Test Report: OWA-120U-54 120W Single Output Moistureproof Adaptor DESIGN VERIFY TEST Output Function Test Input Function Test Protection Function Test Component Stress Test SAFETY & E.M.C. TEST Safety Test E.M.C. Test RELIABILITY TEST Environment Test 120W Single Output Moistureproof Adaptor OWA-120U series DESIGN VERIFY TEST OUTPUT FUNCTION TEST NO 1 TEST ITEM CONSTANT REGION SPECIFICATION CURRENT 32.4 ~54V TEST CONDITION RESULT I/P: 230VAC 6.7V~53V O/P:LED MODE Ta:25℃ 2 OUTPUT VOLTAGE TOLERANCE -1.0%~1.0% I/P:90 VAC / 264 VAC O/P:FULL/ NO LOAD Ta:25℃ -0.05%~ +0.14% 3 LINE REGULATION -0.5%~0.5% I/P: 100VAC~ 264VAC O/P:FULL LOAD Ta:25℃ 0%~0 % 4 LOAD REGULATION -0.5%~ 0.5% I/P: 230VAC O/P:FULL ~NO LOAD Ta:25℃ -0.05%~0.05 % 5 DYNAMIC LOAD 5400mVp-p I/P: 230VAC O/P: (1)FULL /50% LOAD 50%DUTY / 120HZ (2)FULL /50% LOAD 50%DUTY / 1KHZ Ta:25℃ FULL /50% LOAD 50%DUTY / 120HZ (1) 676mVp-p (2) 448mVp-p FULL /50% LOAD 50%DUTY / 1KHZ 6 OVER/UNDERSHOOT TEST <±5 % I/P: 230VAC O/P:FULL LOAD Ta:25℃ <5 % 7 RIPPLE & NOISE (Max) 350mVp-p I/P: 230VAC O/P:FULL LOAD Ta:25℃ 27.6mVp-p high frequency: low frequency: Model: OWA-120U-54 Test Report 2 / 8 120W Single Output Moistureproof Adaptor 8 SET UP TIME(Max) 230VAC/ 500ms 115VAC/ 500ms INPUT=230VAC/50HZ @ 95% LOAD CH1:Output Voltage CH2:AC Input Voltage 9 RISE TIME (Max) 230VAC/ 80ms 115VAC/ 80ms INPUT=230VAC/50HZ @ 95% LOAD CH1:Output Voltage 10 HOLD UP TIME(Typ ) OWA-120U series I/P: 230 VAC I/P: 115 VAC O/P:95% LOAD Ta:25℃ 230VAC/ 256ms 115VAC/ 224ms INPUT=115VAC/50HZ @ 95% LOAD CH1:Output Voltage CH2:AC Input Voltage I/P: 230 VAC I/P: 115 VAC O/P:95% LOAD Ta:25℃ 230VAC/19.2ms 115VAC/18.4ms INPUT=115VAC/50HZ @ 95% LOAD CH1:Output Voltage 230VAC/ 16ms 115VAC/ 16ms INPUT=230VAC/50HZ @ FULL LOAD CH1:Output Voltage CH2:AC Input Voltage I/P: 230 VAC I/P: 115 VAC O/P:FULL LOAD Ta:25℃ 230VAC/23.2ms 115VAC/22.4ms INPUT=115VAC/50HZ @ FULL LOAD CH1:Output Voltage CH2:AC Input Voltage Model: OWA-120U-54 Test Report 3 / 8 120W Single Output Moistureproof Adaptor OWA-120U series INPUT FUNCTION TEST NO 1 TEST ITEM INPUT VOLTAGE RANGE SPECIFICATION 90VAC~264VAC TEST CONDITION RESULT I/P:TESTING O/P:FULL LOAD Ta:25℃ 87V~264V I/P: TEST:OK (1)LOW-LINE-3V=87 V HIGH-LINE+15%=300 V O/P:FULL/MIN LOAD ON: 30 Sec OFF: 30 Sec 10MIN (2)230VAC ON: 0.5 Sec OFF: 0.5 Sec 20MIN (3)230VAC ON:3Sec OFF:3Sec 12HOURS ( POWER ON/OFF NO DAMAGE ) 2 INPUT FREQUENCY RANGE 47HZ ~63 HZ NO DAMAGE I/P: 90 VAC ~264 VAC O/P:FULL~NO LOAD Ta:25℃ TEST:OK 3 AC CURRENT 1.3A/115VAC 0.65A/230VAC I/P: 115VAC I/P: 230VAC O/P:FULL LOAD Ta:25℃ I =1.12A/ 115VAC I =0.57A/ 230VAC 4 LEAKAGE CURRENT < 0.125mA / 120VAC < 0.25mA / 240VAC I/P: 120VAC I/P: 240VAC O/P:NO LOAD Ta:25℃ L-FG: N-FG: L-FG: N-FG: 5 NO LOAD POWER CONSUMPTION < 0.15W I/P: 230VAC O/P:NO LOAD Ta:25℃ 0.120W 6 TOTAL HARMONIC DISTORTION Total harmonic distortion will be lower than 20% when output loading is 60% or higher at 115V/230VAC I/P: 115VAC I/P: 230VAC O/P:60% LOAD THD: 6.44 %/115VAC THD: 14.47 %/230VAC 7 INRUSH CURRENT(Typ) 30A/115VAC 60A/230VAC Twidth =520 us measured at 50% I/P: 115VAC I/P: 230VAC O/P:FULL LOAD Ta:25℃ I=26.4A/ 115VAC Twidth =386us I=49.2A/ 230VAC Twidth =476us Ipeak COLD START INPUT=115VAC/50HZ @ FULL LOAD CH2:Input current CH1:AC Input Voltage 0.001 0.001 0.003 0.003 mA/120VAC mA/120VAC mA/240VAC mA/240VAC INPUT=230VAC/50HZ @ FULL LOAD CH2:Input current CH1:AC Input Voltage Model: OWA-120U-54 Test Report 4 / 8 120W Single Output Moistureproof Adaptor 8 EFFICIENCY(Typ) OWA-120U series I/P: 115VAC I/P: 230VAC O/P:FULL LOAD Ta:25℃ 89.5%/115VAC 90.5%/230VAC 90.41%/115VAC 90.66%/230VAC EFFICIENCY vs LOAD EFFICIENCY(%) 92% 91% 90% 89% 88% 87% 86% 85% 84% 83% 82% 81% 80% 79% 78% 230V 115V 10% POWER FACTOR 30% 40% 50% 60% LOAD 70% 80% I/P: 115VAC I/P: 230VAC O/P:FULL LOAD Ta:25℃ 0.97/ 115VAC 0.96/ 230VAC 90% 100% PF=0.997/ 115VAC PF=0.971/ 230VAC P.F vs LOAD Constant Current Mode 1.00 0.95 0.90 0.85 0.80 0.75 0.70 0.65 0.60 0.55 0.50 0.45 0.40 0.35 0.30 230V PF 9 20% 115V 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% LOAD Model: OWA-120U-54 Test Report 5 / 8 120W Single Output Moistureproof Adaptor OWA-120U series PROTECTION FUNCTION TEST NO 1 TEST ITEM SPECIFICATION TEST CONDITION RESULT OVER LOAD PROTECTION 95 %~ 108 % I/P: 230VAC O/P:TESTING Ta:25℃ 100.8%/ 230VAC Constant current limiting,recovers automatically after fault condition is removed 2 OVER VOLTAGE PROTECTION 59V~66V I/P: 230VAC O/P:NO LOAD Ta:25℃ 63.4V/ 230VAC Shut down o/p voltage,re-power on to recover 3 OVER PROTECTION NO DAMAGE I/P: 230VAC O/P:FULL LOAD O.T.P. Active Shut down o/p voltage,re-power on to recover 4 SHORT PROTECTION SHORT EVERY OUTPUT 1 HOUR NO DAMAGE I/P: 264VAC O/P:FULL LOAD Ta:25℃ NO DAMAGE Hiccup mode,recovers automatically after fault TEMPERATURE condition is removed COMPONENT STRESS TEST NO 1 TEST ITEM SPECIFICATION TEST CONDITION PWM Transistor ( D to S) or (C to E) Peak Voltage Q 2 Rated 730V/10A I/P:High-Line +3V =267V O/P: (1) Full Load Turn on RESULT (1) 660V (2) 564V (3) 650V (2) Output Short (3) Full load continue Ta:25℃ 2 Diode Peak Voltage Q101 Rated 300V/20A I/P:High-Line +3V =267V O/P: (1) Full Load Turn on (1) 230V (2) 171V (3) 225V (2) Output Short (3) Full load continue Ta:25℃ 3 Input Capacitor Voltage C5 Rated 100u/ 450V I/P:High-Line +3V =267V O/P:(1) Full Load input on/off (2) Min load input on /Off (3) Full Load /Min load Change Ta:25℃ 4 Control IC Voltage Test U1 Rated 28V I/P:High-Line +3V =267V O/P:(1) Full Load input on/off (2) Min load input on /Off (3) Full Load /Min load Change Ta:25℃ 5 PFC Transistor ( D to S) or (C to E) Peak Voltage Q 1 Rated 600V/15A I/P:High-Line +3V =267V O/P: (1) Full Load Turn on (2) Output Short (3) Full load continue Ta:25℃ (1) 442V (2) 436V (3) 442V (1) 17.3V (2) 17.1V (3) 17.1V (1) 504V (2) 494V (3) 466V Model: OWA-120U-54 Test Report 6 / 8 120W Single Output Moistureproof Adaptor OWA-120U series SAFETY TEST NO TEST ITEM SPECIFICATION TEST CONDITION RESULT 1 WITHSTAND VOLTAGE I/P-O/P: 3.75KVAC/min I/P-O/P: 4.2KVAC/min Ta:25℃ I/P-O/P:1.722mA 2 ISOLATION RESISTANCE I/P-O/P:500VDC>100MΩ I/P-O/P: 500VDC Ta:25℃ NO DAMAGE I/P-O/P: >9999MΩ E.M.C TEST NO TEST ITEM SPECIFICATION TEST CONDITION RESULT 1 CONDUCTION FCC Part15 CLASS B I/P:230 VAC (50HZ) O/P:FULL LOAD Ta:25℃ PASS Test by certified Lab 2 RADIATION FCC Part15 CLASS B I/P:230 VAC (50HZ) O/P:FULL LOAD Ta:25℃ PASS Test by certified Lab 3 Test by certified Lab & Test Report Prepare RELIABILITY TEST ENVIRONMENT TEST NO 1 TEST ITEM SPECIFICATION TEMPERATURE RISE TEST MODEL: OWA-120U-36 1. ROOM AMBIENT BURN-IN:2 HRS I/P: 230VAC O/P: FULL LOAD Ta= 27.5℃ 2. HIGH AMBIENT BURN-IN: 2 HRS I/P: 230VAC O/P: FULL LOAD Ta= 52.4℃ TEST CONDITION RESULT NO Position ROOM AMBIENT Ta= 27.5 ℃ HIGH AMBIENT Ta=52.4 ℃ 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 RTH1 RTH2 C11 D6 D10 R7 Q1 Q2 C5 C45 U1 T1 Q101 C105 C106 C110 RTH3 TC 59.8℃ 77.1℃ 74.9℃ 78.9℃ 86.4℃ 84.8℃ 78.8℃ 83.3℃ 73.0℃ 70.2℃ 67.6℃ 74.9℃ 71.6℃ 67.7℃ 65.7℃ 60.4℃ 67.3℃ 61.7℃ 77.2℃ 95.7℃ 94.0℃ 98.6℃ 108.1℃ 106.5℃ 98.0℃ 104.4℃ 92.4℃ 89.1℃ 87.1℃ 95.2℃ 92.4℃ 88.0℃ 86.3℃ 80.4℃ 86.2℃ 81.5℃ Model: OWA-120U-54 Test Report 7 / 8 OWA-120U series 120W Single Output Moistureproof Adaptor 2 LOW TEMPERATURE TURN ON TEST TURN ON AFTER 2 HOUR I/P: 264VAC/100VAC O/P:FULL LOAD Ta= -45℃/-30℃ TEST:OK 3 HIGH HUMIDITY HIGH TEMPERATURE HIGH VOLTAGE TURN ON TEST AFTER 12 HOURS IN CHAMBER ON CONTROL 45℃ I/P: 272VAC O/P:FULL LOAD Ta=45℃ TEST:OK NO DAMAGE HUMIDITY= 95% R.H I/P: 230 VAC O/P:FULL LOAD 4 TEMPERATURE COEFFICIENT ±0.03%/℃(0~50℃) ±0.007%/℃(0~50℃) 5 STORAGE TEMPERATURE TEST 1. Thermal shock Temperature: -45℃~ +90℃ 2. Temperature change rate :25℃ / MIN 3. Dwell time low and high temperature : 30 MIN/EACH 4. Total test cycle:5 CYCLE 5. Input/Output condition: STATIC TEST:OK 6 THERMAL SHOCK TEST 1. Thermal shock Temperature: -45℃~ +50℃ 2. Temperature change rate :25℃ / MIN 3. Dwell time low and high temperature : 30 MIN/EACH 4. Total test cycle:10 CYCLE 5. Input/Output condition: 230VAC/Full Load AC ON/OFF TEST turn on 58 sec,turn off 2 sec; TEST:OK 7 VIBRATION TEST 1 Carton & 1 Set (1) Waveform: Sine Wave (2) Frequency:10~500Hz (3) Sweep Time:12min/sweep cycle (4) Acceleration:5G (5) Test Time:72min in each axis (X.Y.Z) (6) Ta:25℃ 8 CAPACITOR LIFE CYCLE OWA-120U-36:SUPPOSE C105 IS THE MOST CRITICAL COMPONENT (1) I/P: 230VAC O/P:FULL LOAD Ta= 25 ℃ LIFE TIME (2) I/P: 230VAC O/P:FULL LOAD Ta= 45 ℃ LIFE TIME (3) I/P: 230VAC O/P:75% LOAD Ta= 45 ℃ LIFE TIME (4) I/P: 230VAC O/P:50% LOAD Ta= 45 ℃ LIFE TIME 9 MTBF MIL-HDBK-217F TOTAL FAILURE RATE:294.3K HRS 10 DMTBF/Accelerated Life Test Demonstration Mean Time Between Failure (Expected Life): 50000 hours @ TC 70℃ TEST:OK (1) (2) (3) (4) 192200 HRS 66137 HRS 90254 HRS 183065 HRS TEST RESULT TESTER REVIEW APPROVAL PASS ZHANGZJ/ZHUOKB SKY LIUWY Model: OWA-120U-54 Test Report 8 / 8