Technical Data RPPN8

RPPN6 - RPPN8
Industrial pressure switch with high overpressure
resistance
Main Features
„„
Excellent repeatability
„„
Dead band adjustment for regulation
„„
Fix dead band for control and alarm
„„
Overpressure up to 100 bar
Applications
„„
Energy safety equipment
„„
Power generation safety equipment
„„
Pressurized chambers control
„„
Liquid level control
Technical Data
Pressure range
-1 ... 2.5 bar to 0.2 ... 4 bar
Case
Black Zamak
Temperature
Process: -50 ... +200 °C
Ambient: -25 ... +55 °C
Storage: -40 ... +70 °C
Mounting
Wall mounting braket
Ground connection
Via internal terminal block
Terminal block with plastic cable gland for
Ø 7 to 10.5 mm
2 external adjustment screws on top of the case
for set point and dead band
Repeatability
± 1% F.S. / constant pressure cycle
CE conformity
Low Voltage Directive LVD 2006/95/EC
Electrical
connection
Electrical function
Protection rating
IP 66 (EN 60529)
Adjustment
Process Connection Stainless steel 1.4404 (316L)
Sensing element
See ordering code details in page 5
Pressure range code 201 (RPPN6)
Diaphragm: Perbunan®
Flanges: Steel, galvanized, bichromate finish
Pressure range code 204 to 210 (RPPN8)
Diaphragm: Stainless steel 1.4404 (AISI 316L)
Fitting: Stainless steel 1.4404 (AISI 316L)
Scale
Internal. Accuracy on reading ± 5% F.S.
Cover
Zamak blue painted
Captive stainless steel screws
Code SETP
Oxygen application
Code 0765
Mounting on 2" pipe
Code 0407
Electrical connection: stainless steel connector (Souriau)
Code 2298
Mobile plug for stainless steel connector (Souriau)
Code 2249
Stainless steel tag plate and wire
Code 9941
Lead seal of the adjustment screws
Code 8990
2015-11-12
Customer specific set point adjustment
Design and specifications subject to change without notice
Options
www.baumer.com
Data sheet A32.08
Page 1 / 5
RPPN6 - RPPN8
Industrial pressure switch with high overpressure
resistance
Principle
A flexible sensing element actuates a microswitch by means of a
lever. The set point is adjusted by means of a compressible spring
installed in opposition.
NC
NC
NC
C
C
C
NO
NO
NO
Set point and reset point must be between 10% and 90% of the
selected scale.
Standard factory adjustment
Setpoint at 50% of the scale on falling pressure
NC
C
NC
NC
C
C
NO
Customer specific factory adjustment (option SETP)
The following specifications have to be given with the order:
• Setpoint value
• Adjustment on falling or raising pressure
• Dead band value (as needed) when using an adjustable dead band
switch
NO
NO
Electrical connections
2 SPDT
1 SPDT
NC
Blue
COM
Red
NO
White
NC
Blue
COM
Red
NO
Yellow / green
NC
COM
NO
White
Blue
Red
White
2015-11-12
Design and specifications subject to change without notice
Yellow / green
www.baumer.com
Data sheet A32.08
Page 2 / 5
RPPN6 - RPPN8
Industrial pressure switch with high overpressure
resistance
Micro switches characteristics
Switch code
A (B)
M (K)
C (W)
E (F)
H
D (V)
J
Type
Standard
Gold contact
Hermetic
Ultra sensitive
Manual reset
Ultra sensitive
Hermetic
Manual reset
6 Vdc
0.4 ... 10 A
10 ... 50 mA
5 mA ... 4 A
0.4 ... 1 A
N/A
0.4 ... 4 A
N/A
12 Vdc
0.4 ... 10 A
10 ... 50 mA
5 mA ... 4 A
0.4 ... 1 A
N/A
0.4 ... 4 A
N/A
24 Vdc
0.4 ... 6 A
10 ... 50 mA
5 mA ... 4 A
0.4 ... 1 A
0.1 ... 8 A
0.4 ... 4 A
0.1 ... 8 A
30 Vdc
0.4 ... 6 A
10 ... 10 mA
5 mA ... 3 A
0.4 ... 1 A
0.1 ... 8 A
0.4 ... 2 A
0.1 ... 8 A
48 Vdc
0.4 ... 6 A
10 ... 50 mA
5 mA ... 3 A
N/A
0.1 ... 8 A
N/A
0.1 ... 8 A
110 Vdc
0.1 ... 0.5 A
10 ... 50 mA
5 mA ... 1 A
N/A
N/A
N/A
N/A
220 Vdc
0.1 ... 0.25 A
10 ... 50 mA
5 mA ... 0.5 A
N/A
N/A
N/A
N/A
115 Vac
0.4 ... 10 A
10 ... 50 mA
50 mA ... 3 A
0.4 ... 10 A
0.1 ... 10 A
N/A
0.1 ... 10 A
250 Vac
0.2 ... 10 A
10 ... 10 mA
50 mA ... 2.5 A
0.2 ... 10 A
0.1 ... 5 A
N/A
0.1 ... 5 A
2000 V
2000 V
1500 V
2000 V
2000 V
1000 V
2000 V
Dielectric rigidity between contacts
and ground
Adjustable ranges
Scale
-1
P. Max
accidental
Micro-switch dead band 1)
Adjustable dead band
Code
A (B*)
10%
bar
bar
... 2.5
80
201 2)
M (K*)
Fixed dead band
C (W*)
90%
10%
E (F*)
90%
10%
bar
0.25 - 2
0.3 - 2
H
90%
10%
mbar
0.8 - 2
1 - 2.5
65
D (V*)
J
90%
bar
75
0.3
0.35
0.5 ... 10
50
204
0.18 - 3
0.25 - 3
0.63 - 3
0.80 - 3
45
62
0.25
0.3
3.5 ... 25
100
205 3)
0.45 - 10
0.9 - 10
1.5 - 10
3.1 - 10
150
200
0.55
1.1
5
... 50
100
206 3)
1 - 10
2 - 10
3.5 - 10
7 - 10
200
300
1.5
2.5
0.2 ... 4
50
210
0.1 - 3
0.18 - 3
0.35 - 3
0.63 - 3
40
50
0.15
0.25
3)
3)
(*) When using 2 microswitches deadband lower values should be x1.5
The value of the deadband is depending on the value of the set point.
This table contains the deadband values for set point adjustment at 10% and 90% of the selected scale. For adjustable deadband the lower value corresponds to
the deadband spring totally released and the higher corresponds to the deadband spring fully tensed. For other set points the deadband value can be calculated by
linear interpolation between the values at 10% and 90%.
1)
2)
For RPPN6 only.
For RPPN8 only.
2015-11-12
Design and specifications subject to change without notice
3)
www.baumer.com
Data sheet A32.08
Page 3 / 5
RPPN6 - RPPN8
Industrial pressure switch with high overpressure
resistance
Dimensions (mm)
76.5
125
=
144
139
=
5
64
100
58
130
45°
Pressure range code: 204 - 205 - 206 - 210
Weight: 2.4 kg
50
63
Pressure range code: 201
Weight: 2.4 kg
26 flats
plats
G1/2 male
1/4NPT female
G1/2 male
Ø44
2015-11-12
Design and specifications subject to change without notice
Ø60
plats
24 flats
www.baumer.com
Data sheet A32.08
Page 4 / 5
RPPN6 - RPPN8
Industrial pressure switch with high overpressure
resistance
Ordering details RPPN6 - RPPN8
RP
Model
Industrial pressure switch
Approvals
Standard version without ATEX approval
Sensing element
Diaphragm (Perbunan ®, code 201)
Diaphragm (Stainless steel, range 204 to 210)
Type of micro switches
1 SPDT standard changeover switch
2 SPDT standard changeover switch
1 SPDT hermetically changeover switch
2 SPDT hermetically changeover switch
1 SPDT ultra sensitive changeover switch
2 SPDT ultra sensitive changeover switch
1 SPDT hermetically, ultra sensitive changeover switch
2 SPDT hermetically, ultra sensitive changeover switch
1 SPDT gold contact changeover switch
2 SPDT gold contact changeover switch
1 SPDT changeover switch, manual reset, opening on raising pressure
1 SPDT changeover switch, manual reset, opening on falling pressure
Pneumatic changeover contact, NO
Pneumatic changeover contact, NC
Process connection
G 1/2 male (standard)
1/2 NPT male
1/4 NPT female
PN
.
–
xxx
/
RP
PN
–
6
8
Deadband
Adjustable
Adjustable
Adjustable
Adjustable
Fix
Fix
Fix
Fix
Adjustable
Adjustable
Fix
Fix
A
B
C
W
E
F
D
V
M
K
H
J
Z
Y
3
6
8
.
Pressure range (bar)
Pressure range (kPa)
-1
... 2.5 1)
-100 ... 250 1)
2)
0.5 ... 10 2)
50 ...1000
3.5 ... 25 2)
350 ...2500 2)
5
... 50 2)
500 ...5000 2)
0.2 ... 4 2)
20 ... 4
00 2)
Options to be added behind the / (see example below)
1) RPPN6 only
2) RPPN8 only
201
204
205
206
210
/
Ordering example with options
RP
PN
–
6
A
3
.
201
/
0407
_
9941
Industrial pressure switch
Without ATEX approval
Diaphragm Perbunan®
Design and specifications subject to change without notice
1 SPDT standard changeover switch
Process connection G 1/2 male
Pressure range -1 ... 2.5 bar
Option: Mounting on 2" pipe
2015-11-12
Option: Stainless steel tag plate and wire
www.baumer.com
Data sheet A32.08
Page 5 / 5