Pressure Transmitter PSSN Pressure transmitter for hydrostatic level measurement Main features High long term stability Abrasive and chemical resistant Accuracy class of 1% FS Ceramic sensor Applications Process technic Hydraulic Pneumatic Refrigeration Water treatment Car industry Test benches Safety Aerospace Railways Shipbuilding Heavy vehicule Health care Biotechnology Food Beverage Pharmaceutical Petro-chemical Chemical HVAC Energy Medical gas Agriculture vehicules Pumps and compressors Main characteristics Long term stability 0.3% FS / Year Accuracy 1% FS Medium temperature 5 … 40 °C (Linearity, hysteresis, repeatability, error of span and zero point) www.baumer.com/process Design and specifications subject to change without notice Data sheet A11.31 Page 1 Ordering details - PSSN PSS N 2 1 J15 R A1 U1 90 2 1 Model / type PSS N Material Stainless steel 1.4404 AISI 316L 2 Accuracy 1.00% FS 1 Pressure range 0 … 6 mH2O 0 … 10 mH2O 0 … 16 mH2O 0 … 20 mH2O J12 J15 J16 J17 Pressure type Relative R Output signal 4 ... 20 mA A1 Cable length PUR PUR PUR PUR 10 meter 15 meter 20 meter 25 meter U1 U2 U3 U4 Versions Open Closed protection cap POM material 90 95 Material diaphragm Ceramic C O-Ring sensor and sealing cable NBR www.baumer.com/process Design and specifications subject to change without notice 1 Data sheet A11.31 Page 2 Model / type PSSN Technical specification Electrical specification Measuring principle Measuring ranges Type of pressure Accuracy (20°) Thick film on ceramic 0 … 6 mH2O 0 … 10 mH2O 0 … 16 mH2O 0 … 20 mH2O Relative 1% FS Output signal Power Supply Load impedance Current output Insulation resistance Electrical connections 0.3% FS / Year 5 ms Housing Diaphragm Cable < 350 ms Open or closed Version (see drawing page 4) Sealing cable gland O-ring sensor CE conformity 0.200 kg 0.048 kg / meter Environment Temperature Medium Storage Protection rating Vibration IEC60068-2-6 Stainless steel 1.4404 AISI 316L Ceramic Al2O3 (96%) PUR black with integrated humidity filter NBR NBR Approvals Weight Transmitter Cable RΩ = (USupply.-8 V) / 0.02 A >100 MΩ to 500 VDC PUR Cable with capillary tube Material (Linearity, hysteresis, repeatability, error of span and zero point) Annual stability Response time (10…90%) Switch on time Versions 4 … 20 mA 8 … 30 VDC EMC directive 2004/108/CE in accordance with EN 61000-6-2, EN 61000-6-3, EN 61326-1 (Tab.2) Pressure directive 97/23/CE 5 … 40 °C -25 … 80 °C IP 68 1.5 mm p.p (10-57 Hz), 10 g (58 Hz – 2 KHz) 10 cycles within 2.5 h per axis 50 g / 11 ms 100g / 6 ms 10 x Imp. per axis and direction 100 g / 2 ms 4000 x Imp. per axis and direction 0.1 g 2 / Hz (20 Hz - 1 KHz) 30 min per axis and direction (> 10 g RMS) Shock IEC600068-2-27 Bump IEC600068-2-27 Random IEC600068-2-64 Measuring Ranges Pressure (bar) Measuring range (mH2O) 0 … 6 Pressure range (bar) 0 … 0.6 0 … 10 0 … 16 0 … 20 0…1 0 … 1.6 0…2 Overpressure (bar) 2 2 4 4 Burst pressure (bar) 4 4 5 5 www.baumer.com/process Design and specifications subject to change without notice Data sheet A11.31 Page 3 Model / type PSSN Electrical connections Cable output with integrated capillary tube (length according to the ordering code) Connection 4 … 20 mA + Supply : Red - Supply : Blue : Shield Dimensions (mm), connections EN/2013-07-16 This data sheet may only be reproduced in totality. &DEOH VHHPDWHULDODQG OHQJWK ¡ 3661 &RGH 0[ ¡ ¡ ¡ [ 0[ &RGH ¡ www.baumer.com/process Design and specifications subject to change without notice Data sheet A11.31 Page 4