SU16VD-30030

AC Line Filters
SU Coils, SU 16VD High Frequency Type
Overview
Applications
The KEMET SU Coils, SU 16VD High Frequency Type AC line
filters are offered in a wide variety of sizes and specifications.
• Consumer Electronics
• Common mode choke
Benefits
•
•
•
•
Wide variety of sizes and specifications
Inductances up to 50 µH
Rated Currents up to 4 A
DC Resistances as low as 0.04 Ω
Part Number System
SU
16
VD-
30
040
Series
Core Size (mm)
Core Orientation
Rated Current (A)
Minimum Inductance (µH)
SU
16 = 16.0
VD- = Vertical
x0 = x.0 A (e.g., 30 = 3.0 A)
0xx = xx µH (e.g., 040 = 40 µH)
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com
One world. One KEMET
LF0021_SU16VD • 6/16/2014
1
AC Line Filters – SU Coils, SU 16VD High Frequency Type
Dimensions – Millimeters
19 Maximum
10
27.5 Maximum
23 Maximum
13 ±0.5
4.0 Minimum
ø0.7
10 ±0.5
13
Environmental Compliance
All KEMET AC Line Filters are RoHS Compliant.
Table 1 – Ratings & Part Number Reference
Part Number
Rated Current
AC (A)
Inductance
(µH)
Minimum
DC Resistance/
Line (Ω)
Maximum
Temperature
Rise (K)
Maximum
Marking
Weight (g)
Approximate
SU16VD-30050
SU16VD-30040
SU16VD-30030
SU16VD-40020
SU16VD-40010
3.0
3.0
3.0
4.0
4.0
50
40
30
20
10
0.08
0.07
0.07
0.05
0.04
45
45
45
45
45
D30050
D30040
D30030
D40020
D40010
12.0
11.9
11.9
11.8
11.6
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com
LF0021_SU16VD • 6/16/2014
2
ø0.7
4.0 min.
13±0.5
13
10±0.5
[mm]
AC Line Filters – SU Coils, SU 16VD High Frequency Type
umbering System
Specifications
Series
Core size; shape (V: vertical)
Ni-Zn ferrite core
SU 16VD
Rated current (30 stands for 3.0A)
250
VAC
Inductance (050 stands for 50μH)
U 16V D - 30 050
� �
�
�
Item
Rated Voltage
Withstanding Voltage
2400 VAC (2 seconds, between lines)
Insulation Resistance
> 100 MΩ @ 500 VDC (between lines)
Thermal Class
E (120°C)
Operating Temperature Range
-25ºC to T (T = 120 - temperature rise)
Inductance Measurement Condition
1 kHz, 1 V, KC530
Frequency
characteristic
Frequency
Characteristics
1M 1
6
3
Impedance ()
100K 1
6
3
10K 1
30050
6
3
30040
1K 1
30030
6
3
40020
100 1
6
3
40010
10 1
6
3
1
1K
3
6
1
10K
3
6
1
100K
3
6
1
1M
Frequency (Hz)
3
6
1
10M
3
30M
Notes on Use
C Line Filters
2
Shelf Life
• Use within 6 months. If the product is used after a storage period of 6 months or longer, confirm its solderability before use.
Storage Condition
• Avoid storage in high temperature and high humidity environment, as such condition may deteriorate the solderability of external
electrode.
• Avoid storage in atmosphere containing toxic gases or acid (e.g., sulphur and chlorine), as such gas may deteriorate the
solderability of external electrode.
• Avoid storage near strong magnetic field, as such condition may magnetize the product.
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com
LF0021_SU16VD • 6/16/2014
3
AC Line Filters – SU Coils, SU 16VD High Frequency Type
KEMET Corporation
World Headquarters
Europe
Asia
Southern Europe
Paris, France
Tel: 33-1-4646-1006
Northeast Asia
Hong Kong
Tel: 852-2305-1168
Mailing Address:
P.O. Box 5928
Greenville, SC 29606
Sasso Marconi, Italy
Tel: 39-051-939111
Shenzhen, China
Tel: 86-755-2518-1306
www.kemet.com
Tel: 864-963-6300
Fax: 864-963-6521
Central Europe
Landsberg,Germany
Tel: 49-8191-3350800
Corporate Offices
Fort Lauderdale, FL
Tel: 954-766-2800
Kamen, Germany
Tel: 49-2307-438110
North America
Northern Europe
Bishop’s Stortford, United Kingdom
Tel: 44-1279-460122
2835 KEMET Way
Simpsonville, SC 29681
Southeast
Lake Mary, FL
Tel: 407-855-8886
Espoo, Finland
Tel: 358-9-5406-5000
Northeast
Wilmington, MA
Tel: 978-658-1663
Beijing, China
Tel: 86-10-5829-1711
Shanghai, China
Tel: 86-21-6447-0707
Taipei, Taiwan
Tel: 886-2-27528585
Southeast Asia
Singapore
Tel: 65-6586-1900
Penang, Malaysia
Tel: 60-4-6430200
Bangalore, India
Tel: 91-806-53-76817
Central
Novi, MI
Tel: 248-306-9353
West
Milpitas, CA
Tel: 408-433-9950
Mexico
Guadalajara, Jalisco
Tel: 52-33-3123-2141
Note: KEMET reserves the right to modify minor details of internal and external construction at any time in the interest of product improvement. KEMET does not
assume any responsibility for infringement that might result from the use of KEMET Capacitors in potential circuit designs. KEMET is a registered trademark of
KEMET Electronics Corporation.
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com
LF0021_SU16VD • 6/16/2014
4
AC Line Filters – SU Coils, SU 16VD High Frequency Type
Disclaimer
ThisproducthasbeenmadeavailablethroughaPrivateLabelAgreementandaDevelopmentandCross-LicensingAgreementbetweenKEMETandNECTOKINtoexpandmarket
andproductofferingsforbothcompaniesandtheirrespectivecustomers.Formoreinformation,pleasevisithttp://www.kemet.com/nectokin.
Allproductspecifications,statements,informationanddata(collectively,the“Information”)inthisdatasheetaresubjecttochange.Thecustomerisresponsibleforcheckingand
verifyingtheextenttowhichtheInformationcontainedinthispublicationisapplicabletoanorderatthetimetheorderisplaced.
AllInformationgivenhereinisbelievedtobeaccurateandreliable,butitispresentedwithoutguarantee,warranty,orresponsibilityofanykind,expressedorimplied.
StatementsofsuitabilityforcertainapplicationsarebasedonKEMETElectronicsCorporation’s(“KEMET”)knowledgeoftypicaloperatingconditionsforsuchapplications,butare
notintendedtoconstitute–andKEMETspecificallydisclaims–anywarrantyconcerningsuitabilityforaspecificcustomerapplicationoruse.TheInformationisintendedforuseonly
bycustomerswhohavetherequisiteexperienceandcapabilitytodeterminethecorrectproductsfortheirapplication.AnytechnicaladviceinferredfromthisInformationorotherwise
providedbyKEMETwithreferencetotheuseofKEMET’sproductsisgivengratis,andKEMETassumesnoobligationorliabilityfortheadvicegivenorresultsobtained.
Although KEMET designs and manufactures its products to the most stringent quality and safety standards, given the current state of the art, isolated component failures may still
occur.Accordingly,customerapplicationswhichrequireahighdegreeofreliabilityorsafetyshouldemploysuitabledesignsorothersafeguards(suchasinstallationofprotective
circuitry or redundancies) in order to ensure that the failure of an electrical component does not result in a risk of personal injury or property damage.
Althoughallproduct–relatedwarnings,cautionsandnotesmustbeobserved,thecustomershouldnotassumethatallsafetymeasuresareindictedorthatothermeasuresmaynot
berequired.
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com
LF0021_SU16VD • 6/16/2014
5