Tongue Separator Series 1510

Tongue Separator Series 1510
Union Nut Connection
Application
ounting to Bourdon tube pressure gauges or to
M
pressure transmitters, for connection to measuring
points with external thread. Designed for pressure
measurements for which the diaphragm separators
of Series 1060 can not be employed. The flow of the medium can damage the tongue
separator. This must be taken into consideration
when determining the measuring point.
Execution
The
separator is inseparably fixed with the pressure
measuring instrument to a hydraulic measuring
unit, either directly, via a cooling element or via a
capillary tube of stainless steel.
Type of construction
Tongue separator, diaphragm with longitudinal starshaped profile, all parts made of stainless steel, welded.
Connection
Union Nut
Temperature of medium
Up to 80 °C, other temperature limits on request
Hydraulic transmission fluid
Glycerin for direct mounting
Almond oil (sweet) for capillary tube,
others on request
Selection chart
Type
Material of separator body Material of
diaphragm tube
Material of
bottom piece
Tongue separator
Stainless steel 1.4571
Stainless steel 1.4571 G 1 Stainless steel 1.4571
G 3/4 Stainless steel 1.4571 1513
Capillary tube
1.4571
Stainless steel 1.4571
Length m 0,5
1
1,5
2
2,5
3
3,5
4,0
Ordering code
1205
1210
1215
1220
1225
1230
1235
1240
Additional metallic protection hose for capillary tube
Temperature of medium (e. g. 100 °C) Ordering example:
Union nut
Ordering code
1511
1299
9007/0100
DRO 100/811.133/075 / 1512 / 1210 / 1299 / 9007/0100
www.baumer.com
Design and specifications subject to change without notice
Temperature of medium 100 °C
metallic protection hose
Capillary tube 1 m
Separator ordering code
Pressure gauge (see data-sheet D1.131)
Data-sheet A 41 D1.226
Page 1
Dimensions
Dimension drawing
Dimention chart
G
g
øD
ød
S
Sealing ring
G1
G 1/2
30
24
41
A25 x 30 DIN 7603
G 3/4
G 1/4
25
18
36
A18 x 24 DIN 7603
d
G
83
S
19
14
25
D
g
UK/2009-10-01 This data-sheet may only be reproduced in full.
Ø 15
Pressure ranges (directive values)
Mounting to pressure gauge or pressure Transmitter
NS 63
2)
NS 80
NS 100
NS 160
Transmitter
4...1000
Pressure ranges [bar} with union nut connection G 1
2,5...400 2,5...400
6...1000
10...1000
G 3/4
2,5...100
2,5...400
6...1000
–
2)
Only possible with transition piece G 1/4 female and G 1/2 male
www.baumer.com
Design- und Spezifikationsänderungen vorbehalten
Data-sheet A 41 D1.226
Seite 2