PD-25 25W Dual Output Switching Power Supply series Features : Universal AC input / Full range Low leakage current<0.5mA Protections:Short circuit/Over load/Over voltage/Over temperature Cooling by free air convection 100% full load burn-in test Fixed switching frequency at 100KHz Low cost High reliability 2 years warranty SPECIFICATION MODEL OUTPUT INPUT PD-25A PD-2512 PD-2515 CH2 CH1 CH2 CH1 CH2 CH1 CH2 CH1 DC VOLTAGE 5V 12V 5V 24V 5V -5V 12V -12V 15V -15V RATED CURRENT 2.1A 1.2A 1.2A 0.8A 2.5A 2.5A 1A 1A 0.8A 0.8A CURRENT RANGE 0.2 ~ 2.5A 0.1 ~ 1.5A 0.2 ~ 2A 0.1 ~ 1A 0.1 ~ 3A 0.1 ~ 2.5A 0.1 ~ 1.2A 0.1 ~ 1.2A 0.1 ~ 1A 0.1 ~ 1A RATED POWER 25W 25.2W 150mVp-p 25W 24W 50mVp-p 50mVp-p 50mVp-p 50mVp-p 50mVp-p 50mVp-p 2.0% 6.0% 2.0% 6.0% 6.0% 6.0% 4.0% 4.0% 4.0% 4.0% LINE REGULATION 0.5% 2.0% 0.5% 2.0% 1.0% 1.0% 0.5% 0.5% 0.5% 0.5% LOAD REGULATION 1.0% 4.0% 1.0% 4.0% 4.0% 4.0% 3.0% 3.0% 3.0% 3.0% SETUP, RISE TIME 250ms, 50ms/230VAC HOLD TIME (Typ.) 100ms/230VAC VOLTAGE RANGE 85 ~ 264VAC FREQUENCY RANGE 47 ~ 63Hz EFFICIENCY(Typ.) 71% AC CURRENT (Typ.) INRUSH CURRENT (Typ.) 0.65A/115VAC 200mVp-p 24W CH2 VOLTAGE TOLERANCE Note.3 RIPPLE & NOISE (max.) Note.2 50mVp-p 50mVp-p 250ms, 30ms/115VAC at full load 16ms/115VAC at full load 120 ~ 370VDC 77% 73% 74% COLD START 32A <0.5mA / 240VAC OVER LOAD Above 105% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS WITHSTAND VOLTAGE SAFETY & ISOLATION RESISTANCE EMI CONDUCTION & RADIATION EMC (Note 4) HARMONIC CURRENT 5.75 ~ 6.75V 13.8 ~ 16.2V 5.75 ~ 6.75V 27.6 ~ 32.4V 5.75 ~ 6.75V -5.75 ~ -6.75V 13.8 ~ 16.2V -13.8 ~ -16.2V 17.3 ~ 20.3V -17.3 ~ -20.3V Protection type : Shut down o/p voltage, re-power on to recover Tj 135 typically (U1) Detect on main control IC Protection type : Shut down o/p voltage, recovers automatically after temperature goes down -10 ~ +60 (Refer to output load derating curve) 20 ~ 90% RH non-condensing -20 ~ +85 , 10 ~ 95% RH 0.03%/ (0 ~ 50 ) ON CH1 output 10 ~ 500Hz, 2G 10min./1cycle, Period for 60min.each along X, Y, Z axes UL60950-1, TUV EN60950-1 Approved I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC Compliance to EN55022 (CISPR22) Class B Compliance to EN61000-3-2,-3 EMS IMMUNITY Compliance to EN61000-4-2,3,4,5, Light industry level, criteria A MTBF 507.9Khrs min. MIL-HDBK-217F (25 107*61*28mm (L*W*H) 0.15Kg; 96pcs/15.9Kg/1.3CUFT DIMENSION PACKING 75% 0.4A/230VAC LEAKAGE CURRENT OVER TEMPERATURE NOTE PD-2505 CH1 PROTECTION OVER VOLTAGE OTHERS PD-25B OUTPUT NUMBER ) 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. File Name:PD-25-SPEC 2005-10-03 PD-25 25W Dual Output Switching Power Supply Mechanical Specification series Unit:mm 107 6.35 94 4-3.5 Dia Mounting Holes 1 2 3 4 AC FUSE 2.5A/250V 3.81 53 61 1 2 3 CN1 CN2 28 To Chassis Grounding AC Input Connector (CN1) : Molex 41791-03 or equivalent Assignment AC/L No Pin AC/N Pin No. 1 2 3 Mating Housing Terminal Molex 2139 or equivalent Molex 2478 or equivalent DC Output Connector (CN2) : Molex 41791-04 or equivalent Pin No. 1 2,3 4 Assignment V1 COM V2 Mating Housing Terminal Molex 2139 or equivalent Molex 2478 or equivalent Block Diagram fosc : 100KHz RECTIFIERS & FILTER EMI FILTER I/P RECTIFIERS & FILTER POWER SWITCHING PWM CONTROL +V COM DETECTION CIRCUIT FG Static Characteristics (A) Output Derating Ta=25 OUTPUT VOLTAGE (V) 100 80 LOAD (%) 60 40 20 +12V 5.0 +5V 0 0 10 20 30 40 50 45 60 55 (HORIZONTAL) (VERTICAL) 300 4.8 250 4.6 200 4.4 150 4.2 +12V 4.0 -10 -10 350 +5V 60 80 100 120 140 160 180 200 220 240 100 OUTPUT RIPPLE (mVp-p) 5.2 50 260 AMBIENT TEMPERATURE ( ) File Name:PD-25-SPEC 2005-10-03 PD-65 65W Dual Output Switching Power Supply series Features : Universal AC input / Full range Low leakage current<0.5mA Protections: Short circuit / Overload / Over voltage Cooling by free air convection 100% full load burn-in test Fixed switching frequency at 65KHz 2 years warranty SPECIFICATION MODEL OUTPUT PD-65B PD-65A OUTPUT NUMBER CH1 CH2 CH1 CH2 DC VOLTAGE 5V 12V 5V 24V RATED CURRENT 5.5A 2.8A 3.5A 2A CURRENT RANGE 0.4 ~ 7A 0.2 ~ 3.2A 0.4 ~ 6A 0.2 ~ 2.6A RATED POWER 61.1W OUTPUT POWER (max.) Rated output power for convection; 72W with 18CFM min. Forced air 65.5W RIPPLE & NOISE (max.) Note.2 50mVp-p 120mVp-p VOLTAGE ADJ. RANGE CH1:4.75 ~ 5.5V VOLTAGE TOLERANCE Note.3 4.0% INPUT 7.0% 150mVp-p 7.0% 1.0% 2.0% 1.0% 2.0% LOAD REGULATION 3.0% 4.0% 3.0% 4.0% SETUP, RISE TIME 800ms, 20ms at full load HOLD UP TIME (Typ.) 60ms at full load VOLTAGE RANGE 90 ~ 264VAC FREQUENCY RANGE 47 ~ 440Hz EFFICIENCY(Typ.) 78% AC CURRENT (Typ.) INRUSH CURRENT (Typ.) 1.5A/115VAC OVERLOAD PROTECTION OVER VOLTAGE WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS WITHSTAND VOLTAGE SAFETY & ISOLATION RESISTANCE EMC EMI CONDUCTION & RADIATION (Note 4) HARMONIC CURRENT EMS IMMUNITY MTBF DIMENSION PACKING NOTE CH1:4.75 ~ 5.5V 4.0% LINE REGULATION LEAKAGE CURRENT OTHERS 50mVp-p 127 ~370VDC 81% 0.9A/230VAC COLD START 20A/115VAC <0.75mA 40A/230VAC 73 ~ 105W rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed. CH1: 5.75 ~ 6.75VDC on CH1 Protection type : Hiccup mode, recovers automatically after fault condition is removed. -10 ~ +60 (Refer to output load derating curve) 20 ~ 90% RH non-condensing -20 ~ +85 , 10 ~ 95% RH 0.04%/ (0 ~ 50 ) on +5V output 10 ~ 500Hz, 2G 10min./1cycle, Period for 60min.each along X, Y, Z axes UL60950-1, TUV EN60950-1 Approved I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC Compliance to EN55022 (CISPR22) Class B Compliance to EN61000-3-2,-3 Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, Light industry level, criteria A 288.1K hrs min. MIL-HDBK-217F (25 127*76*42mm (L*W*H) 0.24Kg; 54pcs/15Kg/1.35CUFT ) 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. 5. Mounting holes M1 and M2 should be grounded for EMI purposes. File Name:PD-65-SPEC 2007-03-14 PD-65 65W Dual Output Switching Power Supply Mechanical Specification series Unit:mm 127 5.6 115.8 5.6 FG M1 M2 CN1 1 64.8 76 CN2 1 2 3 4 5 6 2 AC FUSE F4A/250V SVR1 3. 8 42 4- AC Input Connector (CN1) : Molex 5277-02 or equivalent Pin No. 1 2 Assignment AC/N AC/L Mating Housing Terminal Molex 5195 or equivalent Molex 5194 or equivalent DC Output Connector (CN2) : Molex 5273-06 or equivalent Pin No. 1 2,3 4,5 6 Assignment +V +5V COM NC Mating Housing Terminal Molex 5195 or equivalent Molex 5194 or equivalent Block Diagram fosc : 65KHz POWER SWITCHING RECTIFIERS & FILTER EMI FILTER I/P FG Derating Curve +V RECTIFIERS & FILTER +5V COM DETECTION CIRCUIT PWM CONTROL O.L.P. RECTIFIERS & FILTER O.V.P. Output Derating VS Input Voltage 100 100 90 80 80 70 LOAD(%) LOAD (%) 60 40 20 -10 0 10 20 30 40 50 AMBIENT TEMPERATURE ( ) 60 (HORIZONTAL) 60 50 40 90 100 110 135 155 230 264 INPUT VOLTAGE (V) 60Hz File Name:PD-65-SPEC 2007-03-14