TRPE03EL2C000E1G - Oplink Communications, Inc

OC-3/STM-1 LR-2/L-1.2 SFP Transceivers
with Digital Diagnostics
TRPE03EL2-E1G Single Mode
Pb
Produ c t D es c rip tion
The TRPE03EL2-E1G SFP series of fiber optic transceivers w ith
integrated digital diagnostics monitoring functionality provide a
quick and reliable interface for long reach (LR2)applications. The
diagnostic functions, alarm and w arning features as described
in the Multi-Source Agreement (MSA )document,SFF-8472 (Rev.
9.4),are provided via an I2C serial interface.
Available products under this series are compliant w ith applicable
SON ET/SD H standards for OC-3/STM-1. A ll modules satisfy Class I
Laser Safety requirements in accordance w ith the U .S. FD A /CD RH
and international IEC-60825 standards.
The TRPE03EL2-E1G transceivers connect to standard 20-pad
SFP connectors for hot plug capability. This allow s the system
designer to make configuration changes or maintenance by
simply plugging in different types of transceivers w ithout
removing the pow er supply from the host system.
The transceivers have colored bail-type latches,w hich offer an
easy and convenient w ay to release the modules. The latch is
compliant w ith the SFP MSA .
F ea tu res
þ Compatible w ith SFP MSA
þ Compliant w ith SON ET/SD H OC-3/STM-1 (155Mb/s)
þ Lead Free D esign & Fully RoH S Compliant
þ SON ET/SD H LR2 Reach
The transmitter design incorporates a highly reliable 1550nm
InG aA sP laser and a driver circuit. The receiver features a
transimpedance amplifier IC optimized for high sensitivity and
w ide dynamic range. The transmitter and receiver D ATA interfaces
are AC-coupled internally. LVTTL Transmitter D isable control
input and Loss of Signal output interfaces are also provided.
þ D igital D iagnostics through Serial Interface
The transceivers operate from a single +3.3V pow er supply
over tw o operating case temperature ranges of -5°C to +70°C
(Commercial),or -40°C to +85°C (Industrial). The housing is made
of metal for EMI immunity.
þ Excellent EMI & ESD Protection
þ Internal Calibration for D igital D iagnostics
þ Eye Safe (Class I Laser Safety)
þ D uplex LC Optical Interface
þ -40°C to +85°C Operating Case Temperature Option
þ H ot-pluggable
þ TX Fault & Loss of Signal Outputs
þ TX D isable Input
þ Single +3.3V Pow er Supply
A bsolute Maximum R atings
Parameter
Storage Temperature
Operating Case Temperature1
Commercial
Industrial
Symbol
Minimum
Maximum
Units
Tst
- 40
+ 85
°C
-5
+ 70
- 40
+ 85
Top
°C
Supply Voltage
Vcc
0
+ 5.0
V
Input Voltage
Vin
0
Vcc
V
Measured on top side of SFP module at the front center vent hole of the cage.
1
An Oplink Company
S0123,Rev.02
2011-03-30
TRPE 0 3E L2-E 1G Single Mode
Transmitter Performance C haracteristics (Over Operating Case Temperature, VCC = 3.13 to 3.47V)
All parameters guaranteed only at typical data rate
Parameter
Symbol
Minimum
Typical
Maximum
Units
Operating D ata Rate1
B
-
156
-
Mb/s
Average Optical Output Pow er (coupled into single mode
fiber),50% duty cycle
PO
- 5.0
- 3.0
0
dBm
Phi/
Plo
10
-
-
dB
1480
1550
1580
nm
-
-
1
nm
30
-
-
dB
Extinction Ratio
Center W avelength
c
Spectral W idth (-20dB)
!
20
Side Mode Suppression Ratio
SM SR
Optical Output Eye
Compliant w ith Telcordia G R-253-CORE and ITU -T Recommendation G .957
1
D ata rate ranges from 50Mb/s to 266Mb/s. H ow ever,some degradation may be incurred in overall performance.
R eceiver Performance C haracteristics (Over Operating Case Temperature, VCC = 3.13 to 3.47V)
All parameters guaranteed only at typical data rate
Parameter
Symbol
Minimum
Typical
Maximum
Units
B
-
156
-
Mb/s
Receiver Sensitivity (10 BER)
Pmin
- 34.0
- 36.0
-
dBm
Maximum Input Optical Pow er (10-10 BER)2
Pmax
- 7.0
0
-
dBm
Increasing Light Input
Plos+
-
-
- 34.0
D ecreasing Light Input
Plos-
- 45.0
-
-
Increasing Light Input
t_l
oss_o"
#
-
-
100
D ecreasing Light Input
t_l
oss_on
2.3
-
100
Operating D ata Rate
1
-10
2
LOS Thresholds
LOS Timing D elay
LOS H ysteresis
-
W avelength of Operation
Receiver Reflectance (LR-2 only)
1
-
dBm
µs
0.5
1.5
-
dB
1100
-
1600
nm
-
-
- 25.0
dB
D ata rate ranges from 50Mb/s to 266Mb/s. H ow ever,some degradation may be incurred in overall performance.
Specified in average optical input pow er and measured w ith 223-1 PRBS at 156Mb/s,1550nm for LR-2.
2
Laser Safety
Laser Safety: A lltransceivers are C lass I Laser products
per FD A /C D R H and IEC -60825 standards.They m ust be
operated under speci! ed operating conditions.
Oplink Communications, Inc.
D ATE OF MA N U FACTU RE:
This product complies w ith
21 CFR 1040.10 and 1040.11
Meets Class I Laser Safety Requirements
Oplink Communications,
I
nc.
2
S0123,Rev.02
2011-03-30
TRPE 0 3E L2-E 1G Single Mode
Transmitter Electrical Interface (Over Operating Case Temperature, VCC = 3.13 to 3.47V)
Parameter
Symbol
Minimum
Typical
Maximum
Units
Input Voltage Sw ing (TD + & TD -)1
VPP-DIF
0.35
-
2.4
V
Input H IG H Voltage (TX D isable)
VIH
2.0
-
VCC
V
Input LOW Voltage (TX D isable)2
VIL
0
-
0.8
V
Output H IG H Voltage (TX Fault)3
VOH
2.0
-
VCC#+ 0.3
V
Output LOW Voltage (TX Fault)
VOL
0
-
0.8
V
2
3
D iff erential peak-to-peak voltage.
2
There is an internal 4.7 to 10kΩ pull-up resistor to VccT.
3
Open collector compatible,4.7 to 10kΩ pull-up resistor to Vcc (H ost Supply Voltage).
1
R eceiver Electrical Interface (Over Operating Case Temperature, VCC = 3.13 to 3.47V)
Parameter
Symbol
Minimum
Typical
Maximum
Units
VPP-DIF
0.6
-
2.0
V
Output H IG H Voltage (LOS)2
VOH
2.0
-
VCC#+ 0.3
V
Output LOW Voltage (LOS)
VOL
0
-
0.5
V
Output Voltage Sw ing (RD + & RD -)1
2
D iff erential peak-to-peak voltage across external 100Ω load.
Open collector compatible,4.7 to 10kΩ pull-up resistor to Vcc (H ost Supply Voltage).
1
2
Electrical Pow er Supply C haracteristics (Over Operating Case Temperature, VCC = 3.13 to 3.47V)
Parameter
Symbol
Minimum
Typical
Maximum
Units
Supply Voltage
VCC
3.13
3.3
3.47
V
Supply Current
ICC
-
190
270
mA
Module D efinition
MO D _D EF(0)
pin 6
MO D _D EF(1)
pin 5
MO D _D EF(2)
pin 4
Interpretation by H ost
TTL LOW
SCL
SD A
Serial module definition protocol
Electrical Pad Layout
H ost B oard C onnector Pad Layout
20
TX G N D
1
TX G N D
19
TD - (TX D ATA IN -)
2
TX Fault
1
18
TD + (TX D ATA IN +)
3
TX D isable
2
17
TX G N D
4
MOD _D EF(2)
3
16
VccTX
5
MOD _D EF(1)
4
15
VccRX
6
MOD _D EF(0)
14
RX G N D
7
N O CON N ECTION
6
13
RD + (RX D ATA OU T+)
8
LOS
7
12
RD - (RX D ATA OU T-)
9
RX G N D
8
11
RX G N D
10
RX G N D
9
Top of Board
Oplink Communications,
I
nc.
Tow ard
B ezel
5
10
Bottom of Board
(as viewed thru top of board)
3
20
19
18
17
16
15
Tow ard
A SIC
14
13
12
11
S0123,Rev.02
2011-03-30
TRPE 0 3E L2-E 1G Single Mode
Example of SFP host board schematic
Vcc
3.3V
1mH coi
lorferri
te bead
(<0.2W seri
esresi
stance)
Vcc
3.3V
+
10
0.1
0.1
+
R R R
16
2
15
10
0.1
SFP
3
TX Di
sabl
e
TX DATA IN+
50W l
i
ne
13
19
12
50W l
i
ne
TX DATA IN-
LOS
MOD_DEF(2)
MOD_DEF(1)
MOD_DEF(0)
6
18
R
TX Faul
t
8
4
5
50W l
i
ne
R
50W l
i
ne
RX DATA OUT+
to 50W load
RX DATA OUTto 50W load
1,9,10,11,14,17,20
R:4.7 to 10kΩ
CA P Values in µF
A pplication N otes
Electrical Interface: A ll signal interfaces are compliant w ith
the SFP MSA specification. The high speed D ATA interface is
differential AC-coupled internally w ith 1μF and can be directly
connected to a 3.3V SERD ES IC. A ll low speed control and sense
output signals are open collector TTL compatible and should
be pulled up w ith a 4.7 - 10kΩ resistor on the host board.
is TTL LOW . W hen the host system detects this condition,
it activates the serial protocol (standard tw o-w ire I2C serial
interface) and generates the serial clock signal (SCL). The
positive edge clocks data into the EEPROM segments of the
SFP that are not w rite protected,and the negative edge clocks
data from the SFP.
Loss of Signal (LOS): The Loss of Signal circuit monitors the
level of the incoming optical signal and generates a logic H IG H
w hen an insufficient photocurrent is produced.
The serial data signal (SD A ) is for serial data transfer. The
host uses SD A in conjunction w ith SCL to mark the start and
end of serial protocol activation. The supported monitoring
functions are temperature,voltage,bias current,transmitter
pow er,average receiver signal,all alarms and w arnings,and
softw are monitoring of TX Fault/LOS. The device is internally
calibrated.
TX Fault: The output indicates LOW w hen the transmitter
is operating normally,and H IG H w ith a laser fault including
laser end-of-life. TX Fault is an open collector/drain output
and should be pulled up w ith a 4.7 - 10kΩ resistor on the host
board. TX Fault is non-latching (automatically deasserts w hen
fault goes aw ay).
The data transfer protocol and the details of the mandatory
and vendor specific data structures are defined in the SFP MSA ,
and SFF-8472,Rev. 9.4.
TX Disable: W hen the TX D isable pin is at logic H IG H , the
transmitter optical output is disabled (less than -45dBm).
Pow er Supply and G rounding: The pow er supply line should
be w ell-filtered. A ll 0.1μF pow er supply bypass capacitors
should be as close to the transceiver module as possible.
Serial Identification and Monitoring: The module definition
of SFP is indicated by the three module definition pins,
MOD _D EF(0),MOD _D EF(1)and MOD _D EF(2). U pon pow er up,
MOD _D EF(1:2)appear as N C (no connection),and MOD _D EF(0)
Oplink Communications,
I
nc.
4
S0123 ,Rev.02
2011-03-30
TRPE 0 3E L2-E 1G Single Mode
Package O utline
41.80
9.20
[.362]
[.588]
14.94
13.62
[.536]
[1.646]
45.00
[1.772]
[.257]
1.99
[.078]
6.25
0.60
[.024]
6.54
8.46
[.411]
10.45
[.333]
[.470]
11.94
4
6
3
3
5L
and
ingP
kwyF
r
e
mont,
CA9
4
5
3
8T
e
l:
(
5
1
0
)9
3
3
7
2
0
0F
ax
:
(
5
1
0
)9
3
3
7
3
0
0E
mail:
S
ale
s@Oplink.
com •www.
oplink.
com
[.246]
2.29
[.090]
13.80
[.543]
1.49
[.059]
2.50
[.098]
0.60
[.024]
0.45
[.018]
D imensions in inches [mm]
D efault tolerances:
.xxx = ± .005”,.xx = ± .01”
O rdering Information
Part N umber
O perating Temperature
TRPE03EL2C000E1G
- 5°C to +70°C
TRPE03EL2I000E1G
- 40°C to +85°C
Latch
C olor
N ominal
W avelength
SO N ET/SD H
Standards
D istance1
W hite
1550nm
LR-2/L-1.2
100/80km
These are target distances to be used for classification and not for specification,per Telcordia G R-253-CORE/ITU -T Recommendation G .957.
1
Oplink Communications,Inc. reserves the right to make changes in equipment design or specifications w ithout notice. Information supplied by Oplink Communications,Inc. is believed to be accurate and reliable. H ow ever,no responsibility is assumed by Oplink Communications,Inc. for its use nor for any infringements
of third parties,w hich may result from its use. N o license is granted by implication or otherw ise under any patent right of Oplink Communications,Inc.
© 2011,Oplink Communications,Inc.
5
S0123,Rev.02
2011-03-30