AC Line Filters SU Coils, SU 16VD High Frequency Type Overview Applications The KEMET SU Coils, SU 16VD High Frequency Type AC line filters are offered in a wide variety of sizes and specifications. • Consumer Electronics • Common mode choke Benefits • • • • Wide variety of sizes and specifications Inductances up to 50 µH Rated Currents up to 4 A DC Resistances as low as 0.04 Ω Part Number System SU 16 VD- 30 040 Series Core Size (mm) Core Orientation Rated Current (A) Minimum Inductance (µH) SU 16 = 16.0 VD- = Vertical x0 = x.0 A (e.g., 30 = 3.0 A) 0xx = xx µH (e.g., 040 = 40 µH) © KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com One world. One KEMET LF0021_SU16VD • 6/16/2014 1 AC Line Filters – SU Coils, SU 16VD High Frequency Type Dimensions – Millimeters 19 Maximum 10 27.5 Maximum 23 Maximum 13 ±0.5 4.0 Minimum ø0.7 10 ±0.5 13 Environmental Compliance All KEMET AC Line Filters are RoHS Compliant. Table 1 – Ratings & Part Number Reference Part Number Rated Current AC (A) Inductance (µH) Minimum DC Resistance/ Line (Ω) Maximum Temperature Rise (K) Maximum Marking Weight (g) Approximate SU16VD-30050 SU16VD-30040 SU16VD-30030 SU16VD-40020 SU16VD-40010 3.0 3.0 3.0 4.0 4.0 50 40 30 20 10 0.08 0.07 0.07 0.05 0.04 45 45 45 45 45 D30050 D30040 D30030 D40020 D40010 12.0 11.9 11.9 11.8 11.6 © KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com LF0021_SU16VD • 6/16/2014 2 ø0.7 4.0 min. 13±0.5 13 10±0.5 [mm] AC Line Filters – SU Coils, SU 16VD High Frequency Type umbering System Specifications Series Core size; shape (V: vertical) Ni-Zn ferrite core SU 16VD Rated current (30 stands for 3.0A) 250 VAC Inductance (050 stands for 50μH) U 16V D - 30 050 � � � � Item Rated Voltage Withstanding Voltage 2400 VAC (2 seconds, between lines) Insulation Resistance > 100 MΩ @ 500 VDC (between lines) Thermal Class E (120°C) Operating Temperature Range -25ºC to T (T = 120 - temperature rise) Inductance Measurement Condition 1 kHz, 1 V, KC530 Frequency characteristic Frequency Characteristics 1M 1 6 3 Impedance () 100K 1 6 3 10K 1 30050 6 3 30040 1K 1 30030 6 3 40020 100 1 6 3 40010 10 1 6 3 1 1K 3 6 1 10K 3 6 1 100K 3 6 1 1M Frequency (Hz) 3 6 1 10M 3 30M Notes on Use C Line Filters 2 Shelf Life • Use within 6 months. If the product is used after a storage period of 6 months or longer, confirm its solderability before use. Storage Condition • Avoid storage in high temperature and high humidity environment, as such condition may deteriorate the solderability of external electrode. • Avoid storage in atmosphere containing toxic gases or acid (e.g., sulphur and chlorine), as such gas may deteriorate the solderability of external electrode. • Avoid storage near strong magnetic field, as such condition may magnetize the product. © KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com LF0021_SU16VD • 6/16/2014 3 AC Line Filters – SU Coils, SU 16VD High Frequency Type KEMET Corporation World Headquarters Europe Asia Southern Europe Paris, France Tel: 33-1-4646-1006 Northeast Asia Hong Kong Tel: 852-2305-1168 Mailing Address: P.O. Box 5928 Greenville, SC 29606 Sasso Marconi, Italy Tel: 39-051-939111 Shenzhen, China Tel: 86-755-2518-1306 www.kemet.com Tel: 864-963-6300 Fax: 864-963-6521 Central Europe Landsberg,Germany Tel: 49-8191-3350800 Corporate Offices Fort Lauderdale, FL Tel: 954-766-2800 Kamen, Germany Tel: 49-2307-438110 North America Northern Europe Bishop’s Stortford, United Kingdom Tel: 44-1279-460122 2835 KEMET Way Simpsonville, SC 29681 Southeast Lake Mary, FL Tel: 407-855-8886 Espoo, Finland Tel: 358-9-5406-5000 Northeast Wilmington, MA Tel: 978-658-1663 Beijing, China Tel: 86-10-5829-1711 Shanghai, China Tel: 86-21-6447-0707 Taipei, Taiwan Tel: 886-2-27528585 Southeast Asia Singapore Tel: 65-6586-1900 Penang, Malaysia Tel: 60-4-6430200 Bangalore, India Tel: 91-806-53-76817 Central Novi, MI Tel: 248-306-9353 West Milpitas, CA Tel: 408-433-9950 Mexico Guadalajara, Jalisco Tel: 52-33-3123-2141 Note: KEMET reserves the right to modify minor details of internal and external construction at any time in the interest of product improvement. KEMET does not assume any responsibility for infringement that might result from the use of KEMET Capacitors in potential circuit designs. KEMET is a registered trademark of KEMET Electronics Corporation. © KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com LF0021_SU16VD • 6/16/2014 4 AC Line Filters – SU Coils, SU 16VD High Frequency Type Disclaimer ThisproducthasbeenmadeavailablethroughaPrivateLabelAgreementandaDevelopmentandCross-LicensingAgreementbetweenKEMETandNECTOKINtoexpandmarket andproductofferingsforbothcompaniesandtheirrespectivecustomers.Formoreinformation,pleasevisithttp://www.kemet.com/nectokin. Allproductspecifications,statements,informationanddata(collectively,the“Information”)inthisdatasheetaresubjecttochange.Thecustomerisresponsibleforcheckingand verifyingtheextenttowhichtheInformationcontainedinthispublicationisapplicabletoanorderatthetimetheorderisplaced. AllInformationgivenhereinisbelievedtobeaccurateandreliable,butitispresentedwithoutguarantee,warranty,orresponsibilityofanykind,expressedorimplied. StatementsofsuitabilityforcertainapplicationsarebasedonKEMETElectronicsCorporation’s(“KEMET”)knowledgeoftypicaloperatingconditionsforsuchapplications,butare notintendedtoconstitute–andKEMETspecificallydisclaims–anywarrantyconcerningsuitabilityforaspecificcustomerapplicationoruse.TheInformationisintendedforuseonly bycustomerswhohavetherequisiteexperienceandcapabilitytodeterminethecorrectproductsfortheirapplication.AnytechnicaladviceinferredfromthisInformationorotherwise providedbyKEMETwithreferencetotheuseofKEMET’sproductsisgivengratis,andKEMETassumesnoobligationorliabilityfortheadvicegivenorresultsobtained. Although KEMET designs and manufactures its products to the most stringent quality and safety standards, given the current state of the art, isolated component failures may still occur.Accordingly,customerapplicationswhichrequireahighdegreeofreliabilityorsafetyshouldemploysuitabledesignsorothersafeguards(suchasinstallationofprotective circuitry or redundancies) in order to ensure that the failure of an electrical component does not result in a risk of personal injury or property damage. Althoughallproduct–relatedwarnings,cautionsandnotesmustbeobserved,thecustomershouldnotassumethatallsafetymeasuresareindictedorthatothermeasuresmaynot berequired. © KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com LF0021_SU16VD • 6/16/2014 5