6MD-XD Series 6W, FIXED INPUT ISOLATED & REGULATED TWIN OUTPUT DIP24 DC-DC CONVERTER PRODUCT PROGRAM Input Part Output Efficiency Nomina Range Max* No-load Current (mA,Typ) 6MD120505XD l 12 10.8-13.2 15 25 5/5 600/600 60/60 76 FEATURES 6MD120707XD 12 10.8-13.2 15 25 7.2/7.2 417/417 42/42 79 6MD120909XD 12 10.8-13.2 15 25 9/9 333/333 33/33 78 ◆Fixed input voltage range 6MD121212XD 12 10.8-13.2 15 25 12/12 250/250 25/25 80 6MD121515XD 12 10.8-13.2 15 25 15/15 200/200 20/20 81 6MD122424XD 12 10.8-13.2 15 25 24/24 125/125 13/13 82 6MD240505XD 24 21.6-26.4 30 15 5/5 600/600 60/60 76 6MD240512XD 24 21.6-26.4 30 15 5/12 600/250 60/25 77 6MD241212XD 24 21.6-26.4 30 15 12/12 250/250 25/25 80 6MD241515XD 24 21.6-26.4 30 15 15/15 200/200 20/20 79 6MD242405XD 24 21.6-26.4 30 15 24/05 125/600 13/60 81 6MD242424XD 24 21.6-26.4 30 15 24/24 125/125 13/13 81 6MD480505XD 48 43.2-52.5 60 10 5/5 600/600 60/60 76 6MD480512XD 48 43.2-52.5 60 10 5/12 600/250 60/25 78 6MD480909XD 48 43.2-52.5 60 10 9/9 333/333 33/33 78 6MD481212XD 48 43.2-52.5 60 10 12/12 250/250 25/25 80 6MD481515XD 48 43.2-52.5 60 10 15/15 200/200 20/20 81 ◆ No heat sink required 6MD482424XD 48 43.2-52.5 60 10 24/24 125/125 13/13 82 ◆ RoHS Compliance *Input voltage can't exceed this value, or will cause the permanent damage. Number ◆Twin output ◆Operating temperature: -40℃ to + 85℃ ◆UL94-V0 package ◆No external component required ◆Industry standard pin out ◆Short circuit protection(automatic recovery) ◆ Five-sided metal shielding ◆ MTBF>1,000,000 hours Voltage(VDC) Voltage Current(MA) (VDC) Max Min. (%,Typ) MODEL SELECTION 6MD①12②05③05④X⑤ D⑥ ①Product Series ③1st Output Voltage ⑤Fixed Input Range ②Input Voltage ④2nd Output Voltage ⑥DIP24Package Style APPLICATIONS The 6MD-XD series are specially designed for applications where a wide range input voltage power supplies are isolated from the input power supply in a distributed power supply system on a circuit board. These products apply to: 1)Where the voltage of the input power supply is fixed voltage range; 2)Where isolation is necessary between input and output (Isolation Voltage≤1500VDC); 3)Where isolation is necessary between Vout1 and Vout2 (Isolation Voltage≤1000VDC); 4)Where the regulation of the output voltage and the output ripple noise are demanded. COMMON SPECIFICATIONS Item Test Conditions Min. Storage humidity Operating temperature -40 Storage Temperature -55 Temp. rise at full load PRODUCT ID DESCRIPTION Typ. Lead temperature Cooling Case Material Short circuit protection MTBF Max. Units 95 % 85 125 1.5mm from case for 10 seconds 300 Free Air Convection Plastic (UL94-V0) Continuous, Automatic Recovery 1000 Weight K hours 15 MICRODC R ESERVES THE COPYRIGHT http://www.microdc.cn ℃ 15 Technical Enquiries-Email:[email protected] Tel:0086-20-86000646 Page 1 of 3 g 6MD-XD Series TYPICAL CHARACTERISTICS ISOLATION SPECIFICATIONS Item Test Conditions Min. Isolation voltage Tested for 1 minute and 1mA max 1500 Isolation resistance Test at 500VDC 1000 Isolation capacitance Input/Output, 100KHz/1V Typ. Max. Units VDC MΩ 100 pF *Supply voltage must be discontinued at the end of short circuit duration. OUTPUT SPECIFICATIONS Item Test Conditions Min. Output power Refer to product program 0.6 Typ. Main output voltage accuracy Refer to recommended circuit Vice-output voltage accuracy Refer to recommended circuit ±3 ±5 Load regulation From 10% to 100% load ±0.5 ±1* ±0.2 ±1 Max. Units 6 W ±3 Line regulation Input voltage from low to high Temperature drift (Vout) Refer to recommended circuit Ripple** 20MHz Bandwidth 20 50 Noise** 20MHz Bandwidth 75 150 Switching frequency 100% load, input voltage range 300 % ±0.5 %/℃ ±0.03 mVp-p RECOMMENDED CIRCUIT KHz *Dual output models unbalanced load: ±5%. **Test ripple and noise by “parallel cable”method. See detailed operation instructions at Testing of Power Converter section, application notes. APPLICATION NOTE 1) Requirement On Output Load In order to ensure the product operate efficiently and reliably, in addition to a max load (namely full load), a minimum load is specified for this kind of DC/DC converter. Make sure the specified range of input voltage is not exceeded, the minimum output load no less than 10% load.If the actual load is less than the specified minimum load, the output ripple may increase sharply while its efficiency and reliability will reduce greatly. If the actual output power is very small, please add an appropriate resistor as extra loading, or contact our company for other lower output power products. 2) Recommended Circuit All the MD-XD Series have been tested according to the following recommended testing circuit before leaving factory. This series should be tested under load (see Figure 1). If you want to further decrease the input/output ripple,you can increase capacitance properly or choose capacitors with low ESR. However, the capacitance should not be too high, or may cause start-up problem. If you want to use the products in high EMI, please choose our metal packaged products. For every channel of output, provided the safe and reliable operation is ensured, the greatest capacitance of its filter capacitor sees (Table 1). General: Cin: 5V,12V 100µF 24V&48V 22µF/10µF Cout: 10µF/100mA EXTERNAL CAPACITOR TABLE (TABLE 1) 3) Input Current While using unstable power source, please ensure the output voltage and ripple voltage do not exceed indexes of the converter. The preceding power source must be able to provide for converter sufficient starting current Ip (Figure 2). General: Ip≤1.4*Iin-max 4) No parallel connection or plug and play http://www.microdc.cn Output External Capacitor Table (Table 1) Vout(VDC) Cout(uF) 5 680 9 470 12 330 15 220 24 100 Technical Enquiries-Email:[email protected] Tel:0086-20-86000646 Page 2 of 3 6MD-XD Series OUTLINE DIMENSIONS & FOOTPRINT DETAILS MECHANICAL DIMENSIONS RECOMMENDED FOOTPRINT(TOP VIEW) TUBE OUTLINE DIMENSIONS RoHS COMPLIANT INFORMATION Microdc Professional Power Module,Inc. Tel:0086-20-86000646 E-mail:[email protected] Website: www.microdc.cn This series is compatible with RoHS soldering systems with a peak wave solder temperature of 300°C for 10 seconds. The pin termination finish on the SIP package type is Tin Plate, Hot Dipped over Matte Tin with Nickel Preplate. The DIP types are Matte Tin over Nickel Preplate. Both types in this series are backward compatible with Sn/Pb soldering systems. REACH COMPLIANT INFORMATION This series has proven that this product does not contain harmful chemicals, it also has harmful chemical substances through the registration, inspection and approval. http://www.microdc.cn Technical Enquiries-Email:[email protected] Tel:0086-20-86000646 Page 3 of 3