Harwin Connector Catalog

Datamate Connectors
Female Crimp Trio-Tek
Part numbers are for housings only, see page 25 for
Trio-Tek contacts.
Contacts are rear-insertable.
Crimp inspection window in housing.
Mates with male connectors on pages 27 to 33.
Ideal for volume applications.
DATAMATE L-TEK
Calculation
Single Row
Calculation
double Row
A
B + 5.15
B
(Total no. of contacts - 1) x 2
B
B
2.00
2.00
No. 1 contact
A
B + 5.15
B
Total no. of contacts - 2
2.00
0.50
No. 1 contact
0.50
11.05
11.05
A max
3.45
A max
tools
5.45
Wire Stripping Details
Recommended Hand Crimp Tool – Z80-255
Ø1.10 max
See pages 87 to 89
Instruction sheets available at www.harwin.com/downloads/instructions
3.00 – 2.50
HOW TO ORDER
M80 - 69 X XX 98
Finish
Series code
98
Housing
total No. of contacts
TYPE
0
Single Row
02 to 07, 17
Single Row
1
Double Row
04, 06, 08, 10, 12, 14, 16, 18, 20, 26, 34, 44
Double Row
All dimensions in mm.
www.harwin.com