F9000_PCR314

PCR314
Patent Pending
High Power factor State of
the art dual Current
Regulator for up to 6,6Amp
in Series circuits in
Airfield lighting systems
The PCR 314 Dual Current Regulator is designed for use in airfield lightning systems that use
constant current up to 6,6Amp for power distribution to Information and Direction signs. The
unit contains a complete lamp ballast for 2x18W fluorescent TL tubes.
The PCR 314 presents a very high power factor seen by the Constant Current Regulator (CCR).
This contributes to a good power-factor for the entire system and lower operating
costs as result. The output 1 & 2 supply a 12Vdc, 50mA when the two TL tubes is Lighting.
Block diagram PCR314 Current Regulator
Schematic
EMI Current–
trans former
Rectifi er
Power switch
Inverter
Lamp fault detector
Lamp
network
Lamp
2x18W
Lamp OK. =
12Vdc
50mA
Lamp out
Up to 6,6Amps
PFC Controller
Technical information
Lifetime Hours vs Ambient Temp Cº
Temperature working
range
- 20 to + 65
Celsius Centigrade
Relative humidity
98% RH
Mechanical
dimension (mm)
Length 150 (175 overall)
Width 83 Height 47
Life time
According to graph
beside
Weight
900 grams
Casing
100 % plastic
with compound
Fluorescent tubes
2x18W
Storage temperature
range
- 20 to + 65
Celsius Centigrade
600000
Hours
500000
400000
Lif etimeH:
300000
200000
100000
0
25
30
40
50
60
70
Ambient Temp Cº
P.O. ADDRESS
Phone Switchboard:
Thörnbladsväg 6
S-386 90
Färjestaden
+46 485-56 39 00
SWEDEN
+46 485-358 05
Fax:
PCR314
Patent Pending
High Power factor State of
the art dual Current
Regulator for up to 6,6Amp
in Series circuits in Airfield
lighting systems
VA Consumption over Current
Note: The lowest input current to
get 100 % light output is 3,6Amps
@ 2,4mS on time out from
the CCR.
Volt Amperé (VA)
65,00
If the CCR on time is longer can the
input current be lower.
60,00
55,00
50,00
45,00
40,00
3,6
4,0
4,5
5,0
6,5
Primary Current (A rms)
Primary Voltage Drop
Power Factor over Current
0,97
Power Factor (PF)
Voltage (V rms)
12,00
11,50
11,00
10,50
10,00
9,50
9,00
0,92
0,87
0,82
0,77
3,6
4,0
4,5
5,0
6,5
Primary Current (A rms)
3,6
4,0
4,5
5,0
Primary Current (A rms)
Advantages
[High efficiency
[Low temperature rise
[Long life time
[High power factor
[Over voltage and over current
[Simple installation
[Constant tube light output
[Strikes a long life tube at least
[Output light comparable
[Moisture-proof
[Conforms to EMC standards
[Fire resistance class ULV0
P.O. ADDRESS
protected (100 Amps @ 30 sec)
20.000 times
Phone Switchboard:
Thörnbladsväg 6
S-386 90
Färjestaden
+46 485-56 39 00
SWEDEN
+46 485-358 05
Fax:
to a magnetic ballast
6,5
Updated: 2004-06-28
Schematic for PCR 314 with 1 Fluorescent tube connected to 100W TFO 6,6A/6,6A
6,6A/6,6A 100W
Tfo 1:1
RC Net
100nF+100R+33R
# 006-00037
Transient protection
# 001-00299
Within Sign
Red +
Blue
Yellow
R
Ballast PCR 314
V
R
Yellow
2 X 18 W
# 001-00314
Green +
Brown
Toroid transformer 230/15Vac (120Va)
# 041-00022
Lamp sensor
Lamp OK =
12Vdc
50mA
Fluorescent tube 18 W
Fluorescent tube 18 W
Ljussensor
Bild 4
Transformator
Bild 1
Centralenhet
Bild 2
Ljusbox
Bild 3