Snap-In Supercapacitors S501 Series, Snap-In, 2.7 V, 65ºC Overview Applications KEMET S501 Series Supercapacitors use a proprietary electrode design to deliver a very high power density. This product features high power performance of up to 350 F capacity in a single ended, board mountable, snap-in termination construction. Typical applications include automotive subsystems, backup power/UPS, handheld/portable devices, hybrid energy storage, hybrid drivetrains, windmill pitch control, emergency lighting, medical devices, power correction, engine starting, and renewable energy. Benefits • Board mountable •Solderable • High power • High rate cycling • Long life • Operating temperature range of -40˚C to +65˚C • High cycle life > 500,000 cycles • RoHS Compliant • Made in USA Part Number System S501 DC 107 V 2R7 A Series Size Code (D x L) Capacitance Code (µF) Capacitance Tolerance Rated Voltage (VDC) Termination Code First two digits represent significant figures. Third digit specifies number of zeros. V = -5/+10% W = -0/+20% 2R7 = 2.7 Supercapacitor, Snap-In Termination DC = 22 x 45 LF = 35 x 60 LI = 35 x 69 LR = 35 x 89 A = 2 pin, 10 mm lead spacing, 5.9 mm terminal length U = 4 pin standard snap-in style One world. One KEMET © KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com S6003_S501 • 12/29/2014 1 Snap-In Supercapacitors – S501 Series, Snap-In, 2.7 V, 65ºC Dimensions – Millimeters PCB Patterns 2- Ø 2 +/- 0.1 D S Negative Terminal Part Number LL L D L S LL Nominal Tolerance Nominal Tolerance Nominal Tolerance Nominal Tolerance S501DC107W2R7A 22 +1.0/-0 45 +/-2.0 10 +/-0.1 5.9 +/-1.0 S501LF357V2R7A 35 +1.0/-0 59 +/-2.0 10 +/-0.1 5.9 +/-1.0 S501LF357V2R7U 35 +0.6/-0.3 62 +/-1.0 23 +/-0.1 5.9 +/-1.0 © KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com S6003_S501 • 12/29/2014 2 Snap-In Supercapacitors – S501 Series, Snap-In, 2.7 V, 65ºC Performance Characteristics Item Performance Characteristics Rated Voltage 2.7 VDC Surge Voltage 2.85 VDC Capacitance Range Capacitance Tolerance 100 – 350 F -5/+10%; [100 F -0/+20%] Temperature Range -40°C to +65°C Storage Temperature Range -40°C to +70°C Life, DC Life, Endurance Life, Shelf Life, Cycle Standards Compliance 10 years, rated voltage, 25°C Δ C < 20% decrease, ESR < 100% increase 1,000 hours, rated voltage, 65°C Δ C < 20% decrease, ESR < 100% increase 1,000 hours, no voltage, 70°C Δ C < 20% decrease, ESR < 100% increase > 500,000 cycles, rated to half rated voltage, 25°C Δ C < 20% decrease, ESR < 100% increase RoHS, UL810a, BS EN 60068-2-6,27,29, IEC 60068-2-14, SAE J2464, J2390, J1455, ASTM B117, IP65, MIL–STD–810 B, Test Methods 516.3-5, 514.3-1, 509.2-1 Approvals Series Test Type Test Standard Date completed (or estimated) IEC 60068-2-6 Vibration S501 1 2 SAE J2380 ISO 16750-3 May 2013 Mechanical shock IEC 60068-2-27 Underwriters Laboratory UL-810A 1 by Partnumber SAE Safety And Abuse SAE J24645 2 pending 12/31/2013 UL-810A includes the following tests: Short Circuit, Abnormal Charge, Heating, Crush, Impact, Shock, Vibration SAE J2464 Includes the following tests: Nail Penetration, Crush, Thermal Stability, Thermal Shock, Short Ciruit, Overcharge, Forced Vent © KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com S6003_S501 • 12/29/2014 3 Snap-In Supercapacitors – S501 Series, Snap-In, 2.7 V, 65ºC Environmental Compliance All KEMET supercapacitors are RoHS Compliant. Table 1 – Ratings & Part Number Reference Part Number S501DC107W2R7A S501LF357V2R7A S501LF357V2R7U Electrical Capacitance (F) 100 350 350 -0/+20% -5/+10% -5/+10% Rated Voltage (V) 2.7 2.7 2.7 Surge Voltage (V) 2.85 2.85 2.85 ESR, DC ≤ (mΩ) [10ms] 4.2 3.2 2.7 ESR, AC 1 kHz ≤ (mΩ) 3.6 3.1 2.4 Inductance ±30 (nH) 120 150 150 72 Hour Leakage ≤ (mA) 0.27 1 1 Capacitance Tolerance Cycling Current, Peak [1s] (A) 95 223 243 Continuous Current (A)* 13 24 24 Current, Short Circuit (A) 643 844 750 11 10 Thermal Resistance, Thermal (°C/W) 22 Maximum Stored Energy (Wh) 0.1 0.35 0.35 Energy Density (Wh/kg) 5.1 5.4 5.4 Energy Density (Wh/L) 5.9 6.2 5.9 Power Density (kW/kg) 21.7 8.6 10.2 Power Density (kW/L) 25.5 10 11.2 Maximum Power (kW/kg) 10.4 4.1 4.9 Energy/Power Physical Case Size DC LF LF D x L (mm) 22 x 45 35 x 59 35 x 62 Weight (kg) 0.02 0.066 0.066 Volume (L) 0.017 0.057 0.06 Volume of ACN (L) 0.008 0.027 0.027 *Rated current = continuous current with 20°C temperature rise. © KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com S6003_S501 • 12/29/2014 4 Snap-In Supercapacitors – S501 Series, Snap-In, 2.7 V, 65ºC Mounting Do not scratch or file the lead terminals. The terminals are plated with metal and the removal of the plated material will cause poor solderability. Do not overheat when soldering. Solder temperature lower than 260°C and time shorter than 5 seconds are recommended. For hand soldering, tip temperature should be no higher than 350°C (662°F) for a maximum contact time of 3 seconds. Only the snap-in terminals should come into contact with liquid solder or iron. Excessive heat on the snap-in terminal boards can cause damage to seals, shrink sleeve, and electrodes resulting in shortened life or premature part failure. IMPORTANT! DO NOT DEFORM, PULL or TWIST the terminals. The terminals are attached to the electrodes in the interior of the aluminum casing and are tightly embedded in the rubber-plug sealing the casing. Repeated or forceful bending, pulling, or twisting of the terminal may create a path opening along the terminal in the rubber for electrolyte to leak out. The electrolyte leakage may not only shorten the useful life of the product, but it may also cause corrosion and/or short-circuit of neighboring circuitry. If deforming the terminal is unavoidable or essential to the assembly process, please use needle-nose pliers to bend the lead wire while holding the base of the same terminal using another needle-nose pliers so that the force applied to the wire is not transmitted to the rubber seal. KEMET recommends utilizing a PC board when connecting the cells to the circuit or electronic devices. In addition, avoid placing exothermic components near the supercapacitor or on the opposite side of the PC board. Please maintain a minimum distance of 3 mm between the bottom surface (opposite terminals) of the cell and other components/ housings in order to allow for unimpeded venting of gas through the safety vent. Packaging Quantities Part Number Capacitance (F) Rated Voltage S501DC107W2R7A 100 2.7 S501LF357V2R7A 350 2.7 S501LF357V2R7U 350 2.7 Package Type Box with Cardboard Separators Package Quantity Box Weight Box Length Box Width Box Height 128 7 lbs (3.2 kgs) 15.0" (381 mm) 8.0" (203 mm) 3.5" (89 mm) 50 8 lbs (3.7 kgs) 15.0" (381 mm) 8.0" (203 mm) 3.5" (89 mm) 50 9 lbs (4.1 kgs) 15.0" (381 mm) 8.0" (203 mm) 3.5" (89 mm) Standard Marking • KEMET logo • Rated capacitance • Rated voltage • Product number • Negative terminal marking • Energy in Wh © KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com S6003_S501 • 12/29/2014 5 Snap-In Supercapacitors – S501 Series, Snap-In, 2.7 V, 65ºC KEMET Corporation World Headquarters Europe Asia Southern Europe Sasso Marconi, Italy Tel: 39-051-939111 Northeast Asia Hong Kong Tel: 852-2305-1168 Mailing Address: P.O. Box 5928 Greenville, SC 29606 Skopje, Macedonia Tel: 389-2-55-14-623 Shenzhen, China Tel: 86-755-2518-1306 www.kemet.com Tel: 864-963-6300 Fax: 864-963-6521 Central Europe Landsberg, Germany Tel: 49-8191-3350800 Corporate Offices Fort Lauderdale, FL Tel: 954-766-2800 Kamen, Germany Tel: 49-2307-438110 North America Northern Europe Harlow, United Kingdom Tel: 44-1279-460122 Taipei, Taiwan Tel: 886-2-27528585 Espoo, Finland Tel: 358-9-5406-5000 Southeast Asia Singapore Tel: 65-6701-8033 2835 KEMET Way Simpsonville, SC 29681 Southeast Lake Mary, FL Tel: 407-855-8886 Northeast Wilmington, MA Tel: 978-658-1663 Central Novi, MI Tel: 248-306-9353 Beijing, China Tel: 86-10-5877-1075 Shanghai, China Tel: 86-21-6447-0707 Seoul, South Korea Tel: 82-2-6294-0550 Penang, Malaysia Tel: 60-4-6430200 Bangalore, India Tel: 91-806-53-76817 West Milpitas, CA Tel: 408-433-9950 Mexico Guadalajara, Jalisco Tel: 52-33-3123-2141 Note: KEMET reserves the right to modify minor details of internal and external construction at any time in the interest of product improvement. KEMET does not assume any responsibility for infringement that might result from the use of KEMET Capacitors in potential circuit designs. KEMET is a registered trademark of KEMET Electronics Corporation. © KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com S6003_S501 • 12/29/2014 6 Snap-In Supercapacitors – S501 Series, Snap-In, 2.7 V, 65ºC Disclaimer All product specifications, statements, information and data (collectively, the “Information”) in this datasheet are subject to change. The customer is responsible for checking and verifying the extent to which the Information contained in this publication is applicable to an order at the time the order is placed. All Information given herein is believed to be accurate and reliable, but it is presented without guarantee, warranty, or responsibility of any kind, expressed or implied. Statements of suitability for certain applications are based on KEMET Electronics Corporation’s (“KEMET”) knowledge of typical operating conditions for such applications, but are not intended to constitute – and KEMET specifically disclaims – any warranty concerning suitability for a specific customer application or use. The Information is intended for use only by customers who have the requisite experience and capability to determine the correct products for their application. Any technical advice inferred from this Information or otherwise provided by KEMET with reference to the use of KEMET’s products is given gratis, and KEMET assumes no obligation or liability for the advice given or results obtained. Although KEMET designs and manufactures its products to the most stringent quality and safety standards, given the current state of the art, isolated component failures may still occur. Accordingly, customer applications which require a high degree of reliability or safety should employ suitable designs or other safeguards (such as installation of protective circuitry or redundancies) in order to ensure that the failure of an electrical component does not result in a risk of personal injury or property damage. Although all product–related warnings, cautions and notes must be observed, the customer should not assume that all safety measures are indicted or that other measures may not be required. © KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com S6003_S501 • 12/29/2014 7