The M-Series is a low cost, miniature hydraulic/magnetic
circuit breakers ideally designed for demanding
applications requiring space saving features, aesthetics and
snap-in front panel mounting.
Its newest design features a compact, space saving,
vertically mounted parallel pole configuration, which
is UL489A listed up to 50 amps and is well suited for
telecommunication equipment fitting in one rack unit.
Furthermore, it features two uniquely designed terminals
that provide the highest level of balanced circuit
protection.
In addition, these circuit breakers feature various styling
options allowing for design flexibility. They are available
in choices of rocker actuator styles and colors, including
paddle and baton style handle actuators, push-to-reset
and push-pull pushbutton actuators, Visi-Rocker two color
actuators as well as non-illuminated or illuminated rocker
versions with LED or neon bulbs. The exclusive Rockerguard
bezel helps prevent inadvertent actuation and wiping
contact design insures long-term reliability. The M-Series
circuit breakers are available in 1 & 2 poles or parallel poles,
0.02 to 50 amps, up to 250VAC or 80VDC with choices of
time delays, terminals, panel hardware, actuator styles,
colors, and imprinting.
Carling Technologies, Inc.
60 Johnson Avenue • Plainville, CT 06062
Phone: (860) 793-9281 • Fax: (860) 793-9231
Email: [email protected] • www.carlingtech.com
Features:
ŠŠ Parallel pole configuration well suited for one rack unit
ŠŠ Compact design
Applications:
ŠŠ Communication equipment
ŠŠ Vehicles
ŠŠ Marine
ŠŠ Generators
ŠŠ Power supplies
ŠŠ Medical equipment
2 | M-Series Circuit Breaker - General Specifications
Mechanical
Electrical
Maximum Voltage
125/250 VAC 50/60 Hz, 80 VDC (See Rating Tables.)
Current Ratings
Standard current coils: 0.100, 0.250, 0.500, 0.750, 1.00 thru 15.0 in 1 amp increments, 18.0, 20.0, 25.0, 30.0. Other ratings available - see Ordering Scheme.
Auxiliary Switch Rating SPDT; 7A 250VAC, 7A (Res) 28VDC, 4A (Ind.) 28VDC, 0.25A 80VDC (Res) (silver contacts), 0.1A 125VAC (gold contacts).
Insulation Resistance
Minimum of 100 Megohms at 500 VDC.
Dielectric Strength
UL, CSA 1500V, 50/60 Hz for one minute between all electrically isolated terminals. M-Series Circuit Breakers comply with the
8mm spacing and 3750 V 50/60Hz
dielectric requirements from
hazardous voltage to operator
accessible surfaces, per Publications IEC 380, 435, 950, EN 60950 and VDE 0805.
Resistance, Impedance Values from Line to Load Terminal - based on Series Trip Circuit Breaker.
RESISTANCE PER POLE VALUES
from Line to Load Terminals
(Values Based on Series Trip Circuit Breaker)
CURRENT
(AMPS)
TOLERANCE
(%)
0.10 - 20.0
20.1 - 50.0
±25
±35
Pulse Tolerance Curves
*Manufacturer reserves the right to change product specification without prior notice.
Endurance
10,000 ON-OFF operations @ 6 per minute with rated Current and Voltage.
Trip Free
All M-Series Circuit Breakers will trip on overload, even when actuator is forcibly held in the ON position.
Trip Indication
The actuator moves positively to the OFF position when an overload causes the circuit breaker to trip.
Physical
Number of Poles
Internal Circuit Configs.
Weight
Standard Colors
1 or 2
Series with or without Auxiliary Switch.
Switch Only with or without Auxiliary Switch.
Approximately 30 grams/pole (Approximately 1.07 ounces/pole)
See Ordering Scheme.a
Environmental
Designed in accordance with requirements of specification
MIL PRF-55629 & MIL-STD-202G as follows:
Shock
Withstands 100 Gs, 6ms, sawtooth while carrying rated current per
Method 213, Cond. I. Instantaneous curves tested at 80% of rated current.
Vibration
Withstands 0.060” excursion from 10-55 Hz, and 10 Gs 55-500 Hz, at rated current per Method
204C, Test Condition A.
Instantaneous curves tested at
80% of rated current.
Moisture Resistance
Method 106D, i.e., ten 24-hour
cycles @ + 25°C to +65°C, 80
98% RH.
Salt Spray
Method 101, Condition A (90-95% RH @ 5% NaCl Solution, 96 hrs).
Thermal Shock
Method 107D, Condition A (Five cycles @ -55°C to +25°C to +85°C to +25°C).
Operating Temperature -40° C to +85° C
Chemical Resistance
Only the outside surfaces of the
case and the handles may be
cleaned with detergents or
alcohol. Organic (hydrocarbon
based) solvents are not
recommended because they attack plastics. Caution should be taken when solvents are used
to clean and remove flux from terminals. Lubricants should not be introduced into the handle/
bushing openings
60 Johnson Avenue • Plainville, CT 06062 • Phone: (860) 793–9281 • Fax: (860) 793–9231
Email: [email protected] • www.carlingtech.com
M-Series Circuit Breaker - General Specifications | 3
Electrical Tables
Table A: Lists UL Recognized and CSA Accepted configurations & performance capabilities as a Component Supplementary
Protector.
Table A Notes:
1 Polarity Sensitive
2 Available only with Special Catalog Number. Consult Factory.
3 Requires Branch Circuit Backup with a UL Listed type K-5 or RK-5 fuse rated 30 Amps maximum
4 Requires Branch Circuit Backup with a UL Listed type K-5 or RK-5 fuse rated 60 Amps maximum
Table B: Lists UL Recognized,CSA Accepted and TUV and VDE Certified configurations and performance capabilities as a
Component Supplementary Protector.
Table B Notes:
1 Polarity Sensitive
2 Available only with Special Catalog Number. Consult Factory.
3 Requires Branch Circuit Backup with a UL Listed type K-5 or RK-5 fuse rated 30 Amps maximum
4 TUV only, not VDE
5 Requires backup protection with a thermal magnetic circuit breaker rated 32 amps and having a Type C trip characteristic per EN60898/DIN VDE 0641 (C32A) for ratings greater than 15amps, and a thermal magnetic circuit breaker rated 16 amps and having a Type C trip characteristic per EN60898/DIN VDE 0641 (C16A) for ratings 15 amps and less
60 Johnson Avenue • Plainville, CT 06062 • Phone: (860) 793–9281 • Fax: (860) 793–9231
Email: [email protected] • www.carlingtech.com
4 | M-Series Circuit Breaker - General Specifications
Electrical Tables
Table C: Lists UL489A Listed and TUV Certified configurations and performance capabilities for use in Communications Equipment.
M-SERIES TABLE C: UL489A Listed
Table C Notes:
1
Available only with Special Caralog Number
Table D: Lists UL489A Listed configurations and performance capabilities for use in Communications Equipment.
M-SERIES TABLE D: Parallel Pole Construction UL489A Listed
(COMMUNICATIONS EQUIPMENT - POLARITY SENSITIVE)
SERIES
INTERRUPTING
CAPACITY (AMPS)
MAX. RATING
FREQUENCY
CURRENT
RATING
GENERAL
PURPOSE
AMPS
80
DC
31-50
2
600
65 1
DC
31-50
2
1000
VOLTAGE
CIRCUIT
CONFIGURATION
POLES
BREAKING
WITHOUT BACKUP
FUSE
UL489A
Table D Notes:
1. Available
SpecialCaralog
Catalog
Number. Consult Factory.
1
Availableonly
only with
with Special
Number
Agency Certifications
UL Recognized
UL Standard 1077
UL Listed
UL Standard 489A
Component Recognition Program
as Protectors, Supplementary
(Guide CCN/QVNU2, File E75596)
Communications Equipment
(Guide CCN/DITT, File E189195)
CSA Accepted
Component Supplementary
Protector (Class 3215 30, File
047848 0 000)
CSA Standard C22.2 No. 235
VDE Certified
EN60934, VDE 0642 under File
10537
TUV Certified
EN60934, under License No.
R9671109
60 Johnson Avenue • Plainville, CT 06062 • Phone: (860) 793–9281 • Fax: (860) 793–9231
Email: [email protected] • www.carlingtech.com
M-Series Parallel Pole Rocker - Ordering Scheme | 5
M E 2
1
Series
2
Actuator
3
Poles
P
4
Circuit
D2
5
Frequency
& Delay
650
5
6
Current
Rating
7
Terminal
A 1 2
9
8
Illumination Actuator
Color &
Legend
10
Legend
B
11
Bezel
Color
7 TERMINAL
1 SERIES
M
A
5
Push in Stud
10-32 Screw (Bus Type)
2 ACTUATOR
Single Color Rocker Two Color Visi-Rocker Single Color Translucent Rocker
A
Angled D
Indicate ON F
Angled
B
Flat E
Indicate OFF G Flat
8 ILLUMINATION
Non-Illuminated
A
Non-Illuminated
9 ACTUATOR COLOR & LEGEND
Actuator Visi1 Legend
1
White 2Black
3Red
4Green
5Blue
6
Yellow 7
Gray 8
Orange 3 POLES
2Two
4 CIRCUIT/AUXILIARY SWITCH2
P Series Trip Current (Parallel Pole)
with Auxiliary Switch, Silver Contacts
Q Series Trip Current (Parallel Pole)
with Auxiliary Switch, Gold Contacts
R Series Trip Current (Parallel Pole)
5 FREQUENCY & TIME DELAY
D2 D4 DC Short
DC Medium
6 CURRENT RATING (AMPERES)
CODE
631
635
640
645
650
AMPERES
31.000
35.000
40.000
45.000
50.000
Black
White
White
White
White
Black
Black
Black
10 LEGEND
.110 x 0.20 Q.C
.110 x 0.20 Q.C
2
3
6
7
ON - OFF Vertical
ON - OFF Horizontal
Dual Vertical
Dual Horizontal
11 BEZEL COLOR
A
B
G
1
2
7
White without Rockerguard
Black without Rockerguard
Gray without Rockerguard
White with Rockerguard
Black with Rockerguard
Gray with Rockerguard
12 AGENCY APPROVAL
T
UL 489A Listed
Notes:
1 Reminder of Rocker same color as Visi
2 Aux Switch only available with screw terminals
60 Johnson Avenue • Plainville, CT 06062 • Phone: (860) 793–9281 • Fax: (860) 793–9231
Email: [email protected] • www.carlingtech.com
T
12
Agency
Approval
6 | M-Series Parallel Pole - Handle / Push Button - Ordering Scheme
M M 2
1
Series
2
Actuator
3
Poles
P
4
Circuit
D2
5
Frequency
& Delay
5
6
Current
Rating
7
Terminal
1 B B
8
Actuator
Color
M
Paddle
TPush-Pull
3 POLES
2Two
4 CIRCUIT/AUXILIARY SWITCH1
P Series Trip Current (Parallel Pole)
with Auxiliary Switch, Silver Contacts
Q Series Trip Current (Parallel Pole)
with Auxiliary Switch, Gold Contacts
R Series Trip Current (Parallel Pole)
.110 x 0.20 Q.C
.110 x 0.20 Q.C
5 FREQUENCY & TIME DELAY
11
Brushing
Color
DC Short
DC Medium
10 LEGEND PLATE / BUTTON MARKING
Handle Actuator Legend Plate
B
ON - OFF Vertical
C
ON - OFF Horizontal
Push-Pull Actuator Legend Plate
2
Rated Amps Horizontal
3
Rated Amps Line Side Down
4
Rated Amps Line Side Up
6 CURRENT RATING (AMPERES)
11 BUSHING COLOR
631
635
640
645
650
12 AGENCY APPROVAL
B
AMPERES
31.000
35.000
40.000
45.000
50.000
T
Push in Stud
10-32 Screw (Bus Type)
8 ACTUATOR COLOR & LEGEND
Handle
1
White 2 Black
3 Red
4 Green
5 Blue
6 Yellow
7 Gray
8 Orange
Black
UL 489A Listed
Notes:
1 Aux Switch only available with screw terminals
7 TERMINAL
A
5
10
Legend
Plate/
Marking
Handle
A
No outer Panel Hardware
B
Knurled Nut, Bright Nickel
C
Knurled Nut, Bright Nickel w/Locking Ring
D
Knurled Nut, Black
E
Knurled Nut, Black w/Locking Ring
F
Panel Dress, Bright Nickel
G
Panel Dress, Bright Nickel w/Locking Ring
H
Panel Dress, Black
J
Panel Dress, Black w/Locking Ring
Push Button
1
No outer Panel Hardware
2
Knurled Nut, Bright Nickel
2 ACTUATOR
CODE
9
Front
Panel
Hardware
B
9 FRONT PANEL HARDWARE
1 SERIES
M
D2 D4 650
Push Button
A
White
BBlack
CRed
DGreen
EBlue
FYellow
GGray
HOrange
60 Johnson Avenue • Plainville, CT 06062 • Phone: (860) 793–9281 • Fax: (860) 793–9231
Email: [email protected] • www.carlingtech.com
T
12
Agency
Approval
M-Series Parallel Pole - Form & Fit Drawings | 7
PARALLEL POLE TERMINAL OPTIONS
PUSH-IN STUD
10-32 SCREW W/ BUS BAR
.652 [16.56]
.912 [23.16]
1.000 [25.4]
.838 [21.29]
.154 [3.91]
.393 [9.97]
1.125 [28.58]
1.000 [25.4]
.100 [2.54]
.750 [19.05]
ROCKER ACTUATOR DETAIL
INDICATE "ON" (VISI-ON)
.370 [9.40] MAX.
±.020
1.394 [35.41]
[±.508]
±.020
1.530 [38.86]
[±.508]
1.304 [33.12]
LINE
OFF
.970 [24.64]
1.375 [34.93]
1.560 [39.62]
1.125 [28.58]
ON
LOAD
.400 [10.16]
.625 [15.88]
.100 [2.54]
ROCKERGUARD CONFIGURATION
INDICATE "OFF" (VISI-OFF)
& SINGLE COLOR
±.020
±.020
±.508
±.508
.305 [7.75]
.675 [17.14]
LOAD
ON
LOAD
ON
OFF
LINE
±.020
±.508
1.050 [26.67]
OFF
LINE
PANEL CUT - OUT DETAIL (ROCKER)
DOUBLE POLE
PANEL
THICKNESS
DIM. A
±.005
±.13
1.139 [33.76]
DIM. A
+.005 +.13
-.000 -.00
.062 [1.57]
1.385 [35.18]
.093 [2.36]
1.420 [36.07]
.125 [3.18]
1.460 [37.08]
Notes:
1 ALL DIMENSIONS ARE IN INCHES [MILLIMETERS].
2 TOLERANCE ±.010 [.25] UNLESS OTHERWISE SPECIFIED.
3 DIMENSIONS APPLY TO BOTH ROCKER STYLES.
4 I-O, ON-OFF OR DUAL LEGENDS AVAILABLE FOR VERTICAL OR HORIZONTAL MOUNTING.
5 NOTICE THAT CIRCUIT BREAKER LINE AND LOAD TERMINAL ORIENTATION ON INDICATE “OFF” IS OPPOSITE THAT OF INDICATE “ON”.
60 Johnson Avenue • Plainville, CT 06062 • Phone: (860) 793–9281 • Fax: (860) 793–9231
Email: [email protected] • www.carlingtech.com
NOTE
1. A
2. T
3. D
4. IV
5. N
O
IN
8 | M-Series Parallel Pole - Form & Fit Drawings
PADDLE ACTUATOR STYLE
PUSH-PULL ACTUATOR STYLE
1.484
1.395
1/2-32 THD.
3/8" 8-32 THD.
12°
ON
OFF
FLAT
12°
FLAT
±.030
+.010
-.000
+.25
-.000
+.25
-.000
.500 DIA [Ø12.70]
+.010
-.000
±.002 ±.05
+.010
-.000
±.005 [±.13]
+.25
-.000
.125 DIA [Ø3.18]
WITH LOCKING RING
WITHOUT LOCKING RING
.625 [15.87] DIA
.494
[12.55]
+.25
-.00
.544[13.82]
.156
[3.56]
.534
[13.56]
SNAP-IN BUSHING
.078
[1.98]
.435 [11.05] DIA
PANEL DRESS NUT
0N
1.025 [26.04]
O
F
F
O
N
BUTTON MARKING ORIENTATION
0FF
LEGEND
CODE:
.098
[2.49]
HEX NUT
.632 DIA [Ø16.05]
.340 [8.64]
±.76
PANEL HARDWARE
PUSH-PULL,
PUSH TO RESET
±.002 [±.050]
.222 [5.64]
LEGEND PLATES
.025 [.64]
±.030
.375 [9.53]
DIA
.162 [4.11]
.355 [9.02]
.400 [10.16]
MOUNTING DETAILS
MOUNTING DETAILS
+.010
-.000
±.76
±.76
.280 [7.11] ON
.500 [12.70]
.500 DIA [Ø12.70]
±.030
±.030
.500 [12.70] OFF (SHOWN)
.470 [11.94]
±.76
ACTUATOR COLOR
VISIBLE IN OFF
POSITION ONLY
B
LINE
C
LINE
PANEL HARDWARE
.625 [15.88]
.680 DIA [Ø17.27]
.125 [3.18]
.180 [4.57]
20
20
20
3
4
LINE
MARKING
CODE:
2
NOTES:
.110QC AUXILIARY SWITCH1.
TERMINALS
ALL DIMENSIONS
PANEL DRESS NUT
HEX NUT
.680 DIA [Ø17.27]
.125 [3.18]
.105 [2.67]
.031 [.79]
.683 DIA [Ø17.27]
KNURLED NUT
.342 [8.69]
ARE I
2. TOLERANCE ±.010 [.25]
3. DIMENSIONS APPLY TO
4. I-O, ON-OFF OR DUAL L
VERTICAL OR HORIZON
5. NOTICE THAT CIRCUIT
ORIENTATION ON INDIC
INDICATE "ON".
LOCKING RING
Notes:
1 ALL DIMENSIONS ARE IN INCHES [MILLIMETERS].
2 TOLERANCE ±.010 [.25] UNLESS OTHERWISE SPECIFIED.
3 DIMENSIONS APPLY TO BOTH ROCKER STYLES.
4 I-O, ON-OFF OR DUAL LEGENDS AVAILABLE FOR VERTICAL OR HORIZONTAL MOUNTING.
5 NOTICE THAT CIRCUIT BREAKER LINE AND LOAD TERMINAL ORIENTATION ON INDICATE “OFF” IS OPPOSITE THAT OF INDICATE “ON”.
60 Johnson Avenue • Plainville, CT 06062 • Phone: (860) 793–9281 • Fax: (860) 793–9231
Email: [email protected] • www.carlingtech.com
TITLE
DR BY
ME
5/10/12
M-Series Handle/Pushbutton UL Recognized - Ordering Scheme | 9
M M 1
1
Series
2
Actuator
B
34
4
Circuit
3
Poles
5
Frequency
& Delay
260
6
Current
Rating
CODE
1
Handle
M
Paddle
NBaton
Push Button
TPush-Pull
U
Push To Reset
Push Button w/ Snap-In Mounting
VPush-Pull
W
Push To Reset
3 POLES
1
One
2Two
C
9
10
Front Panel Legend
Hardware Plate
020
025
030
035
040
045
050
055
060
065
070
075
080
085
090
090
210
215
220
AMPERES
0.020
0.025
0.030
0.035
0.040
0.045
0.050
0.055
0.060
0.065
0.070
0.075
0.080
0.085
0.090
0.095
0.100
0.150
0.200
225
230
235
240
245
250
255
260
265
270
275
280
285
290
295
410
512
415
517
0.250
0.300
0.350
0.400
0.450
0.500
0.550
0.600
0.650
0.700
0.750
0.800
0.850
0.900
0.950
1.000
1.250
1.500
1.750
B
11
Bushing
Color
420 2.000
522 2.250
425 2.500
527 2.750
430 3.000
435 3.500
440 4.000
445 4.500
450 5.000
455 5.500
460 6.000
465 6.500
470 7.000
475 7.500
480 8.000
485 8.500
490 9.000
495 9.500
610 10.000
7 TERMINAL8
4 CIRCUIT2
without Auxiliary Switch
A
Switch Only (no coil) , Maintained Contacts
B
Series Trip (Current)
with Auxiliary Switch, Silver Contacts Terminal Type:
M
Series Trip (Current) Aux Switch
.110 QC x .020 QC
3
P Switch Only, Maintained Contacts .060 Dia, Round Solder Turret
3,4
Q Switch Only, Maintained Contacts .058 Dia, Round Q.C.
R3,13 Switch Only, Maintained Contacts .080 Dia x .020 Flat Q.C.
S3 Series Trip (Current)
.060 Dia, Round Solder Turret
3,4
T Series Trip (Current)
.058 Dia, Round Q.C.
3,13
U
Series Trip, Maintained Contacts
.080 Dia x .020 Flat Q.C.
with Auxiliary Switch, Gold Contacts 23,4 Switch Only, Maintained Contacts .058 Dia, Round Q.C.
33,13 Switch Only, Maintained Contacts .080 Dia x .020 Flat Q.C.
3,4
4 Series Trip (Current)
.058 Dia, Round Q.C.
53,13 Series Trip, Maintained Contacts
.080 Dia x .020 Flat Q.C.
9
Series Trip (Current) Aux Switch
.110 QC x .020 QC
5 FREQUENCY & DELAY
03 10 12
14
20
22
24 30 1 B B
8
Actuator
Color
12
Agency
Approval
6 CURRENT RATING (AMPERES) 8
1 SERIES
M
2 ACTUATOR
1
7
Terminal
DC 50/60Hz, Switch Only
DC Instantaneous
DC Short
DC Medium
50/60Hz Instantaneous
50/60Hz Short
50/60Hz Medium
DC, 50/60Hz Instantaneous
32
DC, 50/60Hz Short
34
DC, 50/60Hz Medium
62 50/60Hz Short, Hi-Inrush
64 50/60Hz Medium, Hi-Inrush
72 DC, Short,Hi-Inrush
74 DC,Medium, Hi-Inrush
92
DC, 50/60Hz Short, Hi-Inrush
94
DC, 50/60Hz Medium,
Hi-Inrush
1
210
310
Push-On 0.250 Tab (Q.C.)
Screw 8-32 w/upturned lugs
Screw 8-32 (Bus Type)
A11
P12
8 ACTUATOR COLOR & LEGEND5
Gloss Handle
Push-Button
1A
2B
3C
4D
5E
6F
8H
9 FRONT PANEL HARDWARE6
Handle No outer Panel Hardware
A
Knurled Nut
Bright nickel
B
Bright nickel with locking ring
C
Black
D
Black with locking ring
E
Panel Dress Nut
Bright nickel F
Bright nickel with locking ring
G
Black H
Black with locking ring
J
Actuator Color
White
Black
Red
Green
Blue
Yellow
Orange
Push-Button
1
2
Handle Actuator Legend Plate (Actuator Styles M & N)
A
No Legend Plate
B
ON - OFF Vertical
C
ON - OFF Horizontal
D
I - O Vertical
E
I - O Horizontal
Push-Pull Actuator Button Cap (Actuator Styles T & V)
1
No Marking
2
Rated Amps Horizontal
3
Rated Amps Line Side Down
4
Rated Amps Line Side Up
Push-to-Reset Actuator Button (Actuator Styles U& W)
1
No Marking
11 BUSHING COLOR7
B
Black
12 AGENCY APPROVAL9
C
D
E
10.500
11.000
11.500
12.000
12.500
13.000
14.000
15.000
16.000
17.000
18.000
20.000
22.000
24.000
25.000
30.000
Push-In Stud
Printed Circuit Board
10 LEGEND PLATE / BUTTON MARKING
Notes:
1 One actuator is located in the center of each multi-pole breaker. Actuator codes V & W limited to single pole breakers only.
2 Switch Only circuits are not available with Push-To-Reset actuators. For Switch Only circuits, select Current Coil Rating from the above chart:
3 One Auxiliary Switch is supplied per breaker. On two-pole breakers, standard Auxiliary Switch mounting is in pole one. Auxiliary Switch option limited to Series Trip and Switch Only circuits. Not available with back connect screw or push-in stud terminals.
4 Mates with AMP .058” diameter pin receptacles including 60983-1 (gold plated)
and 60983-2 (tin plated).
5 Actuator color is only visible in the OFF position on Push-Pull actuators.
6 All units except snap-in mounting have one hex nut installed on bushing for use behind
the panel.
7 Other colors available. Consult factory.
8 TUV and VDE Certification above 15 amps is for 2-pole only and is limited to a max. of
20 amps. Screw Terminal or Push-In Stud recommended above 20 amps.
9 30 amp rating not available with delay’s 30, 32, 34, 92 or 94.
10 Screw Terminals are VDE certified only with use of ring terminal attached to wire.
11 Terminal code A available with circuit codes A & B only.
12 Printed circuit board available with UL recognized approval only.
13 Auxiliary switch (flat Q.C.) available with UL recognized approvals only.
710
611
711
612
712
613
614
615
616
617
618
620
622
624
625
630
UL Recognized & CSA Accepted
VDE Certified, UL Recognized & CSA Accepted
TUV Certified, UL Recognized & CSA Accepted
60 Johnson Avenue • Plainville, CT 06062 • Phone: (860) 793–9281 • Fax: (860) 793–9231
Email: [email protected] • www.carlingtech.com
10 | M-Series Handle/Pushbutton UL489A/UL Recognized – Ordering Scheme
M M 1
1
Series
2
Actuator
B 14
4
Circuit
3
Poles
620
5
Frequency
& Delay
6
Current
Rating
1
7
Terminal
1 B B
8
Actuator
Color
7 TERMINAL4
1 SERIES
M
1
2
3
2 ACTUATOR1
Handle
M
Paddle
NBaton
Push Button
TPush-Pull
U8
Push To Reset
Push Button w/ Snap-In Mounting
VPush-Pull
W8
Push To Reset
Push-On 0.250 Tab (Q.C.)
Screw 8-32 w/upturned lugs
Screw 8-32 (Bus Type)
Gloss Handle
Push-Button
1A
2B
3C
4D
5E
6F
8H
9 FRONT PANEL HARDWARE6
1
One
4 CIRCUIT
without Auxiliary Switch
B
Series Trip (Current)
with Auxiliary Switch, Silver Contacts Terminal Type:
M
Series Trip (Current) Aux Switch
.110 QC x .020 QC
S2 Series Trip (Current)
.060 Dia, Round Solder Turret
T2,3 Series Trip (Current)
.058 Dia, Round Q.C.
U3,12 Series Trip, Maintained Contacts
.080 Dia x .020 Flat Q.C.
with Auxiliary Switch, Gold Contacts 42,3 Series Trip (Current)
.058 Dia, Round Q.C.
53,12 Series Trip, Maintained Contacts
.080 Dia x .020 Flat Q.C.
9
Series Trip (Current) Aux Switch
.110 QC x .020 QC
5 FREQUENCY & DELAY
10 12
DC Instantaneous
DC Short
14
72 74 DC Medium
DC, Short,Hi-Inrush
DC,Medium, Hi-Inrush
6 CURRENT RATING (AMPERES)
CODE
020
025
030
035
040
045
050
055
060
065
070
075
080
085
090
090
210
215
220
AMPERES
0.020
0.025
0.030
0.035
0.040
0.045
0.050
0.055
0.060
0.065
0.070
0.075
0.080
0.085
0.090
0.095
0.100
0.150
0.200
225
230
235
240
245
250
255
260
265
270
275
280
285
290
295
410
512
415
517
0.250
0.300
0.350
0.400
0.450
0.500
0.550
0.600
0.650
0.700
0.750
0.800
0.850
0.900
0.950
1.000
1.250
1.500
1.750
420 2.000
522 2.250
425 2.500
527 2.750
430 3.000
435 3.500
440 4.000
445 4.500
450 5.000
455 5.500
460 6.000
465 6.500
470 7.000
475 7.500
480 8.000
485 8.500
490 9.000
495 9.500
610 10.000
710
611
711
612
712
613
614
615
616
617
618
620
622
624
625
630
10.500
11.000
11.500
12.000
12.500
13.000
14.000
15.000
16.000
17.000
18.000
20.000
22.000
24.000
25.000
30.000
11
Bushing
Color
A10
P11
8 ACTUATOR COLOR & LEGEND5
3 POLES
B
9
10
Front Panel Legend
Hardware Plate
Handle No outer Panel Hardware
A
Knurled Nut
Bright nickel
B
Bright nickel with locking ring
C
Black
D
Black with locking ring
E
Panel Dress Nut
Bright nickel F
Bright nickel with locking ring
G
Black H
Black with locking ring
J
Push-In Stud
Printed Circuit Board
Actuator Color
White
Black
Red
Green
Blue
Yellow
Orange
Push-Button
1
2
10 LEGEND PLATE / BUTTON MARKING
Handle Actuator Legend Plate (Actuator Styles M & N)
A
No Legend Plate
B
ON - OFF Vertical
C
ON - OFF Horizontal
D
I - O Vertical
E
I - O Horizontal
Push-Pull Actuator Button Cap (Actuator Styles T & V)
18
No Marking
2
Rated Amps Horizontal
3
Rated Amps Line Side Down
4
Rated Amps Line Side Up
Push-to-Reset Actuator Button (Actuator Styles U& W)
18
No Marking
11 BUSHING COLOR7
B
Black
12 AGENCY APPROVAL9
J
M
N
T
UL489A Listed, TUV Certified
UL Recognized, CSA Accepted
UL Recognized, TUV Certified
UL489A Listed
Notes:
1 One actuator is located in the center of each multi-pole breaker. Actuator codes V & W limited to single pole breakers only.
2 One Auxiliary Switch is supplied per breaker. On two-pole breakers, standard Auxiliary Switch mounting is in pole one. Auxiliary Switch option limited to Series Trip and Switch Only circuits.
Not available with Back Connected Screw or Push-in Stud terminals.
3 Mates with AMP .058” diameter pin receptacles including 60983-1 (gold plated) and
60983-3 (tin plated).
4 Screw terminals or Push-in Stud recommended above 20 amps.
5 Actuator color is only visible in the OFF position on Push-Pull actuators.
6 All units have one hex nut installed on bushing for use behind the panel.
7 Other colors available. Consult factory.
8 Not available with UL489A Listed breakers.
9 TUV certified to 25 amps. UL Recognized, CSA Accepted and UL Listed to 30 amps.
10 Terminal code A available with circuit codes A & B only.
11 Printed circuit board available with UL recognized approval only.
12 Auxiliary switch (flat Q.C.) available with UL recognized approvals only.
60 Johnson Avenue • Plainville, CT 06062 • Phone: (860) 793–9281 • Fax: (860) 793–9231
Email: [email protected] • www.carlingtech.com
J
12
Agency
Approval
M-Series Handle – Circuit & Terminal Diagrams | 11
Notes:
1 All dimensions are in inches [millimeters].
2 Tolerance ±.020 [.51] unless otherwise specified.
60 Johnson Avenue • Plainville, CT 06062 • Phone: (860) 793–9281 • Fax: (860) 793–9231
Email: [email protected] • www.carlingtech.com
12 | M-Series Handle – PC Terminal Diagrams
Notes:
1 All dimensions are in inches [millimeters].
2 Tolerance ±.020 [.51] unless otherwise specified.
60 Johnson Avenue • Plainville, CT 06062 • Phone: (860) 793–9281 • Fax: (860) 793–9231
Email: [email protected] • www.carlingtech.com
M-Series Handle - Form & Fit Drawings | 13
Notes:
1 All dimensions are in inches [millimeters].
2 Tolerance ±.020 [.51] unless otherwise specified.
60 Johnson Avenue • Plainville, CT 06062 • Phone: (860) 793–9281 • Fax: (860) 793–9231
Email: [email protected] • www.carlingtech.com
14 | M-Series Pushbutton – Circuit & Terminal Diagrams
Notes:
1 All dimensions are in inches [millimeters].
2 Tolerance ±.020 [.51] unless otherwise specified.
60 Johnson Avenue • Plainville, CT 06062 • Phone: (860) 793–9281 • Fax: (860) 793–9231
Email: [email protected] • www.carlingtech.com
M-Series Pushbutton – Form & Fit Drawings | 15
Notes:
1 All dimensions are in inches [millimeters].
2 Tolerance ± 0.20 [.51] unless otherwise specified.
3 Available with Push-Pull or Push-to-Reset Actuators
60 Johnson Avenue • Plainville, CT 06062 • Phone: (860) 793–9281 • Fax: (860) 793–9231
Email: [email protected] • www.carlingtech.com
16 | M-Series Push-Pull – PC Terminal Drawings
Notes:
1 All dimensions are in inches [millimeters].
2 Tolerance ±.020 [.51] unless otherwise specified.
60 Johnson Avenue • Plainville, CT 06062 • Phone: (860) 793–9281 • Fax: (860) 793–9231
Email: [email protected] • www.carlingtech.com
M-Series Rocker UL Recognized – Ordering Scheme | 17
M G 2
1
Series
2
Actuator
B 34
4
Circuit
3
Poles
5
Frequency
& Delay
620
6
Current Rating
9
8
Illumination Actuator
Color
7
Terminal
CODE
2 ACTUATOR1
Non-Illuminated
single color
A
Angled
B
Flat
Two Color
Visi-Rocker
D
Indicate ON
E
Indicate OFF
3 POLES
One
illuminated
single color
F
Angled
G
Flat
2Two
020
025
030
035
040
045
050
055
060
065
070
075
080
085
090
090
210
215
220
AMPERES
0.020
0.025
0.030
0.035
0.040
0.045
0.050
0.055
0.060
0.065
0.070
0.075
0.080
0.085
0.090
0.095
0.100
0.150
0.200
225
230
235
240
245
250
255
260
265
270
275
280
285
290
295
410
512
415
517
0.250
0.300
0.350
0.400
0.450
0.500
0.550
0.600
0.650
0.700
0.750
0.800
0.850
0.900
0.950
1.000
1.250
1.500
1.750
7 TERMINAL
4 CIRCUIT2
without Auxiliary Switch
A
Switch Only (no coil) , Maintained Contacts
B
Series Trip (Current)
with Auxiliary Switch, Silver Contacts Terminal Type:
M
Series Trip (Current) Aux Switch
.110 QC x .020 QC
P3 Switch Only, Maintained Contacts .060 Dia, Round Solder Turret
Q3,4 Switch Only, Maintained Contacts .058 Dia, Round Q.C.
R3,16 Switch Only, Maintained Contacts .080 Dia x .020 Flat Q.C.
S3 Series Trip (Current)
.060 Dia, Round Solder Turret
T3,4 Series Trip (Current)
.058 Dia, Round Q.C.
U3,16 Series Trip, Maintained Contacts
.080 Dia x .020 Flat Q.C.
with Auxiliary Switch, Gold Contacts 23,4 Switch Only, Maintained Contacts .058 Dia, Round Q.C.
33,16 Switch Only, Maintained Contacts .080 Dia x .020 Flat Q.C.
43,4 Series Trip (Current)
.058 Dia, Round Q.C.
53,16 Series Trip, Maintained Contacts
.080 Dia x .020 Flat Q.C.
9
Series Trip (Current) Aux Switch
.110 QC x .020 QC
5 FREQUENCY & DELAY
03 10 12
14
20
22
24 30 H C 6
7
10
Legend
C
11
Bezel Color
12
Agency
Approval
6 CURRENT RATING (AMPERES)
1 SERIES
M
1
1
DC 50/60Hz, Switch Only
DC Instantaneous
DC Short
DC Medium
50/60Hz Instantaneous
50/60Hz Short
50/60Hz Medium
DC, 50/60Hz Instantaneous
32
34
62 64 72 74 92
94
DC, 50/60Hz Short
DC, 50/60Hz Medium
50/60Hz Short, Hi-Inrush
50/60Hz Medium, Hi-Inrush
DC, Short,Hi-Inrush
DC,Medium, Hi-Inrush
DC, 50/60Hz Short, Hi-Inrush
DC, 50/60Hz Medium,
Hi-Inrush
Notes:
1 One actuator is located in the center of each multi-pole breaker.
2 For Switch Only circuits, select Current Coil Rating from the above chart:
3 One Auxiliary Switch is supplied per breaker. On two-pole breakers, standard Auxiliary Switch mounting is in pole one. Auxiliary Switch option limited to Series Trip & Switch Only circuits, & is not available in single pole illuminated breakers, or Back Connected Screw or Push-in Stud terminals.
4 Mates with AMP .058” diameter pin receptacles: 60983-1 (gold plated) & 60983-2
(tin plated).
5 For neon bulb applications at 120VAC @ 47K, 1/4 WATT and for 250VAC applications @ 150K, 1/4 WATT, external resistors must be supplied by customer.
6 On Visi-Rocker breakers, Visi portion of rocker cannot be the same color as the bezel.
7 For LED (DC or rectified AC) applications, LED is mounted in the center of the rocker
actuator with electrical characteristics: 100 millicandela at 20mA; Maximum power
dissipation = 75mW at 25°C; Maximum forward current = 25mA; Typical forward voltage = 2.1V at 20mA; Typical reverse current = 100uA at 3V. Customer supplies the proper external resistor limiting current to these values.
8 Rocker color for LED’s and green neon lamp must be clear, smoke gray, white translucent or match color of LED or neon lamp.
9 Other colors available. Consult factory.
10 TUV 20A, VDE 15A. UL Recognized and CSA Accepted to 30 amps. Screw Terminals or Push-in Stud recommended above 20 amps.
11 TUV or VDE Certified must have I-O or Dual Legends. Legend required on Visi-Rocker breakers.
12 30 amp rating not available with delay’s 30, 32, 34, 92 or 94.
13 Screw Terminals are VDE certified only with use of ring terminal attached to wire.
14 Terminal code A available with circuit codes A & B only.
15 Printed circuit board available with UL recognized approval only.
16 Auxiliary switch (flat Q.C.) available with UL recognized approvals only.
1
210
310
Push-On 0.250 Tab (Q.C.)
Screw 8-32 w/upturned lugs
Screw 8-32 (Bus Type)
8 ROCKER ILLUMINATION
Non-illuminated Neon5 without resistor, 120VAC/250VAC LED7, 8 without resistor with resistor, 4-8 VDC with resistor, 9-16 VDC 420 2.000
522 2.250
425 2.500
527 2.750
430 3.000
435 3.500
440 4.000
445 4.500
450 5.000
455 5.500
460 6.000
465 6.500
470 7.000
475 7.500
480 8.000
485 8.500
490 9.000
495 9.500
610 10.000
A14
P15
A
Neon B
Red D
E
F
710 10.500
611 11.000
711 11.500
612 12.000
712 12.500
613 13.000
614 14.000
615 15.000
616 16.000
617 17.000
618 18.000
620 20.000
622 22.000
624 24.000
625 25.000
63012 30.000
Push-In Stud
Printed Circuit Board
Green Glow8
C
Green G
H
J
Amber
K
L
M
9 ACTUATOR & LEGEND COLOR
Solid Color 1
2
3
4
5
6
7
8
Visi-Rocker6 1
2
3
4
5
6
7
8
Illuminated8 A
B
C
D
E
F
Actuator Legend
White Black
Black White
Red White
Green White
Blue White
Yellow Black
Gray Black
Orange Black
Visi & Legend (remainder of rocker same color as bezel)
White
Black
Red
Green
Blue
Yellow
Gray
Orange
Actuator Legend
Clear White
Red Transparent White
Green Transparent White
Amber Transparent White
Smoke Gray Transparent White
White Translucent Black
10 LEGEND11
1
2
3
No Legend
ON - OFF Vertical
ON - OFF Horizontal
4
5
6
7
I - O Vertical
I - O Horizontal
Dual Vertical
Dual Horizontal
11 BEZEL COLOR / STYLE9
Color
White
Black
Gray
without Rockerguard
with Rockerguard
A1
B2
G7
12 AGENCY APPROVAL10
C
D
E
UL Recognized & CSA Accepted
VDE Certified, UL Recognized & CSA Accepted
TUV Certified, UL Recognized & CSA Accepted
60 Johnson Avenue • Plainville, CT 06062 • Phone: (860) 793–9281 • Fax: (860) 793–9231
Email: [email protected] • www.carlingtech.com
18 | M-Series Rocker UL489A/UL Recognized – Ordering Scheme
M A 1
1
Series
2
Actuator
B 14
4
Circuit
3
Poles
5
Frequency
& Delay
620
6
Current Rating
1
A 1 6
9
8
Illumination Actuator
Color
7
Terminal
7 TERMINAL9
1 SERIES
M
1
2
3
2 ACTUATOR1
Non-Illuminated
single color
A
Angled
B
Flat
Two Color
Visi-Rocker
D
Indicate ON
E
Indicate OFF
llluminated
single color
F
Angled
G
Flat
Push-On 0.250 Tab (Q.C.)
Screw 8-32 w/upturned lugs
Screw 8-32 (Bus Type)
8 ILLUMINATION
Non-illuminated Neon4 without resistor, 120VAC/250VAC LED7, 8 without resistor with resistor, 4-8 VDC with resistor, 9-16 VDC 2
10
Legend
A11
P12
A
Neon B
Red D
E
F
J
11
Bezel Color
12
Agency
Approval
Push-In Stud
Printed Circuit Board
Green Glow8
C
Green G
H
J
Amber
K
L
M
9 ACTUATOR & LEGEND COLOR
3 POLES
1
One
4 CIRCUIT2
without Auxiliary Switch
B
Series Trip (Current)
with Auxiliary Switch, Silver Contacts Terminal Type:
M
Series Trip (Current) Aux Switch
.110 QC x .020 QC
S
Series Trip (Current)
.060 Dia, Round Solder Turret
T3 Series Trip (Current)
.058 Dia, Round Q.C.
3,13
U
Series Trip, Maintained Contacts
.080 Dia x .020 Flat Q.C.
with Auxiliary Switch, Gold Contacts 43 Series Trip (Current)
.058 Dia, Round Q.C.
53,13 Series Trip, Maintained Contacts
.080 Dia x .020 Flat Q.C.
9
Series Trip (Current) Aux Switch
.110 QC x .020 QC
5 FREQUENCY & DELAY
10 12
DC Instantaneous
DC Short
14
72 74 DC Medium
DC, Short,Hi-Inrush
DC,Medium, Hi-Inrush
6 CURRENT RATING (AMPERES) 8
CODE
020
025
030
035
040
045
050
055
060
065
070
075
080
085
090
090
210
215
220
AMPERES
0.020
0.025
0.030
0.035
0.040
0.045
0.050
0.055
0.060
0.065
0.070
0.075
0.080
0.085
0.090
0.095
0.100
0.150
0.200
225
230
235
240
245
250
255
260
265
270
275
280
285
290
295
410
512
415
517
0.250
0.300
0.350
0.400
0.450
0.500
0.550
0.600
0.650
0.700
0.750
0.800
0.850
0.900
0.950
1.000
1.250
1.500
1.750
420 2.000
522 2.250
425 2.500
527 2.750
430 3.000
435 3.500
440 4.000
445 4.500
450 5.000
455 5.500
460 6.000
465 6.500
470 7.000
475 7.500
480 8.000
485 8.500
490 9.000
495 9.500
610 10.000
710
611
711
612
712
613
614
615
616
617
618
620
622
624
625
630
10.500
11.000
11.500
12.000
12.500
13.000
14.000
15.000
16.000
17.000
18.000
20.000
22.000
24.000
25.000
30.000
Notes:
1 One actuator is located in the center of each multi-pole breaker.
2 One Auxiliary Switch is supplied per breaker. Auxiliary Switch option limited to Series Trip & Switch Only circuits, and is not available in single pole illuminated breakers, or with Back Connected Screw or Push-in Stud terminals.
3 Mates with AMP .058” diameter pin receptacles: 60983-1 (gold plated) & 60983-1
(tin plated).
4 For neon bulb applications at 120VAC @ 47K, 1/4 WATT and for 250VAC applications @ 150K, 1/4 WATT, external resistors must be supplied by customer.
5 For LED (DC or rectified AC) applications, LED is mounted in the center of the rocker actuator with electrical characteristics as follows: 100 millicandela at 20mA; Maximum power dissipation = 75mW at 25°C; Maximum forward current = 25mA; Typical forward voltage = 2.1V at 20mA; Typical reverse current = 100uA at 3V. Customer supplies the proper external resistor limiting current to these values.
6 On Visi-Rocker breakers, Visi portion of rocker cannot be the same color as the bezel.
7 Rocker color for LED’s and green neon lamp must be clear, smoke gray, white translucent or
match color of LED or neon lamp.
8 Other colors available. Consult factory.
9 TUV Certified to 25 amps. UL Recognized, CSA Accepted and UL489A Listed to 30 amps.
Screw Terminals recommended above 20 amps.
10 UL489A Listed must have ON-OFF or Dual legends. TUV Certified approvals must have
I - O or Dual legends.
11 Terminal code A available with circuit codes A & B only.
12 Printed circuit board available with UL recognized approval only.
13 Auxiliary switch (flat Q.C.) available with UL recognized approvals only.
Solid Color Actuator Legend
1
White Black
2
Black White
3
Red White
4
Green White
5
Blue White
6
Yellow Black
7
Gray Black
8
Orange Black
Visi-Rocker6 Visi & Legend (remainder of rocker same color as bezel)
1
White
2
Black
3
Red
4
Green
5
Blue
6 Yellow
7
Gray
8
Orange
Illuminated7 Actuator Legend
A
Clear White
B
Red Transparent White
C
Green Transparent White
D
Amber Transparent White
E
Smoke Gray Transparent White
F
White Translucent Black
10 LEGEND10
1
2
3
4
5
6
7
No Legend (Single Color or Illuminated Rocker Options Only)
ON - OFF Vertical
ON - OFF Horizontal
I - O Vertical
I - O Horizontal
Dual Vertical
Dual Horizontal
11 BEZEL COLOR / STYLE8
Color
White
Black
Gray
without Rockerguard
with Rockerguard
A1
B2
G7
12 AGENCY APPROVAL9
J
M
N
T
UL489A Listed & TUV Certified
UL Recognized & CSA Accepted
TUV Certified, UL Recognized & CSA Accepted
UL489A Listed
60 Johnson Avenue • Plainville, CT 06062 • Phone: (860) 793–9281 • Fax: (860) 793–9231
Email: [email protected] • www.carlingtech.com
M-Series Rocker – Circuit & Terminal Diagrams | 19
Notes:
1 All dimensions are in inches [millimeters].
2 Tolerance ±.020 [.51] unless otherwise specified.
3 Schematic shown represents current trip circuit.
60 Johnson Avenue • Plainville, CT 06062 • Phone: (860) 793–9281 • Fax: (860) 793–9231
Email: [email protected] • www.carlingtech.com
20 | M-Series Rocker – Form & Fit Drawings
Notes:
1 Dimensions apply to all variations shown. Notice that circuit breaker line & load terminal orientation on indicate OFF is opposite of indicate ON.
2 I-O, ON-OFF or dual legends available for vertical or horizontal mounting. For pole orientation with horizontal legend, rotate front view clockwise 90°.
3 All dimensions are in inches [millimeters].
4 Tolerance ± 0.20 [.51] unless otherwise specified.
60 Johnson Avenue • Plainville, CT 06062 • Phone: (860) 793–9281 • Fax: (860) 793–9231
Email: [email protected] • www.carlingtech.com
M-Series Rocker – Supplementary Diagrams | 21
60 Johnson Avenue • Plainville, CT 06062 • Phone: (860) 793–9281 • Fax: (860) 793–9231
Email: [email protected] • www.carlingtech.com
22 | M-Series Circuit Breaker - Time Delay Curve
Notes:
1 Delay Curves 12,14, 22, 24, 32, 34, 62, 64, 72, 74, 92, 94: Breakers to hold 100% and must trip at 135% of rated current and greater within the time limit shown in this curve.
2 Delay Curves 10, 20, 30: Breakers to hold 100% and must trip at 150% of rated current and greater within the time limit shown in this curve.
3 All Curves: Curve data shown represents breaker response at ambient temperature of 77°F (25°C) with no preloading. Breakers are mounted in standard wall-mount position.
4 The minimum inrush pulse tolerance handling capability is 12 times the rated current on standard delays and 18 times the rated current on high inrush delays. These values are based on a 60 Hz 1/2 cycle,
8.33 ms pulse. High inrush delays should be specified for applications with high initial surge currents of short duration, such as switching power supplies, highly capacitive loads and transformer loads.
Dual Rated AC/DC
Instantaneous
Short
Short D2
Medium
Medium D4
60 Johnson Avenue • Plainville, CT 06062 • Phone: (860) 793–9281 • Fax: (860) 793–9231
Email: [email protected] • www.carlingtech.com
Notes | 23
* Intentionally left blank
60 Johnson Avenue • Plainville, CT 06062 • Phone: (860) 793–9281 • Fax: (860) 793–9231
Email: [email protected] • www.carlingtech.com
Worldwide Headquarters
Carling Technologies, Inc.
60 Johnson Avenue • Plainville, CT 06062
Phone: (860) 793-9281 • Fax: (860) 793-9231
Email: [email protected] • www.carlingtech.com
East Region Sales Office, CT • [email protected]
Midwest Region Sales Office, IL • [email protected]
West Region Sales Office, CA • [email protected]
Asia-Pacific Headquarters
Carling Technologies, Asia-Pacific Ltd.,
Kowloon, Hong Kong
Int + 852-2737-2277 • Fax: Int + 852-2736-9332
Email: [email protected]
Shenzhen, China • [email protected]
Shanghai, China • [email protected]
Pune, India • [email protected]
Kaohsiung, Taiwan • [email protected]
Yokohama, Japan • [email protected]
Europe/Middle East/Africa Headquarters
Carling Technologies LTD
4 Airport Business Park, Exeter Airport,
Clyst Honiton, Exeter, Devon, EX5 2UL, UK
Int + 44 1392-364422 • Fax: Int + 44 1392-364477
Email: [email protected]
GmbH, Germany • [email protected]
SAS, France • [email protected]
REV_CB_M_07_2014