Renewable Energy Selector Guide

Renewable Energy
Selector Guide
CX–SERIES
C–SERIES
E–SERIES
F–SERIES
NUMBER OF POLES
1- 2, + Auxiliary Switch Pole
1-6 (handle); 1-3 (rocker)
1-6
1-3
ACTUATOR STYLE
Handle, 1 per pole
Sealed Metal Toggle Handle,
Rocker
Handle
Handle
AVAILABLE DELAYS
DC: Instantaneous, Ultrashort,
Short,
Medium & Long
Instantaneous, Ultrashort,
Short, Medium & Long, AC,
DC, AC/DC High Inrush - Short,
Medium & Long AC and DC
Instant, Short, Medium &
Long - AC, DC, and
AC/DC High Inrush Short, Medium & LongAC, DC, and AC/DC
Short, Medium & Long
DC, AC
MAXIMUM CURRENT
& VOLTAGE RATINGS
UL Recognized .2 -125A,
600VDC
UL Listed .2-15A, 250/500VDC
UL Listed
0.02-250A@80VDC
0.02-60A@125VDC
0.02-70A@120VAC
0.02-20A@240VAC
ULRecognized
0.02-30A@480WYE
/277VAC2-pole, 1Ø, 3-pole, 3Ø
0.02-50A@277VAC
0.02-100A@250VAC,80VDC
0.02-100A@120/240VAC,
65VDC
UL Listed
0.02-100A@240VAC,
65VDC, 125VDC
ULRecognized
0.02-100A@277VAC,
160VDC, 1-pole
0.02-100A@600VAC,
2-pole 1Ø, 3 pole 3Ø
0.02-120A@125VDC,
1-pole
UL489 Listed:
50-250A@125VDC
100-250A@120/240VAC
100-250A@277VAC
100-250A@208Y/120 3Ø
UL489A Listed
250-700A@125VDC
MAXIMUM
INTERRUPTING
CAPACITY
Up to 10,000 UL Listed and UL
recognized
UL Listed
50000A@80VDC,
10,000A@120VAC,
5000A@125VDC,
240VAC
ULRecognized
7500A@80VDC
3000A@125/250VAC,
ULonly
5000A@250VAC
5000A@480WYE/277V
AC w/fuse backup
UL Listed
25000A@65VDC
5000A@125VDC&
240VAC
ULRecognized
5000A@125VDC
5000A@600VAC,without
fuse backup
10000A@600VAC,
w/fuse backup
50000A@125VDC
10000A, 120/240, 277,
208Y/120
AUXILIARY
SWITCH RATING
20A, 80VDC (GO circuit)
10.1A@250VAC
0.1A@125VAC (gold contacts)
0.5A@65VDC
10.1A@250VAC
1.0A@65VDC
0.1A@80VDC
10.1A@250VAC
0.5A@65VDC
0.1A@80VDC
AVAILABLE CIRCUITS
Series Trip
Series, Shunt,Relay,
Switch Only, Series
w/Remote Shutdown,
Relay & Shunt Trip Dual
Coil, Mid-Trip with Alarm
Switch
Series, Shunt, Relay,
Switch Only, Series
w/Remote Shutdown
Series & Switch Only
with or without Metering
Shunt
TERMINAL OPTIONS
10-32 or M5 Screw Terminals
1/4-20 or
M6 Threaded Stud
10-32 Stud, 1/4-20 Stud,
0-32 Screw w/ saddle
clamp, Clip Terminal,
1/4 & 7/16 Push-In
10-32 Stud, 1/4-20 Stud
0-32 Screw, 1/4-20
Screw, Box Wire
Connector
3/8-16 Stud, 3/8-16
Screw& Box Wire
Connector
MOUNTING METHOD
Threaded insert: #6-32
UNC-2B, or
M3X0.5-6H B ISO (2 per pole)
Threaded inserts
Rear or Front Panel
Rear or Front Panel
AGENCY APPROVALS
UL489, UL1077,
TUV (EN60934-2)
UL, CSA, VDE, TUV,
UL1500, UL489, UL489A
UL, CSA, VDE,
UL1500, UL489
CUL,TUV, UL489,
UL489A
ENVIRONMENTAL
PROTECTION
MIL-PRF-55629 &
MIL-STD-202 Method 213,
MIL-PRF-39019F
when mounted in panel
MIL-PRF-55629 &
MIL-STD-202 Method 213,
MIL-PRF-39019F
when mounted in panel
MIL-PRF-55629 &
MIL-STD-202F
Method 213
MIL-PRF-55629 &
MIL-STD-202F
Method 213
OPERATING
TEMPERATURE
-40° C to +85° C
-40° C to +85° C
-40° C to +85° C
-40° C to +85° C
RE-SG_01_2014
60 Johnson Avenue • Plainville, CT 06062 • Phone: (860) 793–9281 • Fax: (860) 793–9231
Email: [email protected] • www.carlingtech.com