Technical Data RDWN

RDWN
Differential pressure switch for variable
static pressure
Main Features
„„
Excellent repeatability
„„
Dead band adjustment for regulation
„„
Fix dead band for control and alarm
„„
Static pressure max. 20 bar
„„
No influence of the static pressure on the setpoint
Applications
„„Power generation safety equipment
„„Pressurized chambers control
„„Liquid level control
Technical Data
Pressure range
10 ... 200 mbar to 0 ... 2000 mbar
Temperature
Process : Ambient : Storage : -15 ... +150°C
-25 ... +55°C
-40 ... +70°C
Repeatability
± 1% F.S. @ constant pressure cycle
CE conformity
Low Voltage Directive LVD 2006/95/EC
Pressure Equipment Directive PED 97/23/EC
IP 66 (EN 60529)
Protection rating
Electrical
connection
Electrical function
Terminal block with plastic cable gland :
- cable Ø 7 to 10.5 mm
Adjustment
2 external adjustment screws on top of the case
for set point and dead band.
The adjustment is not influenced by changes of
the static pressure.
See ordering code details in page 5
Process Connection Stainless steel 1.4404 (316L)
Sensing element
Scale
Housing
Flanges : Stainless steel 1.4404 (316L)
Diaphragm : Viton®
Internal. Accuracy on reading ± 5% F.S.
Case
Zamak blue painted
Captive stainless steel screws
Zamak black
Mounting
Wall mounting braket
Ground connection
Via internal terminal block
Code SETP
Oxygen application
Code 0765
Mounting on 2" pipe
Code 0407
Stainless steel tag plate and wire
Code 9941
Lead seal of the adjustment screws
Code 8990
Mobile plug for stainless steel connector (Souriau)
Code 2249
Electrical connection : stainless steel connector (Souriau)
Code 2298
2015-04-17
Customer specific set point adjustment
Design and specifications subject to change without notice
Options
www.baumer.com
Data sheet A32.40
Page 1 / 5
RDWN
Differential pressure switch for variable
static pressure
Principle
∆P
A flexible sensing element actuates a microswitch by means of a
lever. The set point is adjusted by means of a compressible spring
installed in opposition.
NC
NC
NC
C
C
C
NO
NO
NO
Set point and reset point must be between 10% and 90% of the selected scale.
Standard factory adjustment
Setpoint at 50% of the scale on falling pressure
Customer speciffic factory adjustment (option SETP)
The following specifications have to be given with the order:
• Setpoint value
• Adjustment on falling or raising pressure
• Dead band value when using an adjustable dead band switch
NC
C
NC
NC
C
C
NO
NO
NO
Electrical connections
2 SPDT
1 SPDT
NC
Blue
COM
Red
NO
White
NC
Blue
COM
Red
NO
Yellow / green
NC
COM
NO
White
Blue
Red
White
2015-04-17
Design and specifications subject to change without notice
Yellow / green
www.baumer.com
Data sheet A32.40
Page 2 / 5
RDWN
Differential pressure switch for variable
static pressure
Micro switches characteristics
Switch code
Type
6 Vdc
N (T)
A (B)
M (K)
C (W)
E (F)
H
D (V)
J
Tropicalized
Standard
Gold contact
Hermetic
Ultra
sensitive
Manual reset
Ultra
sensitive
Hermetic
Manual reset
10... 50 mA
5 mA ... 4 A
0.1... 8A
0.4... 10 A
0.4... 1A
N/A
0.4... N/A
12 Vdc
0.1... 8A
0.4... 10 A
10... 50 mA
5 mA ... 4 A
0.4... 1A
0.4... 4A
24 Vdc
0.1... 8A
0.4... 6A
10... 50 mA
5 mA ... 4 A
0.4... 1A
0.1... 8A
0.4... 4A
0.1... 8A
30 Vdc
0.1... 8A
0.4... 6A
10... 10 mA
5 mA ... 3 A
0.4... 1A
0.1... 8A
0.4... 2A
0.1... 8A
48 Vdc
0.1... 8A
0.4... 6A
10... 50 mA
5 mA ... 3 A
0.1... 8A
0.1... 8A
N/A
N/A
4A
N/A
N/A
110 Vdc
N/A
0.1... 0.5 A
10... 50 mA
5 mA ... 1 A
N/A
N/A
N/A
N/A
220 Vdc
N/A
0.1... 0.25 A
10... 50 mA
5 mA ... 0.5 A
N/A
N/A
N/A
N/A
115 Vac
0.1... 10 A
0.4... 10 A
10... 50 mA
50 mA ... 3 A
10 A
0.1... 10 A
N/A
0.1... 10 A
250 Vac
0.1... 5A
0.2... 10 A
10... 50 mA
50 mA ... 2.5 A
0.2 ... 10 A
0.1... 5A
N/A
0.1... 5A
2000 V
1500 V
2000 V
Dielectric rigidity
between contacts
and ground
2000 V
2000 V
0.4... 2000 V
1000 V
2000 V
Adjustable ranges
Scale
mbar
Max
ΔP
mbar
Max P
Static
Micro-switch dead band 1)
Adjustable dead band
Code
N (T*)
A (B*)
10%
bar
M (K*)
90%
Fixed dead band
C(W*)
10%
E(F*)
90%
H
10%
90%
10%
D (V*)
J
90%
mbar
10 ... 200
200
20
156
8 - 80
10.5 - 80
35 - 80
45 - 80
2.5
3.4
10
13
10 ... 400
400
20
157
15 - 150
20 - 150
40 - 150
50 - 150
4.5
6
18
24
10 ... 1000
1000
20
158
18 - 150
22 - 150
45 - 150
60 - 150
5
7
22
26.5
10 ... 700
700
20
161**
30 - 250
45 - 250
130 - 450
150 - 450
13
15
36
54
10 ... 1500
1500
20
162**
30 - 300
45 - 300
130 - 450
150 - 450
13
15
36
54
10 ... 2000
2000
20
163**
45 - 300
90 - 300
180 - 450
300 - 450
18
25
54
108
(*) For version with 2 microswitches lower values of the dead band must be multiplied x 1.5
(**) G1/4 female only
The value of the dead band is depending on the value of the set point.
This table contains the dead band values for set point adjustment at 10% and 90% of the selected scale. For adjustable dead band the lower value corresponds to
the dead band spring totally released and the higher corresponds to the dead band spring fully tensed. For other set points the dead band value can be calculated by
linear interpolation between the values at 10% and 90%.
2015-04-17
Design and specifications subject to change without notice
1)
www.baumer.com
Data sheet A32.40
Page 3 / 5
RDWN
Differential pressure switch for variable
static pressure
Dimensions (mm)
125
76.5
=
144
139
=
58
130
5
64
100
45°
Pressure range codes : 156-157-158
Weight : 6.6 kg
Pressure range codes : 161-162-163
Weight : 7 kg
130
144
76,5
28,5
G 1/2 (M)
LP
HP
HP
109
LP
Ø100
2015-04-17
Design and specifications subject to change without notice
48
29,5
100
G 1/2 (M)
2 holes G 1/4 (F)
Hex 24
Ø 148
www.baumer.com
Data sheet A32.40
Page 4 / 5
RDWN
Differential pressure switch for variable
static pressure
Ordering details RDWN
RD WN
Model
Differential pressure switch for variable static pressure
Approvals
Standard version without ATEX approval
Type of micro switches
1 SPDT standard changeover switch
2 SPDT standard changeover switch
1 SPDT hermetically changeover switch
2 SPDT hermetically changeover switch
1 SPDT ultra sensitive changeover switch
2 SPDT ultra sensitive changeover switch
1 SPDT hermetically, ultra sensitive changeover switch
2 SPDT hermetically, ultra sensitive changeover switch
1 SPDT gold contact changeover switch
2 SPDT gold contact changeover switch
1 SPDT tropicalized changeover switch
2 SPDT tropicalized changeover switch
1 SPDT changeover switch, manual reset, opening on raising pressure
1 SPDT changeover switch, manual reset, opening on falling pressure
Pneumatic changeover contact, NO
Pneumatic changeover contact, NC
Type
Standard
Process connection
G 1/4 female (only pressure ranges 161, 162, 163)
G 1/2 male (standard)
1/2 NPT male
1/4 NPT female
Pressure range (mbar)
Pressure range (kPa)
10 ...
200
1
...
20
10 ...
400
1
...
40
10 ... 1000
1 ... 100
10 ...
700
1 ...
70
10 ... 1500
1 ... 150
10 ... 2000
1 ... 200
Options to be added behind the / (see example below)
A
–
.
xxx
/
RD
WN
Deadband
Adjustable
Adjustable
Adjustable
Adjustable
Fix
Fix
Fix
Fix
Adjustable
Adjustable
Adjustable
Adjustable
Fix
Fix
–
A
B
C
W
E
F
D
V
M
K
N
T
H
J
Z
Y
A
H
3
6
8
.
156
157
158
161
162
163
Process connection G1/4 female
Process connection G1/4 female
Process connection G1/4 female
Ordering example with options
RD
WN
–
A
A
3
.
156
/
0407
_
9941
Differential pressure switch for variable static pressure
Without ATEX approval
Design and specifications subject to change without notice
1 SPDT standard changeover switch
Standard type
Process connection G 1/2 male
Pressure range 10 ... 200 mbar
Option : Mounting on 2" pipe
2015-04-17
Option : Stainless steel tag plate and wire
www.baumer.com
Data sheet A32.40
Page 5 / 5