PS-35 series

PS-35
35W Single Output Switching Power Supply
series
■ Features :
Universal AC input/Full range
Protections:Short circuit/Over load/Over voltage
Cooling by free air convection
100% full load burn-in test
Fixed switching frequency at 60KHz
2 years warranty
..
SPECIFICATION
PS-35-3.3
PS-35-5
PS-35-7.5
PS-35-12
PS-35-13.5
PS-35-15
PS-35-24
PS-35-48
5V
7.5V
12V
13.5V
15V
24V
48V
RATED CURRENT
3.3V
6A
6A
4.7A
3A
2.6A
2.4A
1.5A
0.75A
CURRENT RANGE
0 ~ 6A
0 ~ 6A
0 ~ 4.7A
0 ~ 3A
0 ~ 2.6A
0 ~ 2.4A
0 ~ 1.5A
0 ~ 0.75A
RATED POWER
19.8W
30W
100mVp-p
35.25W
100mVp-p
36W
120mVp-p
35.1W
36W
36W
36W
120mVp-p
150mVp-p
200mVp-p
240mVp-p
3.14 ~ 3.63V
VOLTAGE TOLERANCE Note.3 ±2.0%
4.75 ~ 5.5V
±2.0%
7.13 ~ 8.25V
±2.0%
10.8 ~ 13.2V
±1.0%
21.6 ~ 26.4V
±1.0%
43.2 ~ 52.8V
±1.0%
LINE REGULATION
±0.5%
±0.5%
±0.5%
±0.5%
12.15 ~ 14.85V 13.5 ~ 16.5V
±1.0%
±1.0%
±0.5%
±0.5%
±0.5%
±0.5%
LOAD REGULATION
±1%
±1%
±1%
±0.5%
±0.5%
±0.5%
±0.5%
±0.5%
SETUP, RISE TIME
1200ms, 30ms/230VAC,1200ms,30ms/115VAC at full load
HOLD TIME (Typ.)
50ms/230VAC,10ms/115VAC at full load
VOLTAGE RANGE
90 ~ 264VAC
FREQUENCY RANGE
47 ~ 440Hz
81%
81%
85%
84%
27.6 ~ 32.4V
55.2 ~ 62.4V
MODEL
DC VOLTAGE
OUTPUT
INPUT
RIPPLE & NOISE (max.) Note.2 80mVp-p
VOLTAGE ADJ. RANGE
EFFICIENCY(Typ.)
70%
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
0.75A/115VAC
LEAKAGE CURRENT
OVER LOAD
PROTECTION
OVER VOLTAGE
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
127 ~370VDC
78%
80%
81%
0.5A/230VAC
COLD START 23A/115VAC
<2mA / 240VAC
45A/230VAC
105 ~ 150% rated output power (3.3V:105 ~ 160% rated output power)
Protection type : Hiccup mode, recovers automatically after fault condition is removed.
3.8 ~ 4.95V
5.75 ~ 6.75V 8.63 ~ 10.5V
13.8 ~ 16.2V
Protection type : shut down O/P voltage,re-power on to recover
15.5 ~ 18.2V
17.25 ~ 20.25V
-20 ~ +65℃ (Refer to output load derating curve)
20 ~ 90% RH non-condensing
-20 ~ +85℃, 10 ~ 95% RH
±0.05%/℃ (0 ~ 50℃)
10 ~ 500Hz, 2G 10min./1cycle, Period for 60min.each along X, Y, Z axes
UL60950-1, TUV EN60950-1 Approved
I/P-O/P:3KVAC I/P-FG:2.0KVAC O/P-FG:0.5KVAC
SAFETY & ISOLATION RESISTANCE
EMC
(Note 4)
OTHERS
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B
HARMONIC CURRENT
Compliance to EN61000-3-2,-3
EMS IMMUNITY
MTBF
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, Light industry level, criteria A
588.8Khrs
DIMENSION
101.6*50.8*24mm (L*W*H)
0.124Kg;96PCS/12.9Kg/0.8CUFT
PACKING
NOTE
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
File Name:PS-35-SPEC 2015-05-28
PS-35
35W Outputs Switching Power Supply
Mechanical Specification
series
Unit:mm
101.6
3.175
M1
FG
AC FUSE
T2A/250V
3.175
95.25
M2
SVR
1
2
3
44.45
50.8
CN1
LED
CN2
1
2
3
4
4-
ψ
2
3 max.
24
3.
AC Input Connector (CN1) : JST B3P-VH-B or equivalent
Pin No.
1
3
2
Assignment
AC/L
AC/N
NC
Mating Housing
Terminal
JST VHR
or equivalent
JST SVH-21T-P1.1
or equivalent
DC Output Connector (CN2) : JST B4P-VH-B or equivalent
Pin No.
1,2
3,4
Assignment
+V
-V
Mating Housing
JST VHR
or equivalent
Terminal
JST SVH-21T-P1.1
or equivalent
Block Diagram
fosc : 60KHz
RECTIFIERS
&
FILTER
EMI
FILTER
I/P
RECTIFIERS
&
FILTER
POWER
SWITCHING
+V
-V
DETECTION
CIRCUIT
FG
O.L.P.
CONTROL
O.V.P.
Derating Curve
Output Derating VS Input Voltage
Ta=25℃
100
100
90
80
80
70
LOAD (%)
LOAD (%)
60
40
20
-20
0
10
20
30
40
50
AMBIENT TEMPERATURE (℃)
60 65 70 (HORIZONTAL)
60
50
40
90
95
100
115
120
140
160
180
200
220
240
264
INPUT VOLTAGE (VAC) 60Hz
File Name:PS-35-SPEC 2015-05-28