The Kotron® Series 810 R.F. Point Level Sensor is a single
relay, alarm (narrow differential) device which utilizes R.F.
capacitance technology for sensing liquid or bulk materials.
The alarm point is tip sensitive in conductive media, and
adjustable in non-conductive media. There are no moving
parts which come in contact with the medium. These units
are integral systems with the sensing probe mounted with
the electronics.
KOTRON ®
810
R.F. Point Level
Sensor
Excellent rejection of build - up even of
conductive media
FEATURES
* Guard circuit and probe reject build-up of conductive
media.
* Circuitry designed and tested to IEC electrostatic
discharge spec. 801-2.
* Probe is ideal for high pressure applications - rated to
240 bar at 20°C (3500 PSIG at 70°F), 120 bar at 90°C
(1750 PSIG at 200°F).
* Intrinsically safe probe circuitry allows safe use even
with bare probes in hazardous media.
* 5A DPDT relay is usable in most standard alarm
applications.
* LED shows the status of the relay and aids in calibration
and trouble-shooting.
* Zero to 45 second time delay feature eliminates relay
"chatter" due to turbulence.
* Field selectable high level/low level failsafe provides
NO or NC contacts in de-energized state for either failsafe condition.
* Cast aluminum, anti corrosive painted enclosure is rated
CENELEC EEx d (IP 65) NEMA 4X / 7/9.
* Horizontal or vertical mounting.
APPLICATIONS
• Clean or Dirty Liquids
• Viscous Liquid
• Light Slurries
• High Temperature/
Pressure Liquids
AGENCY APPROVALS
• Foods & Beverages
• Powders & Granulars
• Hydrocarbons & Solvents
• Corrosives, Acids &
Caustics
Agency
Approval
CENELEC
EEx d ia II C T6, explosion proof
with intrinsically safe probe
FM/CSA➀
Explosion proof with intrinsically safe probe
circuit
Class I, Div. 1, Groups C & D
Class II, Div. 1, Groups E, F & G
➀ Consult factory for proper selection data.
Worldwide level and flow solutions
PRINCIPLE OF OPERATION
As the media rises and falls in the tank, the amount of
capacitance developed between the probe and the ground
reference also rises and falls. This change in capacitance is
converted into a pulse waveform proportional to the level
change. The amplifier then compares the pulse waveform to
the adjustable set point and changes the state of the relay
when they are equal. In conductive media the amount of
capacitance generated by contact of the probe with the
medium will trip the relay immediately.
PROBE LENGTH VS. DIELECTRIC CONSTANT
If the geometry of the application requires a probe shorter than 305 mm (12") of active length, consult the chart to determine the
minimum dielectric constant in which it can be used.
MINIMUM IMMERSED
PROBE LENGHT IN mm (inches)
305 (12)
279 (11)
254 (10)
229 (9)
203 (8)
178 (7)
152 (6)
127 (5)
102 (4)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
MINIMUM REQUIRED DIELECTRIC CONSTANT (EPSILON) OF MATERIAL
MOUNTING
Overflow protector
Build up
High Alarm
Low Alarm
2
17
18
19
20
EXPEDITE SHIP PLAN (ESP)
Magnetrol has implemented a quick delivery programme ‘ESP’, for the most popular units and options. The colour coded selections
represent those that benefit from the shortest lead times.
SELECTION DATA
A complete measuring system consists of:
1. Order code for standard KOTRON® electronics - non hazardous area
INPUT POWER
1
240 V AC
2
224 V DC
0
120 V AC
3
212 V DC
HOUSING MATERIALS OF CONSTRUCTION
D
Y
Dual cable entry 3/4" NPT - anti corrosive coated aluminium
Single cable entry 3/4" NPT - stainless steel
PROBE SELECTION
1
2
8 1 0
0
0 5
Guarded probe 457 mm (18")
Guarded probe 914 mm (36")
complete order code for standard KOTRON® 810
0
2. Order code for CENELEC KOTRON® electronics - hazardous area
INPUT POWER
1
240 V AC
2
224 V DC
0
120 V AC
3
212 V DC
HOUSING MATERIALS OF CONSTRUCTION
V
W
U
S
5
3/4" NPT dual cable entry - anti corrosive coated aluminium
M 20 x 1.5 dual cable entry - anti corrosive coated aluminium
PG 13.5 dual cable entry - anti corrosive coated aluminium
PG 16 dual cable entry - anti corrosive coated aluminium
3/4" NPT single cable entry - stainless steel
PROBE SELECTION
A
B
8 1 0
0
0 5
0
Guarded probe 457 mm (18")
Guarded probe 914 mm (36")
complete order code for CENELEC KOTRON® 810
ELECTRICAL SPECIFICATIONS
Description
Specification
Supply Voltage
Power Consumption
Zero Range
Fixed Differential
240/120 V AC, 50-60 Hz – 24/12 V DC
240/120 V AC, less than 5 V A – 24 /12V DC, 1 Watt max.
0 pF (Min.) to 500 pF (Max.)
0.5 pF
Reversible DPDT – 250 V AC 5A Resistive
Reversible DPDT – 30 V DC 5A Resistive
100 milliseconds
-40°C to + 70°C (-40°F to + 160°F)
240 bar@ 20°C (3500 PSIG @ 70°F)
120 Bar @ 90°C (1750 PSIG @ 200°F)
± 0.018 pF/ °C
± 0.01 pF/ °F
per IEC spec. 801-2
Output Relays
Response Time
Ambient Temperature at Electronics
Operating Process
Pressure/Temperature
Temperature Coefficient of Setpoint
-40°C to +70°C (-40°F to +160°F)
Electrostatic Discharge Protection
AC
DC
3
DIMENSIONS IN mm (inches)
Ø 118 (4.63)
Rotation Clearance
dual cable entry: 87 (3.41)
single cable entry: 76 (3.00)
70
(2.75)
3/4" NPT
Thread
104
(4.11)
3/4" NPT or
M 20 x 1.5
PG 13.5/16
(For dual entry:
one entry plugged)
150
(6.00)
Guard Length
455 or 915
(18.00) (36.00)
305 or 765
(12.00) (30.00)
Active Length
QUALITY ASSURANCE - ISO 9001
THE QUALITY ASSURANCE SYSTEM IN PLACE AT MAGNETROL GUARANTEES THE HIGHEST LEVEL OF QUALITY DURING THE
DESIGN, THE CONSTRUCTION AND THE SERVICE OF CONTROLS.
OUR QUALITY ASSURANCE SYSTEM IS APPROVED AND CERTIFIED TO ISO 9001 AND OUR TOTAL COMPANY IS COMMITTED TO
PROVIDING FULL CUSTOMER SATISFACTION BOTH IN QUALITY PRODUCTS AND QUALITY SERVICE.
PRODUCT WARRANTY
ALL MAGNETROL ELECTRONIC AND ULTRASONIC LEVEL CONTROLS ARE WARRANTED FREE OF DEFECTS IN MATERIALS AND
WORKMANSHIP FOR ONE FULL YEAR FROM THE DATE OF ORIGINAL FACTORY SHIPMENT. IF RETURNED WITHIN THE WARRANTY PERIOD; AND, UPON FACTORY
INSPECTION OF THE CONTROL, THE CAUSE OF THE CLAIM IS DETERMINED TO BE COVERED UNDER THE WARRANTY; THEN, MAGNETROL INTERNATIONAL WILL
REPAIR OR REPLACE THE CONTROL AT NO COST TO THE PURCHASER (OR OWNER) OTHER THAN TRANSPORTATION.
MAGNETROL SHALL NOT BE LIABLE FOR MISAPPLICATION, LABOR CLAIMS, DIRECT OR CONSEQUENTIAL DAMAGE OR EXPENSE ARISING FROM THE INSTALLATION OR USE OF THE EQUIPMENT. THERE ARE NO OTHER WARRANTIES EXPRESSED OR IMPLIED, EXCEPT, SPECIAL WRITTEN WARRANTIES COVERING SOME
MAGNETROL PRODUCTS.
UNDER RESERVE OF MODIFICATIONS
BELGIUM
DEUTSCHLAND
FRANCE
ITALIA
UNITED
KINGDOM
INDIA
Heikensstraat 6, 9240 Zele
Tel. (052) 45.11.11
Fax. (052) 45.09.93
Schloßstraße 76, D-51429 Bergisch Gladbach-Bensberg
Tel. (02204) 9536-0
Fax. (02204) 9536-53
11, Rue A. Einstein, Espace Descartes, 77420 Champs-sur-Marne
adresse postale : 77436 Marne-la-Vallée Cédex 2
Tel. (0) 164.68.58.28
Fax. (0) 164.68.58.27
Via Arese 12, I-20159 Milano
Tel. (02) 607.22.98 (R.A.)
Fax. (02) 668.66.52
Unit 1 Regent Business Centre
Jubilee Road Burgess Hill West Sussex RH 15 9TL
Tel. (01444) 871313
Fax (01444) 871317
B4/115 Safdurjung Enclave, New Delhi 110 029
Tel. 91 (11) 6186211
Fax 91 (11) 6186418
BULLETIN N°:
EFFECTIVE:
SUPERSEDES:
OUR NEAREST REPRESENTATIVE
BE 50-102.2
APRIL 1996
October 1994