DCW08 8W DC-DC Regulated Dual Output Converter series ■ Features : •2:1 wide input range •1000VDC I/O isolation •Built-in EMI filter •Protections: Short circuit / Overload •Cooling by free air convection •Five-sided shield metal case •100% full load burn-in test •Low cost / High reliability •2 years warranty SPECIFICATION ORDER NO. DCW08A-05 DCW08B-05 DCW08C-05 DCW08A-12 DCW08B-12 DCW08C-12 DCW08A-15 DCW08B-15 DCW08C-15 DC VOLTAGE ±5V ±12V ±15V CURRENT RANGE ±160 ~ ±800mA ±66 ~ ±335mA ±52 ~ ±267mA 60mVp-p 60mVp-p 100uF 47uF RATED POWER 8W RIPPLE & NOISE (max.) Note.2 50mVp-p OUTPUT LINE REGULATION Note.3 ±0.5% LOAD REGULATION Note.4 ±0.5% VOLTAGE ACCURACY ±2.0% SWITCHING FREQUENCY 50KHz min. EXTERNAL CAPACITANCE LOAD (max.) 670uF VOLTAGE RANGE A: 9 ~ 18VDC B: 18 ~ 36VDC C: 36 ~ 72VDC 75% 78% 78% 80% EFFICIENCY (Typ.) INPUT DC CURRENT Full load A: 888mA B: 426mA C: 215mA No load A: 50mA C: 15mA FILTER Pi network Fuse recommended PROTECTION PROTECTION Note.5 B: 25mA 80% 80% 80% 80% 80% 110 ~ 250% rated output load Protection type : Hiccup mode, recovers automatically after fault condition is removed OVERLOAD All output equipped with over current protection SHORT CIRCUIT Protection type : Hiccup mode, recovers automatically after fault condition is removed -40 ~ +71℃ (Refer to "Derating Curve") WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION WITHSTAND VOLTAGE ISOLATION RESISTANCE SAFETY & ISOLATION CAPACITANCE EMC EMC EMISSION EMC IMMUNITY MTBF OTHERS DIMENSION PACKING 20% ~ 90% RH non-condensing -40 ~ +105℃, 10 ~ 95% RH ±0.03% / ℃ (0 ~ 50℃) 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes I/P-O/P:1KVDC I/P-O/P: 100M Ohms / 500VDC / 25℃/ 70% RH 250pF max. Compliance to EN55022 Class B, FCC part 15 Class B Compliance to EN61000-4-2,3,4,5,6,8, light industry level, criteria A 900khrs min. MIL-HDBK-217F (25℃) 31.8*20.3*12.2mm (L*W*H) or 1.25"*0.80"*0.48" inch (L*W*H) 15g Derating Curve Pin Configuration Mechanical Specification Unit:mm(inch) 22 3 BOTTOM VIEW 16 9 14 11 15.2(0.60) 2.5(0.10) 5.0(0.20) 0.6+ 0.1/-0(0.024) Pin No. Output 2&3 9 11 14 16 22 & 23 - Vi n COM - Vo u t + Vo u t COM + Vi n 100 LOAD (%) 2 3.8(0.15) 17.8(0.70) 23 31.8(1.25) 4.6(0.18) 20.3(0.80) 80 -40 0 25 50 60 71 100 12.2(0.48) Ta (℃) NOTE 1.All parameters are specified at normal input, rated load, 25℃ 70% RH ambient. 2.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor. 3.Line regulation is measured from low line to high line at rated load. 4.Load regulation is measured from 20% to 100% rated load. 5.Please prevent the converter from operating in overload or short circuit condition for more than 30 seconds. File Name:DCW08-SPEC 2014-08-13