90W Single Output Moistureproof Adaptor O WA - 9 0 U IP67 ( for main body ) ■ Features Universal AC input / Full range Built-in active PFC function High efficiency up to 91% Protections: Short circuit / Over current / series ( for 42V,48V,54V ) ( except for 42V, 48V,54V ) ■ Applications LED lighting fixture LED decorative lighting LED office lighting General electronic products in dry or Over voltage / Over temperature damp environment Class Ⅱ power unit, no FG Fanless design, cooling by free air convection No load power consumption <0.15W Energy efficiency Level VI Comply with EISA 2007 DoE and NRCan UL LISTED, suitable for dry and damp locations 5 years warranty ■ Description OWA-90U is one 90W single-output external LED power supply series. Pairing the North American type of AC plug and the prevailing DC connectors, OWA-90U, working like an adaptor, simplifies the connection with LED lighting fixtures without extra wiring efforts. The entire series is certified with the UL LISTED for dry and damp locations. As a class II (without earth pin) design, the enclosure of OWA-90U is a 94V-0 flame retardant plastic case. The interior is fully potted with silicone that enhances the heat dissipation. With the working efficiency up to 91%, OWA-90U is cooled by free air convection; the working temperature ranges from -40℃ to +70℃. ■ Model Encoding OWA - 90 U - 12 - { Blank:Plug for 12V~54V,power DIN 4P with lock type DC plug type P1M:Plug for 20V~54V only,2.5Φx5.5Φx11mm,c+,tuning fork type Output voltage Optional plug type available per request North American type of AC plug Output wattage Series name File Name:OWA-90U-SPEC 2015-05-19 O WA - 9 0 U 90W Single Output Moistureproof Adaptor series SPECIFICATION MODEL OWA-90U-12 OWA-90U-15 OWA-90U-20 OWA-90U-24 OWA-90U-30 OWA-90U-36 OWA-90U-42 OWA-90U-48 OWA-90U-54 DC VOLTAGE 12V 15V 20V 24V 30V 36V 42V 48V 54V CONSTANT CURRENT REGION 7.2 ~ 12V 9 ~ 15V 12 ~ 20V 14.4 ~ 24V 18 ~ 30V 21.6 ~ 36V 25.2 ~ 42V 28.8 ~ 48V 32.4 ~ 54V RATED CURRENT 7.5A 6A 4.5A 3.75A 3A 2.5A 2.15A 1.88A 1.67A RATED POWER 90W 90W 90W 90W 90W 90W 90.3W 90.24W 90.18W RIPPLE & NOISE (max.) Note.2 150mVp-p 150mVp-p 150mVp-p 150mVp-p 200mVp-p 200mVp-p 250mVp-p 250mVp-p 350mVp-p OUTPUT VOLTAGE TOLERANCE Note.3 ±4.0% ±4.0% ±4.0% ±3.0% ±3.0% ±2.0% ±1.0% ±1.0% ±1.0% LINE REGULATION ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% LOAD REGULATION ±1.5% ±1.0% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% SETUP, RISE TIME Note.4 500ms, 80ms at 95% load HOLD UP TIME (Typ.) INPUT 16ms at full load 115VAC / 230VAC 115VAC / 230VAC VOLTAGE RANGE 90 ~ 264VAC FREQUENCY RANGE 47 ~ 63Hz 127 ~ 370VDC POWER FACTOR (Typ.) PF>0.98/115VAC, PF>0.96/230VAC at full load TOTAL HARMONIC DISTORTION THD< 20% when output loading≧60% at 115VAC/230VAC EFFICIENCY (Typ.) 88% 89% 89% 89% 89% 89.5% 89.5% 89.5% 89.5% 230VAC 89% 90% 90% 90% 90% 91% 91% 91% 91% 115VAC AC CURRENT (Typ.) 0.95A / 115VAC INRUSH CURRENT (Typ.) COLD START 30A (twidth=550μs measured at 50% Ipeak) at 115VAC COLD START 60A (twidth=550μs measured at 50% Ipeak) at 230VAC 0.5A / 230VAC MAX. NO. of PSUs on 16A 3 units (circuit breaker of type B) / 6 units (circuit breaker of type C) at 230VAC CIRCUIT BREAKER LEAKAGE CURRENT OVER CURRENT SHORT CIRCUIT PROTECTION <0.125mA / 120VAC Protection type : Constant current limiting, recovers automatically after fault condition is removed Hiccup mode, recovers automatically after fault condition is removed 15 ~ 17V OVER VOLTAGE <0.25mA / 240VAC 95 ~ 108% 17.5 ~ 21V 23 ~ 27V 28 ~ 34V 34 ~ 40V 41 ~ 46V 46 ~ 54V 54 ~ 60V 59 ~ 66V Protection type : Shut down o/p voltage, re-power on to recover OVER TEMPERATURE Shut down o/p voltage, re-power on to recover WORKING TEMP. -40 ~ +70℃ (Refer to "Derating Curve") WORKING HUMIDITY 20 ~ 95% RH non-condensing ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +80℃, 10 ~ 95% RH TEMP. COEFFICIENT ±0.03%/℃ (0 ~ 50℃) VIBRATION 10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes SAFETY STANDARDS Ul8750 listed, CSA C22.2 No. 250.13-12(except for 42V, 48V, 54V); IP67 (for main body ) approved SAFETY & WITHSTAND VOLTAGE EMC ISOLATION RESISTANCE I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH EMC EMISSION MTBF OTHERS DIMENSION PACKING NOTE I/P-O/P:3.75KVAC Compliance to FCC Part15 292.8K hrs min. MIL-HDBK-217F (25℃) 171*63*37.5mm 0.83Kg; 16pcs/14.3Kg/1.01CUFT 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time. File Name:OWA-90U-SPEC 2015-05-19 O WA - 9 0 U 90W Single Output Moistureproof Adaptor series Block Diagram PFC fosc : 50~120KHz PWM fosc : 60~130KHz EMI FILTER & RECTIFIERS I/P RECTIFIERS & FILTER POWER SWITCHING PFC CIRCUIT +V -V O.L.P. O.T.P. DETECTION CIRCUIT O.L.P. PWM & PFC CONTROL O.V.P. Derating Curve Static Characteristics 100 100 90 80 230VAC Input only 70 60 50 LOAD (%) LOAD (%) 80 40 20 -40 -25 -10 0 15 30 50 60 70 (HORIZONTAL) 60 50 40 90 100 125 AMBIENT TEMPERATURE (℃) 135 145 155 165 175 180 200 230 264 INPUT VOLTAGE (V) 60Hz Power Factor Characteristic PF Constant Current Mode 1.00 0.95 0.90 0.85 0.80 0.75 0.70 0.65 0.60 0.55 0.50 0.45 0.40 0.35 0.30 10% 230V 115V 20% 30% 40% 50% 60% LOAD 70% 80% 90% 100% (90W) File Name:OWA-90U-SPEC 2015-05-19 O WA - 9 0 U 90W Single Output Moistureproof Adaptor series EFFICIENCY vs LOAD (48V Model) OWA-90U series possess superior working efficiency that up to 91% can be reached in field applications. 92 91 90 EFFICIENCY (%) 89 88 87 230V 86 115V 85 84 83 82 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% LOAD DRIVING METHODS OF LED MODULE There are two major kinds of LED drive method, "direct drive" and "with LED driver". A typical LED power supply may either work in "constant voltage mode (CV)" or "constant current mode (CC)" to drive the LEDs. Mean Well's LED power supply with CV+ CC characteristic can be operated at both CV mode (with LED driver, at area (A) and CC mode (direct drive, at area (B). In the constant current region, the highest voltage at the output of the driver depends on the configuration of the end systems. Vo(%) 100 (B) Constant Current area (A) Constant Voltage area Should there be any compatibility issues, please contact MEAN WELL. 60 (min.) (C) Hiccup Protection 50 100 Io (%) Typical LED power supply I-V curve File Name:OWA-90U-SPEC 2015-05-19 O WA - 9 0 U 90W Single Output Moistureproof Adaptor Mechanical Specification series Unit:mm Blank Type:(OWA-90U-_) 171 5 5 1500±20 300±20 63 85.5 23 14 31.5 SVT 18AWG×2C 5 2 -ψ 4.5 ※ T case: Max. Case Temperature. 37.5 5 UL2464 18AWG×4C P1M Type:(OWA-90U-_-P1M) 171 5 5 1500±20 300±20 63 31.5 SVT 18AWG×2C 11 85.5 UL2464 16AWGx2C ID2.5xOD5.5 Outside 5 2 -ψ 4.5 Inside ※ T case: Max. Case Temperature. 37.5 5 Input Plug Type All models : NEMA 1-15p male plug Output Plug Assignment Plug for all standard models(12V~ 54V) : Plug for 20V~54V only : power DIN 4 pins with lock type, KYCON KPPX-4P, or equivalent PIN NO. OUTPUT 2 1 3 4 1,4 +V 2,3 -V PIN NO. OUTPUT Outside Inside CENTER +V File Name:OWA-90U-SPEC 2015-05-19 90W Single Output Moistureproof Adaptor O WA - 9 0 U series Recommend Mounting Direction Installation Manual Please refer to : http://www.meanwell.com/search/OWA-90U/OWA-U-E.pdf File Name:OWA-90U-SPEC 2015-05-19