SKE10 series

SKE10
10W DC-DC Regulated Single Output Converter
E¡¡E¡½
¡E¡E
¡E¡E
¡E¡E
¡E¡E
¡EE¡
SPECIFICATION
ORDER NO.
OUTPUT
DC VOLTAGE
5V
12V
15V
24V
CURRENT RANGE
200 ~ 2000mA
84 ~ 840mA
66.6 ~ 666mA
42 ~ 420mA
RATED POWER
10W
60mVp-p
60mVp-p
80mVp-p
RIPPLE & NOISE (max.) Note.2 50mVp-p
LINE REGULATION
Note.3 0.3%
LOAD REGULATION
¡Ó
Note.4 ¡Ó0.5%
¡Ó2.0%
SWITCHING FREQUENCY
200KHz min.
VOLTAGE RANGE
A: 9 ~ 18VDC B: 18 ~ 36VDC C: 36 ~ 72VDC
79%
79%
78%
80%
81%
EFFICIENCY (Typ.)
DC CURRENT
Full load
A: 1100mA B: 530mA
C: 270mA
No load
A: 28mA
C: 8mA
B: 16mA
81%
80%
82%
82%
81%
82%
83%
Pi network
FILTER
PROTECTION
Fuse recommended
OVER CURRENT
160% ~ 250% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
SHORT CIRCUIT
All output equipped with short circuit
Protection type : Hiccup mode, recovers automatically after fault condition is removed
WORKING TEMP.
-25 ~ +71
PROTECTION
(Note. 5)
Features :
2:1 wide input range
4:1 wide input range(option)
1000VDC I/O isolation
3000VDC I/O isolation(option)
Built-in EMI filter
Protections: Short circuit / Overload
Cooling by free air convection
Six-sided shield metal case
100% burn-in test
Low cost / High reliability
Approvals: FCC / CE
2 years warranty
SKE10A- SKE10B- SKE10C- SKE10A- SKE10B- SKE10C- SKE10A- SKE10B- SKE10C- SKE10A- SKE10B- SKE10C12
05
05
05
12
12
15
15
15
24
24
24
VOLTAGE ACCURACY
INPUT
series
¢J (Refer to output load derating curve)
20% ~ 90% RH non-condensing
WORKING HUMIDITY
STORAGE
TEMP.,
HUMIDITY
-25 ~ +105 , 10 ~ 95% RH
ENVIRONMENT
0.03% / (0 ~ 50 )
TEMP. COEFFICIENT
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
VIBRATION
¢J
¢J
¡Ó
WITHSTAND VOLTAGE
I/P-O/P:1KVDC
I/P-O/P: 100M Ohms / 500VDC / 25 / 70% RH
¢J
SAFETY & ISOLATION RESISTANCE
EMC
OTHERS
¢J
EMC EMISSION
EMC IMMUNITY
MTBF
DIMENSION
Compliance to EN55022 Class B, FCC part 15 Class B
Compliance to EN61000-4-2,3,4,5,6,8, light industry level, criteria A
500Khrs min. MIL-HDBK-217F(25 )
WEIGHT
32g
¢J
50.8*25.4*11.2mm or 2"*1"*0.44" inch (L*W*H)
Derating Curve
Pin Configuration
Mechanical Specification
Unit:mm
11.27
1
3
4
2
BOTTOM VIEW
5
£r
1.0 + 0.2/-0.1
10.2 10.2
2.5
15.2
2.5
25.4
10.2 5.1 10.1
20.3
Pin no.
Output
Single
1
2
3
4
5
+ Vi n
- Vi n
+ Vo u t
No Pin
- Vo u t
100
LOAD (%)
50.8
15.3
80
5.8
-25
0
25
50 60 71
Ta (
NOTE
¢J)
100
¢J
1.All parameters are specified at normal input, rated load, 25 70% RH ambient.
2.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor.
3.Line regulation is measured from low line to high line at rated load.
4.Load regulation is measured from 10% to 100% rated load.
5.Please prevent the converter from operating in overload or short circuit condition for more than 30 seconds.
File Name:SKE10-SPEC 2012-07-18