FEATURES
* Suitable for up to 540°C (1000°F) process temperatures.
* Positively pressurized capsule – isolates all moving parts
of the switch mechanism from the environment. Protects
against corrosion, switch contact oxidation, tampering
and accumulation of deposits leading to pivot hang up.
* Glass-to-metal feed through – internal switch contact
wiring connected to wiring pins which extend through a
sophisticated glass barrier. This prevents air leakage into
the switch mechanism and isolates the wiring electrically.
* 316 construction – switch mechanism is totally enclosed
in a 316 stainless steel container which is hermetically
sealed using a precision pulsed TIG automatic welding
machine.
* Terminal block/high temperature cable welded to the feed
through pins, with RTV corrosion protection – Prevents
shearing from vibration and extends wiring life by minimizing galvanic corrosion occuring on low voltage DC
service.
* 305 mm (12") long exposed wiring leads – allows leads,
which are numerically identified, to be easily field
connected away from the switch enclosure. Eliminates
the requirement to remove the enclosure cover for wiring
connections and safety checks.
* Direct replacement for most standard Magnetrol
switches.
* Proven magnetic coupling principle.
* Designed to the hermetic sealing requirements of
MIL-S-8805D.
* BASEEFA, CENELEC, CSA and FM, approved for
hazardous and non-hazardous locations.
* Available with SPDT or DPDT contacts,
5 A @ 240/120 V AC and 5 A resistive @ 24 V DC.
* Snap action switch mechanism.
* 5 year warranty.
HS
Hermetically sealed
switch
The solution for corrosive and agressive
environments
Terminal block model
APPLICATIONS
•
•
•
•
•
•
•
•
•
•
Feedwater heater, Hi & Lo alarm
Primary steam drip pot
High temperature reactors, Hi & Lo alarm
High temperature ambient conditions
Refinery applications
Offshore salt atmospheres
High temperature separators
Paper processing H2S atmosphere
Chemical plant corrosive atmosphere
Pipeline applications
Wiring lead model
(consult factory for model numbers)
Worldwide level and flow solutions
5 A hermetically sealed switches with terminal block –
max. temp. in non condensing applications 290°C (550°F) ②
Contacts
Anti corrosive coated
Cover
5 A HS switch code / part nr.
switch enclosure
type ④
Model code
tall
SPDT – NEMA 4X (1" NPT entry), Aluminium
1 A hermetically sealed switches with wiring leads –
max. temp. in non condensing applications 540°C (1000°F) ③
Contacts
Repl. partnr.
HM2
SPDT –
NEMA 4X (M20 x 1.5 entry), Aluminium
H7A
One
NEMA 4X (PG 16)① , Aluminium
H6A
contact
NEMA 7/9 standard (1" NPT entry), Cast iron
HS3
enclosure NEMA 7/9 Group B (1" NPT entry), Cast iron
HS4
One
contact
per
89-8301-002
per
Model code
NEMA 4X (1" NPT entry), Aluminium
short
HKB
1A HS switch code / part nr.
H3B
NEMA 7/9 standard (1" NPT entry), Cast iron
H8C
tall
HB1
NEMA 4X (M20 x 1.5 entry), Aluminium
H2H
HB2
NEMA 4X (PG 16), Aluminium
H3H
CENELEC (M20 x 1.5 entry), Cast iron
HB3
NEMA 7/9 standard (1" NPT entry), Cast iron
H8J
CENELEC (3/4" NPT entry), Cast iron
HB4
NEMA 7/9 Group B (1" NPT entry), Cast iron
H8K
SPDT –
H7C
Two
NEMA 4X (PG 16)① , Aluminium
H6C
NEMA 7/9 standard (1" NPT entry), Cast iron
HS7
enclosure NEMA 7/9 Group B (1" NPT entry), Cast iron
HS8
BASEEFA (M20 x 1.5 entry), Cast iron
HB5
BASEEFA (3/4" NPT entry), Cast iron
HB6
CENELEC (M20 x 1.5 entry), Cast iron
HB7
CENELEC (3/4" NPT entry), Cast iron
HB8
NEMA 4X (1" NPT entry), Aluminium
tall
contacts NEMA 4X (PG 16), Aluminium
89-8301-001
(qty. = 1)
per
(qty. = 1)
HKZ
H2Z
NEMA 4X (M20 x 1.5 entry), Aluminium
89-8301-015
HKH
BASEEFA (3/4" NPT entry), Cast iron
tall
(qty. = 1)
Repl. partnr.
H2B
NEMA 4X (PG 16), Aluminium
enclosure NEMA 4X (1" NPT entry), Aluminium
HM6
per
type ④
NEMA 4X (M20 x 1.5 entry), Aluminium
NEMA 4X (M20 x 1.5 entry), Aluminium
contact
Cover
switch enclosure
BASEEFA (M20 x 1.5 entry), Cast iron
DPDT – NEMA 4X (1" NPT entry), Aluminium
One
Anti corrosive coated
89-8301-015
H3Z
NEMA 7/9 standard (1" NPT entry), Cast iron
H8N
enclosure NEMA 7/9 Group B (1" NPT entry), Cast iron
H8P
(qty. = 2)
①
②
CSA approval does not apply to series H5 or HW switches.
③
Only available with wiring leads.
On condensing applications, process temperature downrated
to 400°C (750°F).
④
For exact cover height, refer to corresponding 'model' bulletin.
Aluminium housings are downrated to 400°C (750°F) at non condensing conditions
Consult factory for model codes for models with wiring leads.
On condensing applications, process temperature downrated
to 230°C (450°F).
SELECTION DATA
HS switches may be specified when purchasing new level
controls; or, they may be ordered individually to replace the
switch in existing level controls. When ordered as part of a
new level control, use "Model code" as last part of the
ten-digit model number. To replace an existing mechanism,
use the "replacement part number".
When ordered as a replacement switch, the numeric
ten-digit part number is used with a quantity specified.
Should there be any questions regarding the correct HS
switch code or part number to use, please consult your local
Magnetrol representative.
IMPORTANT:
Check switch temperature and ampere rating
required before substituting the HS switch.
QUALITY ASSURANCE - ISO 9001
THE QUALITY ASSURANCE SYSTEM IN PLACE AT MAGNETROL GUARANTEES THE HIGHEST LEVEL OF QUALITY DURING THE
DESIGN, THE CONSTRUCTION AND THE SERVICE OF CONTROLS.
OUR QUALITY ASSURANCE SYSTEM IS APPROVED AND CERTIFIED TO ISO 9001 AND OUR TOTAL COMPANY IS COMMITTED TO
PROVIDING FULL CUSTOMER SATISFACTION BOTH IN QUALITY PRODUCTS AND QUALITY SERVICE.
PRODUCT WARRANTY
ALL MAGNETROL MECHANICAL LEVEL CONTROLS ARE WARRANTED FREE OF DEFECTS IN MATERIALS AND WORKMANSHIP FOR
5 FULL YEARS FROM THE DATE OF ORIGINAL FACTORY SHIPMENT.
IF RETURNED WITHIN THE WARRANTY PERIOD; AND, UPON FACTORY INSPECTION OF THE CONTROL, THE CAUSE OF THE CLAIM IS DETERMINED TO BE COVERED UNDER THE WARRANTY; THEN, MAGNETROL INTERNATIONAL WILL REPAIR OR REPLACE THE CONTROL AT NO COST TO THE PURCHASER (OR OWNER)
OTHER THAN TRANSPORTATION.
MAGNETROL SHALL NOT BE LIABLE FOR MISAPPLICATION, LABOR CLAIMS, DIRECT OR CONSEQUENTIAL DAMAGE OR EXPENSE ARISING FROM THE INSTALLATION OR USE OF THE EQUIPMENT. THERE ARE NO OTHER WARRANTIES EXPRESSED OR IMPLIED, EXCEPT, SPECIAL WRITTEN WARRANTIES COVERING SOME
MAGNETROL PRODUCTS.
UNDER RESERVE OF MODIFICATIONS
BELGIUM
DEUTSCHLAND
FRANCE
ITALIA
UNITED
KINGDOM
INDIA
Heikensstraat 6, 9240 Zele
Tel. (052) 45.11.11
Fax. (052) 45.09.93
Schloßstraße 76, D-51429 Bergisch Gladbach-Bensberg
Tel. (02204) 9536-0
Fax. (02204) 9536-53
11, Rue A. Einstein, Espace Descartes, 77420 Champs-sur-Marne
adresse postale: 77436 Marne-la-Vallée Cédex 2
Tel. (0) 164.68.58.28
Fax. (0) 164.68.58.27
Via Arese 12, I-20159 Milano
Tel. (02) 607.22.98 (R.A.)
Fax. (02) 668.66.52
Unit 1 Regent Business Centre
Jubilee Road Burgess Hill West Sussex RH 15 9TL
Tel. (01444) 871313
Fax (01444) 871317
B4/115 Safdurjung Enclave, New Delhi 110 029
Tel. 91 (11) 6186211
Fax 91 (11) 6186418
BULLETIN N°:
EFFECTIVE:
SUPERSEDES:
OUR NEAREST REPRESENTATIVE
BE 42-115.6
JANUARY 1997
March 1995