MPD-65 65W Dual Output Medical Type series Features : Universal AC input / Full range Low leakage current 0.3mA Protections: Short circuit / Overload / Over voltage Cooling by free air convection 100% full load burn-in test Fixed switching frequency at 45KHz 3 years warranty EN60601-1 IEC60601-1 SPECIFICATION MODEL OUTPUT MPD-65A CH1 CH2 CH1 DC VOLTAGE 5V 12V 5V 24V RATED CURRENT 5.5A 2.8A 3.5A 2A CURRENT RANGE 0.4 ~ 7A 0.2 ~ 3.2A 0.4 ~ 6A 0.2 ~ 2.6A RATED POWER 61.1W OUTPUT POWER (max.) 72W with 18CFM min. Forced air convection 7.0% 4.0% 7.0% 1.0% 2.0% 1.0% 2.0% LOAD REGULATION 3.0% 4.0% 3.0% 4.0% 800ms, 20ms/115VAC at full load 80ms/230VAC 12ms/115VAC at full load VOLTAGE RANGE 90 ~ 264VAC 127 ~ 370VDC FREQUENCY RANGE 47 ~ 440Hz EFFICIENCY(Typ.) 75% AC CURRENT (Typ.) INRUSH CURRENT (Typ.) 1.6A/115VAC OVER VOLTAGE WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS WITHSTAND VOLTAGE 78% 1A/230VAC COLD START 20A/115VAC <0.3mA / 264VAC 40A/230VAC 73 ~ 105W rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed 5.75 ~ 6.75VDC on CH1 Protection type : Hiccup mode, recovers automatically after fault condition is removed -10 ~ +55 (Refer to output load derating curve) 20 ~ 90% RH non-condensing -20 ~ +85 , 10 ~ 95% RH 0.04%/ (0 ~ 50 ) on +5V output 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes UL2601-1, TUV EN60601-1, IEC60601-1 approved I/P-O/P:4KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC ISOLATION RESISTANCE I/P-O/P, I/P-FG:100M Ohms / 500VDC / 25 / 70% RH EMI CONDUCTION & RADIATION Compliance to EN55011 (CISPR11) Class B HARMONIC CURRENT EMS IMMUNITY MTBF DIMENSION PACKING NOTE 800ms, 20ms/230VAC HOLD UP TIME (Typ.) PROTECTION OTHERS 150mVp-p 4.0% OVERLOAD (Note 4) 60mVp-p CH1:4.5 ~ 5.5V LINE REGULATION LEAKAGE CURRENT EMC 150mVp-p CH1:4.5 ~ 5.5V VOLTAGE TOLERANCE Note.3 SETUP, RISE TIME SAFETY & CH2 65.5W RIPPLE & NOISE (max.) Note.2 60mVp-p VOLTAGE ADJ. RANGE INPUT MPD-65B OUTPUT NUMBER Compliance to EN61000-3-2,-3 Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN60601-1-2, medical level, criteria A 291.3Khrs min. MIL-HDBK-217F (25 127*76*42mm (L*W*H) 0.25Kg; 54pcs/16Kg/1.35CUFT ) 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies. (as available on http://www.meanwell.com) 5. Mounting holes M1 and M2 should be grounded for EMI purposes. 6. Heat Sink HS1,HS2 can not be shorted. File Name:MPD-65-SPEC 2011-03-31 MPD-65 65W Dual Output Medical Type Mechanical Specification series Unit:mm 127 5.6 115.8 5.6 FG HS1 M1 M2 64.8 76 CN2 FS1 1 2 3 4 5 6 AC FUSE T2A/250V 1 HS2 2 FS2 AC FUSE T2A/250V SVR1 4- 3. 8 2 max. 42 CN1 DC Output Connector (CN2) : Molex 5273-06 or equivalent AC Input Connector (CN1) : Molex 5277-02 or equivalent Pin No. 1 2 Assignment AC/N AC/L Mating Housing Terminal Molex 5195 or equivalent Molex 5194 or equivalent Pin No. Assignment +V 1 +5V 2,3 COM 4,5 6 NC HS1,HS2 can not be shorted Mating Housing Terminal Molex 5195 or equivalent Molex 5194 or equivalent Block Diagram fosc : 45KHz RECTIFIERS & FILTER EMI FILTER I/P POWER SWITCHING FG +V RECTIFIERS & FILTER +5V COM DETECTION CIRCUIT PWM CONTROL O.L.P. RECTIFIERS & FILTER O.V.P. Derating Curve Static Characteristics 100 100 90 80 80 70 LOAD(%) LOAD (%) 60 40 20 -10 0 10 20 30 40 50 AMBIENT TEMPERATURE ( ) 60 (HORIZONTAL) 60 50 40 90 100 110 135 155 230 264 INPUT VOLTAGE (V) 60Hz File Name:MPD-65-SPEC 2011-03-31