RPPE3 - RPPE7 RPPE3

RPPE3 - RPPE7
Industrial pressure switch explosion proof
Main Features
„„
Excellent repeatability
„„
Fix dead band for control and alarm
„„
Dead band adjustment for regulation
„„
Explosion proof Hazardous areas 1, 2, 21, 22
Applications
„„Power generation safety equipment
„„Presurized chambers control
„„Liquid level control
Technical Data
Pressure range
-50 mbar ... 0 to 60 ... 600 bar
Housing
Temperatures
Pressure range codes 101 to 153
Medium : -15 ... +150°C
Ambient : -20 ... + 70°C (T5)
-20 ... + 60°C (T6)
Storage : -40 ... + 70°C
Type RA80, explosion proof, flameproof
Alumunium epoxy painted.
Captive stainless steel screws
Mounting
3 back lugs for wall mounting
Ground connection
Via internal terminal block
Electrical
connection
Electrical function
Terminal block with metallic cable gland for
Ø 7 to 12 mm standard
Adjustment
2 external adjustment screws on top of the case
for set point and dead band
Type examination certificate
LCIE 03 ATEX 6231X (Type RA80)
EN 60079-0: 2012 (internal conformity analysis)
EN 60079-1: 2007
EN 60079-31: 2009
Marking
0081
II 2 G D
Ex d IIC T6 or T5 Gb
Ex t IIIC IIC T80°C or T95°C Db IP6X
T° ambient
Repeatability
± 1% F.S. @ constant pressure cycle
CE conformity
Low Voltage Directive LVD 2006/95/EC
Pressure Equipment Directive PED 97/23/EC
ATEX Directive 94/9/EC
Protection rating
IP 66 (EN 60529)
Process Connection Stainless steel 1.4404 (316L)
Sensing element
Pressure range codes 101 to 153
Flanges :Stainless steel 1.4404 (316L)
Diaphragm :Viton®
Pressure range codes 200 to 209
Bellow :Stainless steel 1.4404 or
1.4432 (316L)
Pressure range codes 600 to 602
Piston :Nickel plated steel
Scale
ATEX
See ordering code details in page 5
-20°C to +60°C (T6 or T80°C) or
-20°C to +70°C (T5 or T95°C)
Design and specifications subject to change without notice
Pressure range codes 200 to 602
Medium : -50 ... +200°C
Ambient : -25 ... + 60°C (T6)
Storage : -40 ... + 70°C
Internal. Accuracy on reading ± 5% FS
Options
Code SETP
Oxygen application
Code 0765
Mounting on 2" pipe
Code 0407
Stainless steel tag plate and wire
Code 9941
Lead seal of the adjustment screws
Code 8990
2015-05-22
Customer specific set point adjustment
www.baumer.com
Data sheet A32.06
Page 1 / 5
RPPE3 - RPPE7
Industrial pressure switch explosion proof
Principle
A flexible sensing element actuates a microswitch by means of a
lever. The set point is adjusted by means of a compressible spring
installed in opposition.
NC
NC
C
C
NC
C
NO
NO
NO
Set point and reset point must be between 10% and 90% of the
selected scale.
Standard factory adjustment
Setpoint at 50% of the scale on falling pressure
NC
C
C
C
NO
NC
NC
Customer speciffic factory adjustment (option SETP)
The following specifications have to be given with the order:
• Setpoint value
• Adjustment on falling or raising pressure
• Deadband value when using an adjustable dead band switch
NO
NO
Electrical connections
2 SPDT
1 SPDT
NC
COM
NO
Blue
Red
White
NC
Blue
COM
Red
NO
White
NC
Blue
COM
Red
NO
White
Yellow / green
Hazardous areas : 1, 2, 21, 22
-20°C ≤ Ta ≤ +70°C
Dust IP6x
Gases
T° surface
Class
Ta = 60°C
80°C
T6
Ta = 70°C
95°C
T5
Important : Maximum power dissipation in the case
must not exceed 5 W
2015-05-22
All necessary measures must be taken by the user, to avoid the calorific transfer from the fluid to the apparatus head increasing the head's
temperature to such that it reaches the self-ignition temperature of the gas in which it is used.
Design and specifications subject to change without notice
Yellow / green
www.baumer.com
Data sheet A32.06
Page 2 / 5
RPPE3 - RPPE7
Industrial pressure switch explosion proof
Micro switches characteristics
Switch code
N (T)
A (B)
M (K)
C (W)
E (F)
D (V)
Type
Tropicalized
Standard
Gold contact
Hermetic
Ultra sensitive
Ultra sensitive
Hermetic
6 Vdc
0.1 ... 8 A
0.4 ... 10 A
10 ... 50 mA
5 mA ... 4 A
0.4 ... 1 A
0.4 ... 4 A
12 Vdc
0.1 ... 8 A
0.4 ... 10 A
10 ... 50 mA
5 mA ... 4 A
0.4 ... 1 A
0.4 ... 4 A
24 Vdc
0.1 ... 8 A
0.4 ... 6 A
10 ... 50 mA
5 mA ... 4 A
0.4 ... 1 A
0.4 ... 4 A
30 Vdc
0.1 ... 8 A
0.4 ... 6 A
10 ... 50 mA
5 mA ... 3 A
0.4 ... 1 A
0.4 ... 2 A
48 Vdc
0.1 ... 8 A
0.4 ... 6 A
10 ... 50 mA
5 mA ... 3 A
N/A
N/A
110 Vdc
N/A
0.1 ... 0.5 A
10 ... 50 mA
5 mA ... 1 A
N/A
N/A
220 Vdc
N/A
0.1 ... 0.25 A
10 ... 50 mA
5 mA ... 0.5 A
N/A
N/A
115 Vac
0.1 ... 10 A
0.4 ... 10 A
10 ... 50 mA
50 mA ... 3 A
0.4 ... 10 A
N/A
250 Vac
0.1 ... 5 A
0.2 ... 10 A
10 ... 10 mA
50 mA ... 2.5 A
0.2 ... 10 A
N/A
2000 V
2000 V
2000 V
1500 V
2000 V
1000 V
Dielectric rigidity between contacts and ground
Adjustable ranges
Scale
mbar
Micro-switch dead band 1)
Adjustable dead band
Code
101
-2
... 10
0.15
-5
... 50
0.15
-8
... 100
90%
Fixed dead band
C (W*)
10%
E (F*)
90%
D (V*)
10%
90%
10%
90%
11.3 - 37
0.75
0.75
3.8
4.5
3 - 37
3.8 - 37
102
1.5 - 8
1.8 - 8
6.8 - 8
6.8 - 8
0.45
0.45
2.3
2.3
103
1.8 - 22
3 - 22
7.5 - 22
11 - 22
0.6
0.6
2.3
3.8
0.15
104
2.3 - 37
3 - 37
7.5 - 37
15 - 37
0.75
0.75
3
3.8
0
1
151
9 - 120
12 - 120
23 - 120
23 - 120
3
4.5
11.3
15
... 200
1
152
9 - 120
12 - 120
23 - 120
23 - 120
3
4.5
11.3
15
1
153
23 - 220
30 - 220
45 - 220
53 - 220
6
9
27
37
bar
Code
1.5
200
37 - 375
53 - 375
120 - 375
142 - 375
7.5
9
45
63
120 - 1800
150 - 1800
225 - 1800
300 - 1800
33
37
144
180
-200... ... 400
bar
-1
M (K*)
mbar
0.15
0
A (B*)
10%
bar
0
-50 ... 0
N (T*)
... 0
9.8 - 37
mbar
-1
... 2.5
7
201
0
... 0.2
1.5
202
22 - 150
30 - 150
90 - 150
97 - 100
6
7.5
27
36
1
1.5
203
30 - 600
37 - 600
120 - 600
142 - 600
6
7.5
36
45
0.5 ... 10
30
204
300 - 4500
375 - 4500
975 - 4500
1275 - 4500
67
75
360
450
3.5 ... 25
30
205
900 - 7500
1800 - 7500
1125 - 7500
1950 - 7500
90
150
1080
2160
bar
bar
Code
0.05... bar
5
... 50
65
206
1.5 - 15
3 - 15
3.7 - 15
4.5 - 15
0.225
0.3
2.2
3.7
5
... 100
220
207
3.7 - 22
4.5 - 22
8.2 - 22
9.7 - 22
1.050
1.350
4.5
5.2
220
208
3.7 - 22
5.2 - 22
8.2 - 22
9.7 - 22
1.050
1.500
4.5
6.7
20 ... 150
... 3.5
30
209
0.22 - 2.2
0.3 - 2.2
0.97 - 2.2
1.27 - 2.2
0.067
0.075
0.3
0.37
25 ... 175
800
600
30 - 120
45 - 120
45 - 120
47 - 120
22
22
36
54
30 ... 350
800
601
30 - 150
45 - 150
45 - 150
47 - 150
24
24
36
54
60 ... 600
800
602
30 - 180
45 - 180
45 - 180
47 - 180
24
24
36
54
-1
(*) When using 2 microswitches deadband lower values should be x1.5
The value of the deadband is depending on the value of the set point.
This table contains the deadband values for set point adjustment at 10% and 90% of the selected scale. For adjustable deadband the lower value corresponds to
the deadband spring totally released and the higher corresponds to the deadband spring fully tensed . For other set points the deadband value can be calculated
by linear interpolation between the values at 10% and 90%.
2015-05-22
1)
Design and specifications subject to change without notice
P. Max
accidental
www.baumer.com
Data sheet A32.06
Page 3 / 5
RPPE3 - RPPE7
Industrial pressure switch explosion proof
Dimensions (mm)
Set point adjustment
Differential adjustment
56
(3x) Ø 9 on Ø 222
86
20
Ø 194
12
0°
Weight of the
housing : 4.4 kg
120°
116
RA
139
EE
x d II C T
0°
6
12
Cable gland
not mounted
121
52
Ø 146
Pressure range code : 200 - 202 - 203
Weight : 2.5 kg
68
Pressure range code : 151 - 152 - 153
Weight : 2.8 kg
Pressure range code : 101 - 102 - 103 - 104
Weight : 3 kg
Ø 90
Hex 24
Hex 24
G 1/2(M)
1/2 NPT(M)
G 1/2(M)
Ø 218
Pressure range code : 204 - 205 - 206 - 207 - 208 209 - 600 - 601 - 602
Weight : 2 kg
Ø 65
Hex 24
Design and specifications subject to change without notice
68
Pressure range code : 201
Weight : 2.4 kg
1/2 NPT(M)
2015-05-22
1/2 NPT(M)
www.baumer.com
Data sheet A32.06
Page 4 / 5
RPPE3 - RPPE7
Industrial pressure switch explosion proof
Ordering details RPPE3 - RPPE7
RP
Model
Industrial pressure switch
Approvals
Explosion proof
PE
xxx
/
RP
PE
Sensing element
Diaphragm (Viton ®, range 101 to 153)
Bellow (stainless steel, range 200 to 209) or Piston (nickel plated steel, range 600 to 602)
Type of micro switches
Deadband
1 SPDT standard changeover switch
Adjustable
2 SPDT standard changeover switch
Adjustable
1 SPDT hermetically changeover switch
Adjustable
2 SPDT hermetically changeover switch
Adjustable
Fix
1 SPDT ultra sensitive changeover switch
2 SPDT ultra sensitive changeover switch
Fix
1 SPDT hermetically, ultra sensitive changeover switch
Fix
2 SPDT hermetically, ultra sensitive changeover switch
Fix
1 SPDT gold contact changeover switch
Adjustable
2 SPDT gold contact changeover switch
Adjustable
1 SPDT tropicalized changeover switch
Adjustable
2 SPDT tropicalized changeover switch
Adjustable
Process connection
G 1/2 male (standard)
1/2 NPT male
1/4 NPT female
–
3
7
A
B
C
W
E
F
D
V
M
K
N
T
3
6
8
.
101
102
103
104
151
152
153
1)
1)
1)
1)
1)
1)
1)
200
201
202
203
204
205
206
207
208
209
600
601
602
2)
2)
2)
2)
2)
2)
2)
2)
2)
2)
2)
2)
2)
/
Ordering example with options
RP
PE
–
3
A
3
.
101
/
0407
_
9941
Industrial pressure switch
Explosion proof
Diaphragm Viton®
1 SPDT standard changeover switch
Process connection G 1/2 male
Pressure range -50 ... 0 mbar
Option : Mounting on 2" pipe
www.baumer.com
2015-05-22
Option : Stainless steel tag plate and wire
Design and specifications subject to change without notice
Pressure range (mbar)
Pressure range (kPa)
-50 ...
0
-5
...
0
-2 ...
10
-0.2 ...
1
-5 ...
50
-0.5 ...
5
-8 ... 100
-0.8 ...
10
-200...
0
-20 ...
0
0 ... 200
0
...
20
0 ... 400
0 ...
40
Pressure range (bar)
Pressure range (kPa)
-1 ...
0
-100 ...
0
-1 ... 2.5
-100 ... 250
0 ... 0.2
0
...
20
0.05 ...
1
5
... 100
0.5 ... 10
50
... 1000
3.5 ... 25
350 ... 2500
5 ... 50
500 ... 5000
5 ... 100
500 ... 10000
20 ... 150
2000 ... 15000
-1 ... 3.5
-100 ... 350
25 ... 175
2500 ... 17500
30 ... 350
3000 ... 35000
60 ... 600
6000 ... 60000
Options to be added behind the / (see example below)
1)
Only RPPE3
2)
Only RPPE7
.
–
Data sheet A32.06
Page 5 / 5