RENEWABLE ENERGY Circuit Breakers & Disconnects SELECTOR GUIDE CIRCUIT PROTECTION CX-Series C-Series E-Series F-Series Number of Poles 1-2, + auxiliary switch pole 1-6 (handle) 1-3 (rocker & metal toggle) Actuator Style handle, 1 per pole sealed metal toggle handle rocker handle handle Available Delays DC: instant, ultrashort, short, medium & long AC, DC, AC/DC: instant, ultrashort, short, medium & long AC, DC: high inrush-short, medium & long AC, DC, AC/DC: instant, short, medium & long AC, DC, AC/DC: high inrushshort, medium & long AC, DC: short, medium & long Max Current & Voltage Ratings Max Interrupting Capacity UL Recognized 0.2-115A@600VDC UL Listed 0.2-15A@250/500VDC 0.2-50A@205/410VDC UL Listed and UL Recognized up to 10,000 amps UL Listed: 0.02-250A@80VDC 0.1-100A@125VDC 0.02-70A@120VAC 0.02-20A@240VAC UL Recognized: 0.02-30A@480WYE/277VAC 2 Pole, 1Ø; 3 Pole, 3Ø 0.02-50A@277VAC 0.02-100A@250VAC, 80VDC 0.02-100A@120V/ 240VAC, 65VDC UL Listed: 50000A@80VDC, 1P only 10000A@120VAC 5000A@125VDC/240VAC UL Recognized: 7500A@80VDC 3000A@125/250VAC, UL only 5000A@250VAC 1-6 1-3 UL Listed 0.02-100A@240VAC, 80VDC, 125VDC UL Recognized 0.02-100A@277VAC, 160VDC, 1 pole 0.02-100A@600VAC, 2 Pole 1Ø, 3 pole 3Ø 0.02-120A@125VDC, 1 pole UL Listed 50000A@80VDC 10000A@125VDC & 240VAC-5KA UL Recognized 5000A@125VDC 5000A@600VAC, without fuse listed construction backup fuse backup with fuse backup 5000A@480WYE/277VAC with UL489 Listed: 50-250A@125VDC 100-250A@120/240VAC 100-250A@277VAC 100-250A@208Y/120, 3ØVAC UL489A Listed 250-700A@125VDC 50000A@125VDC 10000A@120/240, 277, 208Y/120VAC 10000A@600VAC, Auxiliary Switch Rating 20A@80VDC (GO circuit) 10.1A@250VAC 0.1A@125VAC (gold contacts) 0.5A@80VDC 10.1A@250VAC 1.0A@65VDC 0.1A@80VDC 10.1A@250VAC 0.5A@65VDC 0.1A@80VDC Available Circuits series trip series, shunt, relay, switch only, series with remote shutdown, relay & shunt trip dual coil, midtrip with alarm switch series, shunt,relay, switch only, series with remote shutdown series & switch only with or without metering shunt Terminal Options 10-32 or M5 screw terminals 1/4-20 or M6 threaded stud 10-32 stud, 1/4-20 stud, 10-32 screw with saddle clamp, 7/16 clip & push-In 10-32 stud, 1/4-20 stud, 0-32 screw, 1/4-20 screw, box wire connector 3/8-16 stud, 3/8-16 screw & box wire connector Mounting Method threaded insert: #6-32 UNC2B, or M3X0.5-6H B ISO (2 per pole) threaded inserts rear or front panel rear or front panel Agency Approvals UL489, UL1077, TUV (EN60934-2) UL, CSA, VDE, TUV, UL1500, UL489, UL489A UL, CSA, VDE, UL1500, UL489 cUL,TUV, UL489, UL489A *Options and approvals shown may apply to specific construction combinations only, consult factory for clarification. Manufacturer reserves the right to change product specifications without prior notice. RENEWABLE ENERGY-SG_02_2016 60 Johnson Avenue | Plainville, CT 06062 | Phone: (860) 793-9281 | Fax: (860) 793-9231 | Web: www.carlingtech.com