XMC0 Series Definite Purpose Contactors Description HOMER XMC0 series high performance definite purpose contactors (1pole, 1-pole+shunt, 2-pole, 3-pole(optional Auxiliary Contact Blocks or Microswitch Blocks available, from 25A to 90A ) are ideal for (HVAC) air conditioning, refrigeration, heating, data processing, welding, elevators, hoists & cranes, washing machine, lighting, pools & spas and food service equipments. XMC0 series definite purpose contactors meet IEC 60947-41, GB 14048.4 and UL508 standard. Features 1. Tools-free accessories make quick & easy snap on. 2. Various terminal optional for specific application. 3. Universal mounting plate allows an easy replacement other brands. 4. Heavy duty Silver Metal Oxide composition contacts with longer electrical endurance. 5. Coils are Class F (155℃) temperature insulated with wide range of voltages and 50/60Hz ratings. 6. Different with main competitors,our1&2P contactors have the options to add coil cover to effectively protect the coil from being damaged by outer force. 7. UL and CCC approved, some models SEMKO, KETI or TÜV plus. Type model nomenclature - Ordering Information XM 1 C 2 0 – 3 25 4 3. 5 E 6 B 7 B 8 C 30 9 10 F Q 11 12 Number digit 1: Manufacturer’s code XM – Xiamen Hongmei Electronic Co., Ltd. Number digit 2: Product Type C – Contactor Number digit 3: Design Sequence Number – 0 1 □ □ 13 14 □ 15 Number digit 4: Full Load Amperes (FLA) – 25, 32, 40, 50, 63, 75 or 90 25 – 25A 32 – 32A 40 – 40A 50 – 50A 63 – 63A 75 – 75A 90 – 90A Number digit 5: Number of Poles – 1, 2, 3, 3A, 7 Number digit 5 1 Number of poles 1-pole+shunt 2 3 2-pole 3-pole 3A 2-pole (at 3p frame) 7 1-pole Number digit 6: Coil Voltage – E, F, I, L, N Number digit 6 50Hz Coil voltage 60Hz E 24VAC 24VAC F 110-120VAC 110-120VAC I 208-220VAC 208-240VAC L -277VAC Number digit 7: Mounting plate – A, B (B: Normal) A – Plastic base(For 25-40FLA only, not recommend) B – Metal plate Number digit 8: Cover – A, B (B:Normal) A – Long cover(For 25-40FLA only, not recommend) B – Short cover Number digit 9: Terminal – A, B, C, D, E, F A – Screw w/ quick connect (For 25-40FLA only) B – Sems clamp w/ quick connect (For 25-40FLA only) C – Slotted & Hex head washer w/ quick connect D – Box lug w/ quick connect E – Box lug w/ quick connect (Line side) Slotted & Hex head washer w/ quick connect (Load side) 2 N 380-415VAC 440-480VAC F – Slotted & Hex head washer w/ quick connect (Line side) Box lug w/ quick connect (Load side) Number digit 10: Auxiliary Contact Blocks or Microswitch Blocks (for 3-pole) (Left & Right) side (SPDT is Microswitch) – 0, 1, 3, 4, 5, 6, 1P, 3P, 4P, 5P, 6P, L, L1, L2, R, R1, R2 Aux. contact Blocks or Microswitch Aux. contact Blocks or Microswitch Blocks on left side Blocks on right side 0 None (Standard Type) 0 None (Standard Type) 1 1NC+1NO, 0.250” quick connect terminal 1 1NC+1NO, 0.250” quick connect terminal 3 1NC, 0.250” quick connect terminal 3 1NC, 0.250” quick connect terminal 4 1NO, 0.250” quick connect terminal 4 1NO, 0.250” quick connect terminal 5 2NC, 0.250” quick connect terminal 5 2NC, 0.250” quick connect terminal 6 2NO, 0.250” quick connect terminal 6 2NO, 0.250” quick connect terminal 1P 1NC+1NO, pressure plate screw 1P 1NC+1NO, pressure plate screw 3P 1NC, pressure plate screw 3P 1NC, pressure plate screw 4P 1NO, pressure plate screw 4P 1NO, pressure plate screw 5P 2NC, pressure plate screw 5P 2NC, pressure plate screw 6P 2NO, pressure plate screw 6P 2NO, pressure plate screw L 2 SPDT R 2 SPDT L1 1 SPDT, left side(position 1) of microswitch block R1 1 SPDT, left side(position 1) of microswitch block L2 1 SPDT, right side(position 2) of microswitch block R2 1 SPDT, right side(position 2) of microswitch block For example: 34P – 1NC pressure plate screws w/ quick connect on left side, 1NO pressure plate screws on right side 56 – 2NC pressure plate screws w/ quick connect on left side, 2NO pressure plate screws w/ quick connect on right side LR1 – 2SPDT on left side, 1SPDT(position 1) on right side 3R2 – 1NC pressure plate screws w/ quick connect on left side, 1SPDT(position 2) on right side Note: If “00” will be the final digit(s) in selection, omit from model nomenclature. Number digit 11: Coil terminals – Blank, F Blank – Dual terminals without screws in 1- and 2- pole models and Single terminals with screws in 3-pole models F – Dual terminals with screws in 3- pole models Number digit 12: Power quick terminals – Blank, G, Q Blank – Quad terminals in 1-and 2- pole models and Dual terminals in 3-pole models G – Without any terminals Q – Dual terminals at the side near coil terminal and Quad terminals at the other side in 3-pole 25-40FLA models 3 Number digit 13: Nameplate – Blank, T Blank – Nameplate shows actual product rating T – Nameplate shows derated product rating Number digit 14: Contact construction style (for 50/63 FLA) – Blank, Z Blank – Flat construction in shape Z – Bend construction in shape (new design) Number digit 15: Option Customer assigned suffix “X” where “X” may be any alphanumeric character or any combined alphanumeric character. Characteristics IEC60947-4-1, GB14048.4, UL508 UL(USR/CNR) and CCC Some models SEMKO, KETI or TÜV plus Total climate tropical use “TH” Vertical or Horizental (Metal/Plastic base mounting) -25℃~+70℃ -40℃~+70℃ 90-95%RH at 40℃ 3 Conforming to standard Approvals Protective treatment Operating position Ambient temperature operation storage ℃ ℃ Relative humidity Pollution degree Performance XMC0- Poles 1 2 3 3A 7 Rated insulation voltage V 690 Rated operating voltage V 240/277,480,600 (60Hz) or 230,400 (50Hz) Rate current(AC-8a) A 25 32 40 50 63 75 90 Conventional free air thermal current (Ith) A 32 40 50 63 80 94 120 Full Load Ampere(FLA) A 25 32 40 50 63 75 90 Resistive Amps Rating(RES) A 35 40 50 63 75 94 120 Switching frequency op/h 360 Electrical endurance(ARI 780/790) cycle 200,000 Mechanical life (ARI 780/790) cycle 500,000 4 Pole Characteristics Full Load Amps(FLA)/ Rated operation Amps(AC-8a) Poles 25 1 32 1 40 1 40 1 25 2 32 2 40 2 25 2 3 32 2 3 40 2 3 50 2 3 63 2 3 75 2 3 90 2 3 Voltage 240/277 480 600 240/277 480 600 240/277 480 600 240/277 480 600 240/277 480 600 240/277 480 600 240/277 480 600 240/277 480 600 240/277 480 600 240/277 480 600 240/277 480 600 240/277 480 600 240 480 600 240 480 600 Locked Rotor Amps (LRA) 150 180 150 120 240 240 200 150 125 100 180 150 120 240 200 160 150 125 100 180 150 120 240 200 160 300 250 200 360 300 240 450 375 300 540 450 360 Resistive Amps Rating (RES) Conventional free air thermal current(Ith) 35 Maximum Horsepower(HP) Catalog Number Voltage Single Phase Three Phase 32 240/277 2 - XMC0-257* XMC0-251* 40 40 240/277 2 - XMC0-327* XMC0-321* 50 50 240/277 3 - XMC0-407* XMC0-401 50 50 240/277 3 - XMC0-407*H XMC0-401*H 35 32 240/277 3 - XMC0-252* 40 40 240/277 3 - XMC0-322* 50 50 240/277 3 - XMC0-402* 35 32 40 40 50 50 63 63 75 80 94 94 120 120 240/277 480 600 240/277 480 600 240/277 480 600 240/277 480 600 240/277 480 600 240 480 600 240 480 600 3 3 5 5 7.5 15 15 - 5 7.5 10 7.5 10 15 10 15 20 15 20 25 20 25 30 25 40 40 30 50 50 XMC0-253A* XMC0-253* XMC0-323A* XMC0-323* XMC0-403A* XMC0-403* XMC0-503A* XMC0-503* XMC0-633A* XMC0-633* XMC0-753A* XMC0-753* XMC0-903A* XMC0-903* Note: All the models also could be marked or used for the actual applications which have less contact ratings than the certificated ratings. The rating can be Voltage, FLA, LRA or RES. 5 Auxiliary contacts block characteristics Conventional thermal current (A) 10 Rated insulation voltage (V) 690 Rated operational current (A) A600(AC-15) 230/380V 3/1.9 N600(DC-13) 110/230V 2.2/1.1 Microswitch Blocks characteristics 10A or 11A, 1/3 HP, 125 or 250 VAC 1/2A, 125 VDC; 1/4A, 250 VDC 4A 120 VAC on Lamp Load Contact Rating(SPDT) Coil characteristics @ 25℃(Cold state) Part number Inrushed VA Sealed VA Sealed Watts Voltage 60Hz 50Hz 60Hz 50Hz 60Hz Pick-up Drop-out XMC0-□1/7 40 55 7.5 10 3 XMC0-□2 45 55 8 10.5 3.5 XMC0-□3/3A 80 90 12 16 5 ≤0.8Us ≥0.2Us XMC0-503/633 145 160 17.6 23 7 XMC0-753/903 300 325 35 46 12 Notes:Us=24VAC 50/60Hz(“E“coil) or 120VAC 50/60Hz(“F“coil) or 220VAC/50Hz, 240VAC/60Hz(“I“coil) or 277VAC/60Hz(“L“ coil) or 415VAC/50Hz, 480VAC/60Hz(“N“coil). Inrushed VA and Sealed VA test at Us. Dimensions & Wiring diagram 6 7 8 9 10 11 12 13 14 Remarks 1) Torque for Screws 25 lb-in/Lugs 25 lb-in for 25-40FLA types; Torque for Screws 45 lb-in /Lugs 50 lb-in for 50-63FLA types; Torque for Screws 50 lb-in /Lugs 60 lb-in for 75-90FLA types; Torque for Screws 8 lb-in for Auxiliary Contact Blocks; Torque for Coil Screws 8 lb-in for 3-pole 25-40FLA types and 12 lb-in for 50-90FLA types; 2) For QC wiring, the female connector should meet IEC60760, necessary to ensure the reliability of connection between female connectors and QC terminals. 3) If the actual condition differs from this specification, please contact us for further discussion. 15