SC Coils - Terminal Base Type SC-GJ Type

AC Line Filters
SC Coils, SC-GJ Terminal Base Type
Overview
Applications
The KEMET SC Coils, SC-GJ Terminal Base Type AC line filters
are offered in a wide variety of sizes and specifications.
• Consumer Electronics
• Common mode choke
Common mode
Benefits
– Terminal Base Type
•
•
•
•
e
Wide variety of sizes and specifications
Inductances up to 3.0 mH
Rated Currents up to 3 A
DC Resistances as low as 35 mΩ
ant]
DC resistance
Inductance
(m/line)
(mH)
max.
min.
80
2.0
Part3.0Number System100
35
0.6
SC40
1.0
Temperature
rise(K)
max.
40
40
40
02- 40
Rated Current (A)
Withstanding voltage:Series
AC 2400V (2 sec between
lines)
more than 100M(between
• Thermal
E (120˚C)
SC- lines)
0x- class:
= x A (e.g.,
02- = 2 A)
: –25 to T (T=120–temperature rise)
n:100kHz, 1mA, KC547
Wire size
(mmø)
0.5
0.5
0.6
0.6 30
Minimum Inductance (mH)
x0 = x.0 mH (e.g., 30 = 3.0 mH)
0x = 0.x mH (e.g., 06 = 0.6 mH)
Marking
220
230
306
310
Weight
approx.
(g)
9
10
8
GJ 9
Terminal Base Type
GJ
17 max.
(13)
5.0±2.0
(8.0)
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com
One world. One KEMET
LF0007_SC-GJ • 6/16/2014
1
AC Line Filters – SC Coils, SC-GJ Terminal Base Type
Dimensions – Millimeters
17.5 Maximum
17 Maximum
(8.0)
(13)
5.0 ±2.0
20 Maximum
Marking
(13)
(8.0)
Environmental Compliance
All KEMET AC Line Filters are RoHS Compliant.
Table 1 – Ratings & Part Number Reference
Part Number
Rated Current
AC (A)
Inductance
(mH)
Minimum
DC
Resistance/
Line (mΩ)
Maximum
SC-02-20GJ
SC-02-30GJ
SC-03-06GJ
SC-03-10GJ
2
2
3
3
2.0
3.0
0.6
1.0
80
100
35
40
Temperature
Wire Diameter
Rise (K)
(mm)
Maximum
40
40
40
40
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com
0.5
0.5
0.6
0.6
Marking
Weight (g)
Approximate
220
230
306
310
9
10
8
9
LF0007_SC-GJ • 6/16/2014
2
(1
5.0±
(13)
(8.0)
AC Line Filters – SC Coils, SC-GJ Terminal Base Type
[mm]
Specifications
Item
SC-GJ
Rated Voltage
250 VAC/VDC
Withstanding Voltage
2400 VAC (2 seconds, between lines)
Insulation Resistance
> 100 MΩ @ 500 VDC (between lines)
Thermal Class
E (120°C)
Operating Temperature Range
-25ºC to T (T = 120 - temperature rise)
Inductance Measurement Condition
100 kHz, 1 mA, KC547
Frequency Characteristics
equency characteristic
e Filters
1M
Impedance ()
100K
10K
1K
100
10
1
6
3
1
6
3
02-30GJ
1
6
3
02-20GJ
1
6
3
03-06GJ
1
6
3
1
6
3
1
1K
03-10GJ
3
6
1
10K
3
6
1
100K
3
6
1
1M
Frequency (Hz)
3
6
1
10M
3
30M
Notes on Use
Shelf Life
• Use within 6 months. If the product is used after a storage period of 6 months or longer, confirm its solderability before use.
Storage Condition
• Avoid storage in high temperature and high humidity environment, as such condition may deteriorate the solderability of external
electrode.
• Avoid storage in atmosphere containing toxic gases or acid (e.g., sulphur and chlorine), as such gas may deteriorate the
solderability of external electrode.
• Avoid storage near strong magnetic field, as such condition may magnetize the product.
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com
LF0007_SC-GJ • 6/16/2014
3
AC Line Filters – SC Coils, SC-GJ Terminal Base Type
KEMET Corporation
World Headquarters
Europe
Asia
Southern Europe
Paris, France
Tel: 33-1-4646-1006
Northeast Asia
Hong Kong
Tel: 852-2305-1168
Mailing Address:
P.O. Box 5928
Greenville, SC 29606
Sasso Marconi, Italy
Tel: 39-051-939111
Shenzhen, China
Tel: 86-755-2518-1306
www.kemet.com
Tel: 864-963-6300
Fax: 864-963-6521
Central Europe
Landsberg,Germany
Tel: 49-8191-3350800
Corporate Offices
Fort Lauderdale, FL
Tel: 954-766-2800
Kamen, Germany
Tel: 49-2307-438110
North America
Northern Europe
Bishop’s Stortford, United Kingdom
Tel: 44-1279-460122
2835 KEMET Way
Simpsonville, SC 29681
Southeast
Lake Mary, FL
Tel: 407-855-8886
Espoo, Finland
Tel: 358-9-5406-5000
Northeast
Wilmington, MA
Tel: 978-658-1663
Beijing, China
Tel: 86-10-5829-1711
Shanghai, China
Tel: 86-21-6447-0707
Taipei, Taiwan
Tel: 886-2-27528585
Southeast Asia
Singapore
Tel: 65-6586-1900
Penang, Malaysia
Tel: 60-4-6430200
Bangalore, India
Tel: 91-806-53-76817
Central
Novi, MI
Tel: 248-306-9353
West
Milpitas, CA
Tel: 408-433-9950
Mexico
Guadalajara, Jalisco
Tel: 52-33-3123-2141
Note: KEMET reserves the right to modify minor details of internal and external construction at any time in the interest of product improvement. KEMET does not
assume any responsibility for infringement that might result from the use of KEMET Capacitors in potential circuit designs. KEMET is a registered trademark of
KEMET Electronics Corporation.
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com
LF0007_SC-GJ • 6/16/2014
4
AC Line Filters – SC Coils, SC-GJ Terminal Base Type
Disclaimer
ThisproducthasbeenmadeavailablethroughaPrivateLabelAgreementandaDevelopmentandCross-LicensingAgreementbetweenKEMETandNECTOKINtoexpandmarket
andproductofferingsforbothcompaniesandtheirrespectivecustomers.Formoreinformation,pleasevisithttp://www.kemet.com/nectokin.
Allproductspecifications,statements,informationanddata(collectively,the“Information”)inthisdatasheetaresubjecttochange.Thecustomerisresponsibleforcheckingand
verifyingtheextenttowhichtheInformationcontainedinthispublicationisapplicabletoanorderatthetimetheorderisplaced.
AllInformationgivenhereinisbelievedtobeaccurateandreliable,butitispresentedwithoutguarantee,warranty,orresponsibilityofanykind,expressedorimplied.
StatementsofsuitabilityforcertainapplicationsarebasedonKEMETElectronicsCorporation’s(“KEMET”)knowledgeoftypicaloperatingconditionsforsuchapplications,butare
notintendedtoconstitute–andKEMETspecificallydisclaims–anywarrantyconcerningsuitabilityforaspecificcustomerapplicationoruse.TheInformationisintendedforuseonly
bycustomerswhohavetherequisiteexperienceandcapabilitytodeterminethecorrectproductsfortheirapplication.AnytechnicaladviceinferredfromthisInformationorotherwise
providedbyKEMETwithreferencetotheuseofKEMET’sproductsisgivengratis,andKEMETassumesnoobligationorliabilityfortheadvicegivenorresultsobtained.
AlthoughKEMETdesignsandmanufacturesitsproductstothemoststringentqualityandsafetystandards,giventhecurrentstateoftheart,isolatedcomponentfailuresmaystill
occur.Accordingly,customerapplicationswhichrequireahighdegreeofreliabilityorsafetyshouldemploysuitabledesignsorothersafeguards(suchasinstallationofprotective
circuitry or redundancies) in order to ensure that the failure of an electrical component does not result in a risk of personal injury or property damage.
Althoughallproduct–relatedwarnings,cautionsandnotesmustbeobserved,thecustomershouldnotassumethatallsafetymeasuresareindictedorthatothermeasuresmaynot
berequired.
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com
LF0007_SC-GJ • 6/16/2014
5