Renewable Energy Selector Guide [pdf]

RENEWABLE
ENERGY
Circuit Breakers & Disconnects
SELECTOR GUIDE
CIRCUIT PROTECTION
CX-Series
C-Series
E-Series
F-Series
Number of Poles
1-2, + auxiliary switch pole
1-6 (handle)
1-3 (rocker & metal toggle)
Actuator Style
handle, 1 per pole
sealed metal toggle
handle
rocker
handle
handle
Available Delays
DC: instant, ultrashort, short,
medium & long
AC, DC, AC/DC: instant,
ultrashort, short, medium & long
AC, DC: high inrush-short,
medium & long
AC, DC, AC/DC: instant, short,
medium & long
AC, DC, AC/DC: high inrushshort, medium & long
AC, DC: short, medium & long
Max Current &
Voltage Ratings
Max Interrupting
Capacity
UL Recognized
0.2-115A@600VDC
UL Listed
0.2-15A@250/500VDC
0.2-50A@205/410VDC
UL Listed and UL Recognized
up to 10,000 amps
UL Listed:
0.02-250A@80VDC
0.1-100A@125VDC
0.02-70A@120VAC
0.02-20A@240VAC
UL Recognized:
0.02-30A@480WYE/277VAC
2 Pole, 1Ø; 3 Pole, 3Ø
0.02-50A@277VAC
0.02-100A@250VAC, 80VDC
0.02-100A@120V/ 240VAC,
65VDC
UL Listed:
50000A@80VDC, 1P only
10000A@120VAC
5000A@125VDC/240VAC
UL Recognized:
7500A@80VDC
3000A@125/250VAC,
UL only 5000A@250VAC
1-6
1-3
UL Listed
0.02-100A@240VAC, 80VDC,
125VDC
UL Recognized
0.02-100A@277VAC, 160VDC,
1 pole
0.02-100A@600VAC,
2 Pole 1Ø, 3 pole 3Ø
0.02-120A@125VDC, 1 pole
UL Listed
50000A@80VDC
10000A@125VDC &
240VAC-5KA
UL Recognized
5000A@125VDC
5000A@600VAC, without fuse
listed construction
backup
fuse backup
with fuse backup
5000A@480WYE/277VAC with
UL489 Listed:
50-250A@125VDC
100-250A@120/240VAC
100-250A@277VAC
100-250A@208Y/120,
3ØVAC
UL489A Listed
250-700A@125VDC
50000A@125VDC
10000A@120/240, 277,
208Y/120VAC
10000A@600VAC,
Auxiliary Switch
Rating
20A@80VDC (GO circuit)
10.1A@250VAC
0.1A@125VAC (gold contacts)
0.5A@80VDC
10.1A@250VAC
1.0A@65VDC
0.1A@80VDC
10.1A@250VAC
0.5A@65VDC
0.1A@80VDC
Available Circuits
series trip
series, shunt, relay, switch only,
series with remote shutdown,
relay & shunt trip dual coil, midtrip with alarm switch
series, shunt,relay,
switch only, series
with remote shutdown
series & switch only
with or without metering shunt
Terminal Options
10-32 or M5 screw terminals
1/4-20 or M6 threaded stud
10-32 stud, 1/4-20 stud,
10-32 screw with saddle
clamp, 7/16 clip & push-In
10-32 stud, 1/4-20 stud, 0-32
screw, 1/4-20 screw, box wire
connector
3/8-16 stud, 3/8-16 screw &
box wire connector
Mounting Method
threaded insert: #6-32 UNC2B, or M3X0.5-6H B ISO (2
per pole)
threaded inserts
rear or front panel
rear or front panel
Agency Approvals
UL489, UL1077, TUV
(EN60934-2)
UL, CSA, VDE, TUV,
UL1500, UL489, UL489A
UL, CSA, VDE, UL1500, UL489
cUL,TUV, UL489, UL489A
*Options and approvals shown may apply to specific construction combinations only, consult factory for clarification.
Manufacturer reserves the right to change product specifications without prior notice.
RENEWABLE ENERGY-SG_02_2016
60 Johnson Avenue | Plainville, CT 06062 | Phone: (860) 793-9281 | Fax: (860) 793-9231 | Web: www.carlingtech.com