MPT-65 series

M P T- 6 5
65W Triple Output Medical Type
series
■ Features :
Universal AC input / Full range
Low leakage current <250 μA
Protections: Short circuit / Overload / Over voltage
Cooling by free air convection
Medical safety approved (2 x MOPP between primary to secondary)
100% full load burn-in test
Fixed switching frequency at 45KHz
3 years warranty
SPECIFICATION
MODEL
OUTPUT
MPT-65A
CH2
CH3
CH1
CH2
CH3
CH1
CH2
CH3
DC VOLTAGE
5V
12V
-5V
5V
12V
-12V
5V
15V
-15V
RATED CURRENT
5.5A
2.5A
0.5A
5.5A
2.5A
0.5A
5.5A
2A
0.5A
CURRENT RANGE
0.4 ~ 7A
0.2 ~ 3.2A
0 ~ 0.7A
0.4 ~ 7A
0.2 ~ 3.2A
0 ~ 0.7A
0.4 ~ 7A
0.2 ~ 2.6A
0 ~ 0.7A
RATED POWER
60W
OUTPUT POWER (max.)
72W with 18CFM min. Forced air convection
RIPPLE & NOISE (max.) Note.2 60mVp-p
120mVp-p
65W
60mVp-p
60mVp-p
160mVp-p
100mVp-p
60mVp-p
180mVp-p
100mVp-p
CH1:4.5 ~ 5.5V
VOLTAGE TOLERANCE Note.3 ±4.0%
+10,-7%
±5.0%
±4.0%
+10,-7%
±5.0%
±4.0%
+10,-7%
±5.0%
±1.0%
±2.0%
±1.0%
±1.0%
±2.0%
±1.0%
±1.0%
±2.0%
±1.0%
LOAD REGULATION
±3.0%
±4.0%
±1.0%
±3.0%
±4.0%
±1.0%
±3.0%
±4.0%
±1.0%
SETUP, RISE TIME
800ms, 20ms/230VAC
HOLD UP TIME (Typ.)
80ms/230VAC
VOLTAGE RANGE
90 ~ 264VAC
FREQUENCY RANGE
47 ~ 440Hz
EFFICIENCY(Typ.)
74%
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
1.6A/115VAC
PROTECTION
OVER VOLTAGE
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
SAFETY & ISOLATION LEVEL
WITHSTAND VOLTAGE
EMC
(Note 4)
ISOLATION RESISTANCE
EMC EMISSION
EMC IMMUNITY
800ms, 20ms/115VAC at full load
12ms/115VAC at full load
127 ~ 370VDC
74%
74%
1A/230VAC
COLD START 20A/115VAC
40A/230VAC
Note.7 Earth leakage current < 250 μA/264VAC , Touch current < 60 μA/264VAC
OVERLOAD
NOTE
63.5W
LINE REGULATION
LEAKAGE CURRENT
OTHERS
MPT-65C
CH1
VOLTAGE ADJ. RANGE
INPUT
MPT-65B
OUTPUT NUMBER
73 ~ 95W rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
5.75 ~ 6.75VDC on CH1
Protection type : Hiccup mode, recovers automatically after fault condition is removed
-10 ~ +55℃ (Refer to "Derating Curve")
20 ~ 90% RH non-condensing
-20 ~ +85℃, 10 ~ 95% RH
±0.04%/℃ (0 ~ 50℃) on +5V output
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
ANSI/AAMI ES60601-1, TUV EN60601-1, IEC60601-1 approved
Primary-Secondary: 2xMOPP, Primary-Earth:1xMOPP
I/P-O/P:4KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC 1min.
I/P-O/P, I/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
Compliance to EN55011 (CISPR11) Class B, EN61000-3-2,-3
MTBF
Compliance to EN61000-4-2,3,4,5,6,8,11, EN60601-1-2, medical level, criteria A
275.1Khrs min. MIL-HDBK-217F (25℃)
DIMENSION
PACKING
127*76*42mm (L*W*H)
0.27Kg; 54pcs/16.8Kg/1.35CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”
(as available on http://www.meanwell.com)
5. Mounting holes M1 and M2 should be grounded for EMI purposes.
6. Heat Sink HS1,HS2 can not be shorted.
7. Touch current was measured from primary input to DC output.
File Name:MPT-65-SPEC 2015-07-17
M P T- 6 5
65W Triple Output Medical Type
Mechanical Specification
series
Unit:mm
127
115.8
5.6
5.6
HS1
M1
64.8
76
CN2
FS1
1
2
3
4
5
6
AC FUSE
T2A/250V
1
HS2
2
CN1
FS2
AC FUSE
T2A/250V
SVR1
3.
ψ
4-
LED
2 max.
42
8
DC Output Connector (CN2) : Molex 5273-06 or equivalent
AC Input Connector (CN1) : Molex 5277-02 or equivalent
Pin No.
1
2
Assignment
AC/L
AC/N
Mating Housing
Terminal
Molex 5195
or equivalent
Molex 5194
or equivalent
Pin No.
1
2,3
4,5
6
Assignment
+V
+5V
COM
-V
Mating Housing
Terminal
Molex 5195
or equivalent
Molex 5194
or equivalent
: Grounding Required
1.HS1,HS2 cannot be shorted
2.M1 is safety ground
Block Diagram
RECTIFIERS
&
FILTER
EMI
FILTER
I/P
POWER
SWITCHING
FG
Derating Curve
+V
RECTIFIERS
&
FILTER
+5V
RECTIFIERS
&
FILTER
COM
-V
DETECTION
CIRCUIT
PWM
CONTROL
O.L.P.
fosc : 45KHz
RECTIFIERS
&
FILTER
O.V.P.
Static Characteristics
100
100
90
80
80
70
LOAD(%)
LOAD (%)
60
40
20
-10
0
10
20
30
40
50
AMBIENT TEMPERATURE (℃)
60
(HORIZONTAL)
60
50
40
90
100
110
135
155
230 264
INPUT VOLTAGE (V) 60Hz
File Name:MPT-65-SPEC 2015-07-17