M P T- 6 5 65W Triple Output Medical Type series ■ Features : Universal AC input / Full range Low leakage current <250 μA Protections: Short circuit / Overload / Over voltage Cooling by free air convection Medical safety approved (2 x MOPP between primary to secondary) 100% full load burn-in test Fixed switching frequency at 45KHz 3 years warranty SPECIFICATION MODEL OUTPUT MPT-65A CH2 CH3 CH1 CH2 CH3 CH1 CH2 CH3 DC VOLTAGE 5V 12V -5V 5V 12V -12V 5V 15V -15V RATED CURRENT 5.5A 2.5A 0.5A 5.5A 2.5A 0.5A 5.5A 2A 0.5A CURRENT RANGE 0.4 ~ 7A 0.2 ~ 3.2A 0 ~ 0.7A 0.4 ~ 7A 0.2 ~ 3.2A 0 ~ 0.7A 0.4 ~ 7A 0.2 ~ 2.6A 0 ~ 0.7A RATED POWER 60W OUTPUT POWER (max.) 72W with 18CFM min. Forced air convection RIPPLE & NOISE (max.) Note.2 60mVp-p 120mVp-p 65W 60mVp-p 60mVp-p 160mVp-p 100mVp-p 60mVp-p 180mVp-p 100mVp-p CH1:4.5 ~ 5.5V VOLTAGE TOLERANCE Note.3 ±4.0% +10,-7% ±5.0% ±4.0% +10,-7% ±5.0% ±4.0% +10,-7% ±5.0% ±1.0% ±2.0% ±1.0% ±1.0% ±2.0% ±1.0% ±1.0% ±2.0% ±1.0% LOAD REGULATION ±3.0% ±4.0% ±1.0% ±3.0% ±4.0% ±1.0% ±3.0% ±4.0% ±1.0% SETUP, RISE TIME 800ms, 20ms/230VAC HOLD UP TIME (Typ.) 80ms/230VAC VOLTAGE RANGE 90 ~ 264VAC FREQUENCY RANGE 47 ~ 440Hz EFFICIENCY(Typ.) 74% AC CURRENT (Typ.) INRUSH CURRENT (Typ.) 1.6A/115VAC PROTECTION OVER VOLTAGE WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS SAFETY & ISOLATION LEVEL WITHSTAND VOLTAGE EMC (Note 4) ISOLATION RESISTANCE EMC EMISSION EMC IMMUNITY 800ms, 20ms/115VAC at full load 12ms/115VAC at full load 127 ~ 370VDC 74% 74% 1A/230VAC COLD START 20A/115VAC 40A/230VAC Note.7 Earth leakage current < 250 μA/264VAC , Touch current < 60 μA/264VAC OVERLOAD NOTE 63.5W LINE REGULATION LEAKAGE CURRENT OTHERS MPT-65C CH1 VOLTAGE ADJ. RANGE INPUT MPT-65B OUTPUT NUMBER 73 ~ 95W rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed 5.75 ~ 6.75VDC on CH1 Protection type : Hiccup mode, recovers automatically after fault condition is removed -10 ~ +55℃ (Refer to "Derating Curve") 20 ~ 90% RH non-condensing -20 ~ +85℃, 10 ~ 95% RH ±0.04%/℃ (0 ~ 50℃) on +5V output 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes ANSI/AAMI ES60601-1, TUV EN60601-1, IEC60601-1 approved Primary-Secondary: 2xMOPP, Primary-Earth:1xMOPP I/P-O/P:4KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC 1min. I/P-O/P, I/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH Compliance to EN55011 (CISPR11) Class B, EN61000-3-2,-3 MTBF Compliance to EN61000-4-2,3,4,5,6,8,11, EN60601-1-2, medical level, criteria A 275.1Khrs min. MIL-HDBK-217F (25℃) DIMENSION PACKING 127*76*42mm (L*W*H) 0.27Kg; 54pcs/16.8Kg/1.35CUFT 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies. (as available on http://www.meanwell.com) 5. Mounting holes M1 and M2 should be grounded for EMI purposes. 6. Heat Sink HS1,HS2 can not be shorted. 7. Touch current was measured from primary input to DC output. File Name:MPT-65-SPEC 2015-07-17 M P T- 6 5 65W Triple Output Medical Type Mechanical Specification series Unit:mm 127 115.8 5.6 5.6 HS1 M1 64.8 76 CN2 FS1 1 2 3 4 5 6 AC FUSE T2A/250V 1 HS2 2 CN1 FS2 AC FUSE T2A/250V SVR1 3. ψ 4- LED 2 max. 42 8 DC Output Connector (CN2) : Molex 5273-06 or equivalent AC Input Connector (CN1) : Molex 5277-02 or equivalent Pin No. 1 2 Assignment AC/L AC/N Mating Housing Terminal Molex 5195 or equivalent Molex 5194 or equivalent Pin No. 1 2,3 4,5 6 Assignment +V +5V COM -V Mating Housing Terminal Molex 5195 or equivalent Molex 5194 or equivalent : Grounding Required 1.HS1,HS2 cannot be shorted 2.M1 is safety ground Block Diagram RECTIFIERS & FILTER EMI FILTER I/P POWER SWITCHING FG Derating Curve +V RECTIFIERS & FILTER +5V RECTIFIERS & FILTER COM -V DETECTION CIRCUIT PWM CONTROL O.L.P. fosc : 45KHz RECTIFIERS & FILTER O.V.P. Static Characteristics 100 100 90 80 80 70 LOAD(%) LOAD (%) 60 40 20 -10 0 10 20 30 40 50 AMBIENT TEMPERATURE (℃) 60 (HORIZONTAL) 60 50 40 90 100 110 135 155 230 264 INPUT VOLTAGE (V) 60Hz File Name:MPT-65-SPEC 2015-07-17