Datasheet

30C50
definite purpose contactor
• 30C 50FLA Definite Purpose Contactor
• Robust 2 & 3 Pole Contactor
• Arc Covers as standard
• Industry Standard Mounting
• RoHS Compliant
• UL File No: E61703
Contact Data
Arrangements:
Table 1
2 Form X (2PST-NO-DM)
3 Form X (3PST-NO-DM)
Material:
AgCdO, AgSnOInO
Model No
30C50-1022
30C50-1023
Full Load
Amps (FLA)
Poles
50
Line Voltage
(VAC)
Locked Rotor
Amps (LRA)
120
300
240/277
300
480
250
600
200
120
300
240/277
300
480
250
600
200
2
50
3
Max. HP
Resistive
Amps
65
65
Voltage
1 Phase
120
3
240
10
120
3
240
10
3 Phase
15
15
480
25
600
25
FLA rating tested for 6000 cycles of endurance at 240/480/600VAC per UL508.
Resistive Heat rating tested for 250,000 cycles at 277VAC.
LRA rating tested for 6000 cycles of Locked Rotor endurance per UL508.
Coil Data
Table 2
Voltage: 24-277VAC 50/60Hz. See coil data below. (480VAC available but not UL approved)
Insulation Class: UL Class B (130°C)
Coil
Voltage
Code
5024
Page 1 of 3
Coil Operating Voltage (VAC)
Minimum Inrush
Nominal Coil Power
Rated
Voltage
50/60Hz
Coil
Resistance
(Ohms)
Must
Release
Must
Operate
Max
Voltage
VA @ 50Hz
VA @ 60Hz
VA @ 50Hz
VA @ 60Hz
24
2.4
6
18
30
138
130
18
13
5120
120
45
20
88
132
138
130
18
13
5230
208/240
180
40
177
264
138
130
18
13
5277
277
280
65
220
300
138
130
18
13
5480
480
852
150
384
520
138
130
18
13
Ref: 30C50 101711JHM
www.aecsensors.com
Sales Department Tel: (888) 847-6552
30C50
definite purpose contactor
General Specifications
Table 2
Initial Operate Time
mS
30
Terminations
Release Time
mS
15 (typical)
Bounce Time
mS
≤ 10
Coil Terminals
Arc Cover
Standard
Power Terminals
Insulation System
UL Class B 130°C
Initial Dielectric Strength
0.250” QC + #6-32 screw
(dual 0.250” QC optional) per terminal
screw
box lug
between contacts and coil
VAC 2200
between poles
VAC 2200 (includes shunt)
between open contacts
VAC 2200
Temperature Range
°C
Unit Weight (approx.)
3 pole
-40 ... +65
#1/4-20 Screw (with or without sems plate)
14-2 AWG
Recommended Tightening
Torque
#1/4-20
40 in.lbf (4.53 Nm)
box lug
50 in.lbf (5.65 Nm)
Wire size
#1/4-20
16-8AWG*
box lug
14-2AWG
22.4 oz
* Must use ring terminals
Ordering Codes
Type
3
0
C
Contact
material
5
0
-
1
0
Contact
arrangement
2
Cover protection and
terminations
-
1
Coil code
-
-
Contact Ratings
50
-
50 FLA
see Table 1
Contact Material
10
-
AgCdO (standard)
70
-
AgSnOInO
T
Terminals
Contact number & arrangement
22
-
DPST-NO
23
-
3PST-NO
L
Terminals
Cover protection category
1
-
IP00, no overall cover
Termination Codes (see drawings for full specifications)
1
-
#10-32 combination philips screw with quad QC blades
2
-
Same as 1 with sems screw and pressure plate
3
-
#14-4AWG box lug with quad QC blades (box lug with quick connect)
4
-
#14-4AWG box lug with dual QC blades (box lug with quick connect) (standard for 40FLA)
5
-
#10-32 combination phillips screw with dual QC blades (standard for 20-30FLA)
6
-
#14-2AWG box lug with QC blades (standard for 50-60FLA)
7
-
#14-1AWG box lug with QC blades (standard for 75-150FLA)
Reserved for Customer Specific Requirements
001
-
Dual 0.25” QC blades for coil terminations
002
-
999 - optional customer specific number
Page 2 of 3 Ref: 30C50 101711JHM
www.aecsensors.com
Sales Department Tel: (888) 847-6552
Special options
30C50
definite purpose contactor
Fig. 1
Overall Dimensions
.450
.362
2.033
1.467
3.140
3.231
.215
2.187
2.75
Dimensions in inches
2 Pole same as 3 pole minus centre terminals
Power Terminations
Termination Codes: 1 & 5
Standard for 20-30FLA only
#10-32 combination phillips/slotted
and 5/16 hex head screw with #12 washer
Termination Code: 6
Standard for 50 & 60FLA
Box Lug
14-2 AWG (Cu/Al)
Termination Code: 2
Optional for 20-40FLA only.
#10-32 sems screw with pressure plate
Termination Code: 7
Standard for 75 & 90FLA
Box Lug
14-1 AWG (Cu/Al)
Termination Codes: 3 & 4
Standard for 40FLA only
Box Lug
14-4 AWG (Cu/Al)
0.25 6
Dimension in inches
American Electronic Components Inc,. 1100 Lafayette St., Elkhart, IN 46516
Toll Free: (888) 847-6552, Tel: (574) - 295-6330
www.aecsensors.com
Specifications and availability are liable to change without notice.
Page 3 of 3 Ref: 30C50 101711JHM
www.aecsensors.com
Sales Department Tel: (888) 847-6552
0.28 6
0.39 5