PSSN Pressure transmitter for hydrostatic level measurement

Pressure Transmitter
PSSN
Pressure transmitter for hydrostatic level measurement
Main features
High long term stability
Abrasive and chemical resistant
Accuracy class of 1% FS
Ceramic sensor
Applications
Process technic
Hydraulic
Pneumatic
Refrigeration
Water treatment
Car industry
Test benches
Safety
Aerospace
Railways
Shipbuilding
Heavy vehicule
Health care
Biotechnology
Food
Beverage
Pharmaceutical
Petro-chemical
Chemical
HVAC
Energy
Medical gas
Agriculture vehicules
Pumps and compressors
Main characteristics
Long term stability
0.3% FS / Year
Accuracy
1% FS
Medium temperature
5 … 40 °C
(Linearity, hysteresis, repeatability,
error of span and zero point)
www.baumer.com/process
Design and specifications subject to change without notice
Data sheet A11.31
Page 1
Ordering details - PSSN
PSS N 2 1 J15 R A1 U1 90 2 1
Model / type
PSS
N
Material
Stainless steel 1.4404 AISI 316L
2
Accuracy
1.00% FS
1
Pressure range
0 … 6 mH2O
0 … 10 mH2O
0 … 16 mH2O
0 … 20 mH2O
J12
J15
J16
J17
Pressure type
Relative
R
Output signal
4 ... 20 mA
A1
Cable length
PUR
PUR
PUR
PUR
10 meter
15 meter
20 meter
25 meter
U1
U2
U3
U4
Versions
Open
Closed protection cap POM material
90
95
Material diaphragm
Ceramic
C
O-Ring sensor and sealing cable
NBR
www.baumer.com/process
Design and specifications subject to change without notice
1
Data sheet A11.31
Page 2
Model / type PSSN
Technical specification
Electrical specification
Measuring principle
Measuring ranges
Type of pressure
Accuracy (20°)
Thick film on ceramic
0 … 6 mH2O
0 … 10 mH2O
0 … 16 mH2O
0 … 20 mH2O
Relative
1% FS
Output signal
Power Supply
Load impedance
Current output
Insulation resistance
Electrical connections
0.3% FS / Year
5 ms
Housing
Diaphragm
Cable
< 350 ms
Open or closed Version
(see drawing page 4)
Sealing cable gland
O-ring sensor
CE conformity
0.200 kg
0.048 kg / meter
Environment
Temperature
Medium
Storage
Protection rating
Vibration IEC60068-2-6
Stainless steel 1.4404 AISI 316L
Ceramic Al2O3 (96%)
PUR black with integrated
humidity filter
NBR
NBR
Approvals
Weight
Transmitter
Cable
RΩ = (USupply.-8 V) / 0.02 A
>100 MΩ to 500 VDC
PUR Cable with capillary tube
Material
(Linearity, hysteresis, repeatability, error of
span and zero point)
Annual stability
Response time
(10…90%)
Switch on time
Versions
4 … 20 mA
8 … 30 VDC
EMC directive 2004/108/CE
in accordance with EN 61000-6-2,
EN 61000-6-3, EN 61326-1
(Tab.2)
Pressure directive 97/23/CE
5 … 40 °C
-25 … 80 °C
IP 68
1.5 mm p.p (10-57 Hz),
10 g (58 Hz – 2 KHz)
10 cycles within 2.5 h per axis
50 g / 11 ms 100g / 6 ms
10 x Imp. per axis and direction
100 g / 2 ms
4000 x Imp. per axis and direction
0.1 g 2 / Hz (20 Hz - 1 KHz)
30 min per axis and direction
(> 10 g RMS)
Shock IEC600068-2-27
Bump IEC600068-2-27
Random IEC600068-2-64
Measuring Ranges
Pressure (bar)
Measuring range (mH2O) 0 … 6
Pressure range (bar) 0 … 0.6
0 … 10
0 … 16
0 … 20
0…1
0 … 1.6
0…2
Overpressure (bar)
2
2
4
4
Burst pressure (bar)
4
4
5
5
www.baumer.com/process
Design and specifications subject to change without notice
Data sheet A11.31
Page 3
Model / type PSSN
Electrical connections
Cable output with integrated capillary tube
(length according to the ordering code)
Connection
4 … 20 mA
+ Supply : Red
- Supply : Blue
: Shield
Dimensions (mm), connections
EN/2013-07-16 This data sheet may only be reproduced in totality.
&DEOH‘
VHHPDWHULDODQG
OHQJWK
¡ 3661
&RGH
0[
ƒ
¡ ¡
¡ [
0[
&RGH
¡ www.baumer.com/process
Design and specifications subject to change without notice
Data sheet A11.31
Page 4