-C14 AC inlet Output wattage Series name File Name:GSM40 A -SPEC 2015-06-23 GSM40A 40W AC-DC High Reliability Medical Adaptor series SPECIFICATION ORDER NO. GSM40A05-P1J GSM40A07-P1J GSM40A09-P1J GSM40A12-P1J GSM40A15-P1J GSM40A18-P1J GSM40A24-P1J GSM40A48-P1J SAFETY MODEL NO. DC VOLTAGE OUTPUT GSM40A05 Note.2 5V GSM40A18 GSM40A24 GSM40A48 15V 18V 24V 48V 4.45A 3.34A 2.67A 2.22A 1.67A 0.84A CURRENT RANGE 0.1 ~ 5A 0.1 ~ 5.34A 0.1 ~ 4.45A 0.1 ~ 3.34A 0.1 ~ 2.67A 0.1 ~ 2.22A 0.1 ~ 1.67A 0.1 ~ 0.84A RATED POWER (max.) 25W 40W 40W 40W 40W 40W 40W 40W RIPPLE & NOISE (max.) Note.3 100mVp-p 100mVp-p 100mVp-p 100mVp-p 100mVp-p 150mVp-p 180mVp-p 240mVp-p VOLTAGE TOLERANCE Note.4 ±5.0% ±5.0% ±5.0% ±3.0% ±3.0% ±3.0% ±2.5% ±2.5% LINE REGULATION Note.5 ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±5.0% ±5.0% ±5.0% ±3.0% ±3.0% ±3.0% ±2.5% ±2.5% 89.5% 90% 91% 25.2 ~ 32.4V 50.4 ~ 64.8V SETUP, RISE TIME Note.6 1000ms, 30ms / 230VAC HOLD UP TIME (Typ.) VOLTAGE RANGE Note.7 80 ~ 264VAC 50ms / 230VAC 81% AC CURRENT (Typ.) INRUSH CURRENT (Typ.) 1A / 115VAC PROTECTION OVER VOLTAGE 1500ms, 30ms / 115VAC at full load 15ms / 115VAC at full load 113 ~ 370VDC 47 ~ 63Hz EFFICIENCY (Typ.) OVERLOAD 85.5% 86% 105 ~ 160% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed 5.25 ~ 6.75V 7.88 ~ 10.13V 9.45 ~ 12.15V 12.6 ~ 16.2V 15.75 ~ 20.25V 18.9 ~ 24.3V Protection type : Shut down o/p voltage, re-power on to recover -30 ~ +60℃ (Refer to "Derating Curve") 20% ~ 90% RH non-condensing -40 ~ +85℃, 10 ~ 95% RH EMC IMMUNITY MTBF DIMENSION 88.5% 65A / 230VAC 30A/115VAC Earth leakage current < 100 uA/264VAC , Touch current < 100 uA/264VAC WORKING HUMIDITY SAFETY STANDARDS SAFETY & ISOLATION LEVEL WITHSTAND VOLTAGE EMC (Note. 8) ISOLATION RESISTANCE EMC EMISSION 88% 0.5A / 230VAC WORKING TEMP. ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION NOTE GSM40A15 12V 5.34A LEAKAGE CURRENT(max.) CONNECTOR GSM40A12 9V 5A FREQUENCY RANGE OTHERS GSM40A09 7.5V RATED CURRENT LOAD REGULATION INPUT GSM40A07 ±0.03% / ℃ (0~50℃ ) 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes ANSI/AAMI ES60601-1 , TUV EN60601-1 approved Primary-Secondary: 2xMOPP, Primary-Earth:1xMOPP I/P-O/P:4KVAC I/P-FG:2KVAC O/P-FG:SHORT I/P-O/P, I/P-FG:100M Ohms / 500VDC / 25℃ / 70% RH Compliance to EN55011(CISPR11) class B, EN61000-3-2,3, FCC PART 15 class B Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN60601-1-2, EN61204-3 medical level, criteria A 740K hrs min. MIL-HDBK-217F(25℃ ) 125*50*31.5mm (L*W*H) 0.29Kg; 40pcs/ 12.6 Kg/1.05CUFT PACKING PLUG See page 3 ; Other type available by customer requested CABLE See page 3 ; Other type available by customer requested 1. All parameters are specified at 230VAC input, rated load, 25℃ 70% RH ambient. 2. DC voltage: The output voltage set at point measure by plug terminal & 50% load. 3. Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor. 4. Tolerance: includes set up tolerance, line regulation, load regulation. 5. Line regulation is measured from low line to high line at rated load. 6. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time. 7. Derating may be needed under low input voltages. Pleas check the derating curve for more details. 8. The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on http://www.meanwell.com) File Name:GSM40 A -SPEC 2015-06-23 GSM40A 40W AC-DC High Reliability Medical Adaptor Derating Curve series Static Characteristics 100 100 90 80 LOAD (%) LOAD (%) 80 60 40 70 60 50 20 40 -30 0 10 20 30 50 40 60 70 (HORIZONTAL) AMBIENT TEMPERATURE (℃) 80 90 100 110 120 140 160 180 200 220 240 264 INPUT VOLTAGE (VAC) 60Hz Mechanical Specification Case No. GS60A Unit:mm Ul2464 16AWG 1000 ± 50mm for 5 ~ 7.5V UL1185 16AWG 1000 ± 50mm for 9 ~ 12V UL1185 16AWG 1500 ± 50mm for 15 ~ 48V 125 31.5 70? 10mm C"+" 50 POWER LED 11? 0.5mm ID 2.1 x OD 5.5 Outside Inside -V connected to AC FG Plug Assignment ? Standard plug: P1J P1J ? P/N OUTPUT CENTER + Optronal lock type plug:P2S SWITCHCRAFT S761K plug equivalent Installation Manual Please refer to : http://www.meanwell.com/webnet/search/InstallationSearch.html File Name:GSM40 A -SPEC 2015-06-23