MD-XD-6W Series

6MD-XD Series
6W, FIXED INPUT ISOLATED & REGULATED TWIN OUTPUT DIP24 DC-DC CONVERTER
PRODUCT PROGRAM
Input
Part
Output
Efficiency
Nomina
Range
Max*
No-load
Current
(mA,Typ)
6MD120505XD
l
12
10.8-13.2
15
25
5/5
600/600
60/60
76
FEATURES
6MD120707XD
12
10.8-13.2
15
25
7.2/7.2
417/417
42/42
79
6MD120909XD
12
10.8-13.2
15
25
9/9
333/333
33/33
78
◆Fixed input voltage range
6MD121212XD
12
10.8-13.2
15
25
12/12
250/250
25/25
80
6MD121515XD
12
10.8-13.2
15
25
15/15
200/200
20/20
81
6MD122424XD
12
10.8-13.2
15
25
24/24
125/125
13/13
82
6MD240505XD
24
21.6-26.4
30
15
5/5
600/600
60/60
76
6MD240512XD
24
21.6-26.4
30
15
5/12
600/250
60/25
77
6MD241212XD
24
21.6-26.4
30
15
12/12
250/250
25/25
80
6MD241515XD
24
21.6-26.4
30
15
15/15
200/200
20/20
79
6MD242405XD
24
21.6-26.4
30
15
24/05
125/600
13/60
81
6MD242424XD
24
21.6-26.4
30
15
24/24
125/125
13/13
81
6MD480505XD
48
43.2-52.5
60
10
5/5
600/600
60/60
76
6MD480512XD
48
43.2-52.5
60
10
5/12
600/250
60/25
78
6MD480909XD
48
43.2-52.5
60
10
9/9
333/333
33/33
78
6MD481212XD
48
43.2-52.5
60
10
12/12
250/250
25/25
80
6MD481515XD
48
43.2-52.5
60
10
15/15
200/200
20/20
81
◆ No heat sink required
6MD482424XD
48
43.2-52.5
60
10
24/24
125/125
13/13
82
◆ RoHS Compliance
*Input voltage can't exceed this value, or will cause the permanent damage.
Number
◆Twin output
◆Operating temperature: -40℃ to + 85℃
◆UL94-V0 package
◆No external component required
◆Industry standard pin out
◆Short circuit protection(automatic recovery)
◆ Five-sided metal shielding
◆ MTBF>1,000,000 hours
Voltage(VDC)
Voltage
Current(MA)
(VDC)
Max
Min.
(%,Typ)
MODEL SELECTION
6MD①12②05③05④X⑤ D⑥
①Product Series
③1st Output Voltage
⑤Fixed Input Range
②Input Voltage
④2nd Output Voltage
⑥DIP24Package Style
APPLICATIONS
The 6MD-XD series are specially designed for
applications where a wide range input voltage power
supplies are isolated from the input power supply in a
distributed power supply system on a circuit board.
These products apply to:
1)Where the voltage of the input power supply is fixed
voltage range;
2)Where isolation is necessary between input and
output (Isolation Voltage≤1500VDC);
3)Where isolation is necessary between Vout1 and
Vout2 (Isolation Voltage≤1000VDC);
4)Where the regulation of the output voltage and the
output ripple noise are demanded.
COMMON SPECIFICATIONS
Item
Test Conditions
Min.
Storage humidity
Operating temperature
-40
Storage Temperature
-55
Temp. rise at full load
PRODUCT ID DESCRIPTION
Typ.
Lead temperature
Cooling
Case Material
Short circuit protection
MTBF
Max.
Units
95
%
85
125
1.5mm from case for 10 seconds
300
Free Air Convection
Plastic (UL94-V0)
Continuous, Automatic Recovery
1000
Weight
K hours
15
MICRODC R ESERVES THE COPYRIGHT
http://www.microdc.cn
℃
15
Technical Enquiries-Email:[email protected] Tel:0086-20-86000646
Page 1 of 3
g
6MD-XD Series
TYPICAL CHARACTERISTICS
ISOLATION SPECIFICATIONS
Item
Test Conditions
Min.
Isolation voltage
Tested for 1 minute and 1mA max
1500
Isolation resistance
Test at 500VDC
1000
Isolation capacitance
Input/Output, 100KHz/1V
Typ.
Max.
Units
VDC
MΩ
100
pF
*Supply voltage must be discontinued at the end of short circuit duration.
OUTPUT SPECIFICATIONS
Item
Test Conditions
Min.
Output power
Refer to product program
0.6
Typ.
Main output voltage accuracy
Refer to recommended circuit
Vice-output voltage accuracy
Refer to recommended circuit
±3
±5
Load regulation
From 10% to 100% load
±0.5
±1*
±0.2
±1
Max.
Units
6
W
±3
Line regulation
Input voltage from low to high
Temperature drift (Vout)
Refer to recommended circuit
Ripple**
20MHz Bandwidth
20
50
Noise**
20MHz Bandwidth
75
150
Switching frequency
100% load, input voltage range
300
%
±0.5
%/℃
±0.03
mVp-p
RECOMMENDED CIRCUIT
KHz
*Dual output models unbalanced load: ±5%.
**Test ripple and noise by “parallel cable”method. See detailed operation instructions at Testing of Power
Converter section, application notes.
APPLICATION NOTE
1) Requirement On Output Load
In order to ensure the product operate efficiently and reliably, in addition to a max load (namely full load), a minimum
load is specified for this kind of DC/DC converter. Make sure the specified range of input voltage is not exceeded, the
minimum output load no less than 10% load.If the actual load is less than the specified minimum load, the output ripple may
increase sharply while its efficiency and reliability will reduce greatly. If the actual output power is very small, please add
an
appropriate resistor as extra loading, or contact our company for other lower output power products.
2) Recommended Circuit
All the MD-XD Series have been tested according to the following recommended testing circuit before leaving factory.
This series should be tested under load (see Figure 1).
If you want to further decrease the input/output ripple,you can increase capacitance properly or choose capacitors with
low ESR. However, the capacitance should not be too high, or may cause start-up problem. If you want to use the
products
in high EMI, please choose our metal packaged products. For every channel of output, provided the safe and reliable
operation is ensured, the greatest capacitance of its filter capacitor sees
(Table 1). General:
Cin:
5V,12V
100µF
24V&48V
22µF/10µF
Cout: 10µF/100mA
EXTERNAL CAPACITOR TABLE (TABLE 1)
3) Input Current
While using unstable power source, please ensure the output voltage and ripple voltage do not exceed indexes of the
converter. The preceding power source must be able to provide for converter sufficient starting current Ip (Figure 2).
General: Ip≤1.4*Iin-max
4) No parallel connection or plug and play
http://www.microdc.cn
Output External Capacitor Table (Table 1)
Vout(VDC)
Cout(uF)
5
680
9
470
12
330
15
220
24
100
Technical Enquiries-Email:[email protected] Tel:0086-20-86000646
Page 2 of 3
6MD-XD Series
OUTLINE DIMENSIONS & FOOTPRINT DETAILS
MECHANICAL DIMENSIONS
RECOMMENDED FOOTPRINT(TOP VIEW)
TUBE OUTLINE DIMENSIONS
RoHS COMPLIANT INFORMATION
Microdc Professional Power Module,Inc.
Tel:0086-20-86000646
E-mail:[email protected]
Website: www.microdc.cn
This series is compatible with RoHS soldering systems with a peak wave solder temperature
of 300°C for 10 seconds.
The pin termination finish on the SIP package type is Tin Plate, Hot Dipped over Matte Tin
with Nickel Preplate. The DIP types are Matte Tin over Nickel Preplate. Both types in this
series are backward compatible with Sn/Pb soldering systems.
REACH COMPLIANT INFORMATION
This series has proven that this product does not contain harmful chemicals, it also has
harmful chemical substances through the registration, inspection and approval.
http://www.microdc.cn
Technical Enquiries-Email:[email protected] Tel:0086-20-86000646
Page 3 of 3